Aortic Valve Disease Clinical Trial
Official title:
18F-GP1 Positron Emission Tomography-computed Tomography to Detect Bioprosthetic Aortic Valve Thrombosis; the Biothrombus Study.
18F-GP1 binds with high affinity to the glycoprotein IIb/IIIa receptors on activated platelets. 18F-GP1 PET-CT has recently demonstrated favourable safety, pharmacokinetic, biodistribution and diagnostic performance for the in vivo identification of venous and arterial thrombemboli.
Aortic stenosis is the most common reason for valvular interventions in the developed world, with rates projected to increase as the population ages. Aortic valve replacement remains the only recognised treatment available. Bioprostheses are far more common than mechanical prostheses, particularly with increasing rates of transcatheter heart valve use. Bioprothetic valves are less durable than mechanical valves and are subject to deterioration which may lead to clinical heart failure and the need for re-intervention. Long-term results with surgical bioprostheses are well reported, with valve deterioration rates of less than 15% at 10 years. These data, however, rely on re-operation rather than echocardiographic measures, suggesting that the true incidence of structural valve deterioration is underestimated. Valve thrombosis is increasingly recognised as a potential contributor to leaflet degeneration and has been detected in participants undergoing both surgical aortic valve replacement and transcatheter aortic valve implantation. The role of valve thrombosis as an early trigger for calcification and subsequent valve degeneration has not been addressed. The true incidence of valve thrombosis and its impact on clinical outcomes is unknown due to the lack of a sufficiently sensitive non-invasive imaging modality to detect early subclinical thrombosis. Current observational data suggests rates of 12 to 40%, based on computed tomography findings. There is a clinical need for a more sensitive non-invasive method of detecting valve thrombosis. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Recruiting |
NCT06001489 -
The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy
|
N/A | |
Not yet recruiting |
NCT04430972 -
Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
|
||
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Terminated |
NCT02128841 -
Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve.
|
Phase 2 | |
Active, not recruiting |
NCT01194362 -
A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
|
||
Not yet recruiting |
NCT05975567 -
Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
|
||
Recruiting |
NCT06025149 -
The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
|
||
Completed |
NCT05082337 -
The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures
|
N/A | |
Completed |
NCT05193760 -
Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
|
||
Not yet recruiting |
NCT05941455 -
A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve
|
N/A | |
Active, not recruiting |
NCT04950192 -
Philips Intracardiac Echocardiography (ICE) Clinical Registry
|
||
Active, not recruiting |
NCT03924661 -
SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
|
||
Recruiting |
NCT03121053 -
Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement
|
Phase 4 | |
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Completed |
NCT02981004 -
PAR I - Patient-to-Annulus Relation I
|
||
Completed |
NCT02688153 -
EDWARDS INTUITY Valve System CADENCE Study
|
N/A | |
Recruiting |
NCT06126367 -
Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease
|
||
Active, not recruiting |
NCT05082454 -
Post Market Clinical Follow-Up Study in Patients Treated With the On-X Ascending Aortic Prosthesis (AAP)
|