Clinical Trials Logo

Clinical Trial Summary

This study aimed at comparing the performance of self-expandable valves versus balloon-expandable valves in patients with ascending aortic dilation undergoing transcatheter aortic valve replacement.


Clinical Trial Description

Ascending aortic (AA) dilation is a common feature in patients with aortic stenosis (AS), especially in those with bicuspid aortic valve (BAV). For patients undergoing surgical aortic valve replacement (SAVR), current guidelines recommend concomitant aortic repair or replacement if the diameter of AA exceeds 45mm to avoid aortic dissection or rupture. Transcatheter aortic valve replacement (TAVR) has profoundly changed the clinical management of AS patients who cannot tolerate SAVR. For patients who are candidates for TAVR, simultaneous repair of a dilated AA can be technically difficult. The safety and feasibility of the procedure and the fate of AA after the procedure in these patients remain unclear. Moreover, there are limited data comparing the performance of self-expandable valves versus balloon-expandable valves in these patients. The aim of the present study is to evaluate the impact of type of transcatheter heart valves on intra-procedural device success and post-procedural AA progression in patients with dilated AA (≥45mm) undergoing TAVR. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06009588
Study type Interventional
Source China National Center for Cardiovascular Diseases
Contact
Status Active, not recruiting
Phase N/A
Start date July 12, 2023
Completion date July 11, 2026

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Completed NCT03332745 - Mechanism of Decompensation Evaluation - Aortic Stenosis
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A