Clinical Trials Logo

Clinical Trial Summary

Aortic insufficiency (IA) is defined as an abnormal regurgitation of blood from the aorta to the left ventricle in diastole, due to a lack of tightness of the aortic valves. It represents about 10% of valvular pathologies but the annual mortality of nonoperated patients can be as high as 10% to 20%. The quantification of AI is therefore important as it can remain perfectly asymptomatic for a long time. Doppler echocardiography is currently the key examination to confirm the presence of valvulopathy, to allow positive diagnosis of valve leakage regardless of location, to specify the etiology and mechanism of regurgitation. The quantification of IA requires, in transthoracic ultrasound, to take into account many parameters that individually have all certain limitations. The recommendations are therefore to have an integrative approach considering a combination of different parameters and an overall interpretation. This makes it possible to evaluate with greater precision the importance of the leak. Thus, there is the difficulty of quantifying moderate and severe AI for lack of a truly unique criterion. One of the evaluation criteria commonly used in transthoracic ultrasound is diastolic regurgitation in the aortic arch but this assessment is sometimes difficult. The left subclavian artery (SCG) is more accessible than the aortic arch in terms of the ultrasound window. The measurements will be easier to record since the vessel is more superficial and there are fewer air interpositions than for the aortic arch. The quantification of the AI based on this new element will be compared to the other previously validated ultrasound criteria. The investigators will use this study to describe the feasibility of collecting coronary flow in the artery (IVA), and they will compare systolic velocity, diastolic rate / systolic rate ratio compared to a control group without severe aortic insufficiency (grades 2 and 3). The flows recorded in the IVA will be compared to the importance of the aortic leakage according to its different modes of quantification (ultrasound and MRI). The aim of the study will be to show that diastolic reflux in the left subclavian artery is a marker of severe AI (grades 2 and 3) by comparing this regurgitation with that measured at the level of the aortic arch and other validated ultrasound criteria and cardiac MRI.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03549091
Study type Interventional
Source Groupe Hospitalier Paris Saint Joseph
Contact
Status Active, not recruiting
Phase N/A
Start date May 4, 2018
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT03666351 - Study to Evaluate the Effect on Improvement of LVH by the Control of BP in Hypertension Patients With AV Disease Phase 4
Recruiting NCT06034028 - J-Valve TF Early Feasibility Study N/A
Completed NCT05515848 - Aortic Valve-sparing Root Replacement, According to the Inclusion Technique Described by Tirone David
Completed NCT01598844 - JUPITER Study: Transapical Aortic Valve Implantation for Aortic Regurgitation
Active, not recruiting NCT03466918 - China S3: Safety and Effectiveness of Edwards Lifesciences SAPIEN 3 THV in the Chinese Population N/A
Active, not recruiting NCT04415047 - The JenaValve ALIGN-AR Pivotal Trial N/A
Not yet recruiting NCT05319171 - Performance of Currently Available traNscaTHEter Aortic Valve Platforms in Inoperable Patients With Pure Aortic regurgitatiON of a Native Valve. The PANTHEON International Project.
Completed NCT05774795 - LOng-Term Fate of Moderate Aortic Regurgitation Left Untreated at the Time of Mitral Valve Surgery
Terminated NCT02351726 - Mitroflow DL Post Approval Study- North America N/A
Completed NCT00624884 - Velocity Vector Imaging in Patients With Moderate-to-Severe Aortic Regurgitation N/A
Withdrawn NCT05409378 - HLT® Meridian® TAVR Valve System Early Feasibility Study for Aortic Regurgitation N/A
Recruiting NCT04038879 - Comparison Study of Echocardiography and Cardiovascular Magnetic Resonance Imaging in the Assessment of Mitral and Aortic Regurgitation
Completed NCT05332184 - Cardiac T1 Mapping Enables Risk Prediction of LV Dysfunction After Surgery for Aortic Regurgitation
Completed NCT01400841 - HAART Model 300 Annuloplasty Ring N/A
Not yet recruiting NCT02633423 - Expiratory Flow Limitation and Mechanical Ventilation During Cardiopulmonary Bypass in Cardiac Surgery N/A
Completed NCT00976625 - Diastolic Dysfunction in Aortic Regurgitation N/A
Enrolling by invitation NCT05714293 - CT-evaluation of Coronary Ostia Height After Surgical Aortic Valve Replacement. N/A
Recruiting NCT02974920 - Rivaroxaban or Aspirin for Biological Aortic Prosthesis Phase 4
Not yet recruiting NCT03788590 - Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System N/A