Aortic Aneurysm Clinical Trial
— RelayBranchOfficial title:
A Prospective, Multicenter, Non-Blinded, Non-Randomized Early Feasibility Study of the Relay Branch Thoracic Stent-Graft System in Subjects With Thoracic Aortic Pathologies Requiring Treatment Proximal to the Origin of the Innominate Artery
Verified date | August 2023 |
Source | Bolton Medical |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of this study is to conduct an early clinical evaluation of the Relay Branch System, which will provide initial insight into the clinical safety and function of the device. This Early Feasibility Study (EFS) will assess the safety and effectiveness of the device at the index procedure and at 30-day follow-up. The study will evaluate the delivery and deployment of the device, patency of branches and branch vessels, and exclusion of the aortic pathology. The data will help determine if modifications need to be made to the device, the procedural steps, operator technique, or the indications for use.
Status | Active, not recruiting |
Enrollment | 30 |
Est. completion date | August 31, 2028 |
Est. primary completion date | September 18, 2023 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Age =18 years - Anatomy that would require coverage of the brachiocephalic trunk (BCT) and/or left carotid arteries if a non-branch endograft were implanted - At least one of the following: a. Aneurysm of the ascending aorta, aortic arch, or proximal descending aorta that meets at least one of the following: i. = 5.5 cm in diameter ii. = 4.0 cm in diameter that has increased in size by 0.5 cm in the last 6 months iii. Measures twice the size of the normal aorta diameter iv. Is saccular in configuration b. PAU within the ascending aorta, aortic arch, or proximal descending thoracic aorta (DTA) with or without intramural hematoma (IMH) c. Chronic, uncomplicated aortic dissection distal to the BCT (type B), with either aortic diameter =5.5 cm or =4.0 cm with an increase in size by 0.5 cm in the last 6 months d. IMH distal to the BCT with recurrent symptoms, i.e. hypertension or intractable pain, despite best medical therapy. - A non-aneurysmal proximal aortic neck diameter ranging between 28 mm and 43 mm and a non-aneurysmal distal aortic neck diameter ranging between 19 mm and 43 mm. - A proximal attachment zone of the arch graft, meeting the oversizing requirement, must be a minimum of 25mm in length when measured on the inner curve of the ascending aorta, proximal to the BCT. - Total length from the coronaries to the proximal edge of the BCT must be a minimum of 70mm. - The length of the distal landing zone should be 20mm minimum. - Coverage of the left subclavian artery is permitted. Revascularization of the left subclavian artery may be considered in all cases by the treating physician and, especially, in anatomies where revascularization is determined to be clinically necessary - The distal landing zone must contain a straight segment (non-tapered, non-reverse tapered; defined by < 10% diameter change) with length equal to or greater than the required attachment length of the intended device - Non-aneurysmal BCT and left common carotid arteries with diameters ranging > 6.0mm across the entire length of the treatment zone. - Distal branch landing zone must be <20.0 mm in diameter and a minimum of 25.0 mm in length. - Adequate arterial access for introduction and delivery of the Relay Branch System. Note: Alternative methods to gain proper access can be utilized (e.g., iliac conduit) - Considered high risk or prohibitive risk for conventional surgery by treating physician or aortic team - Must be willing to comply with the follow-up evaluation schedule - Subject or legally authorized representative must sign the informed consent form prior to implant. Exclusion Criteria: - Significant stenosis, calcification, thrombus, or tortuosity of intended fixation sites that would compromise fixation or seal of the device - Aortic angulations (radius) less than 15mm at intended proximal landing zone. - Ascending aortas that would require the arch graft to be deployed less than 15mm distal to the coronaries - Pre-procedure occlusion or planned coverage of both subclavian arteries - Anatomic variants which would compromise circulation to both vertebral arteries after placement of the stent-graft - Prior endovascular repair in the ascending/descending thoracic aorta or aortic arch. The device may not be placed within any prior endovascular graft - Concomitant aneurysm/disease of the abdominal aorta requiring repair - Prior abdominal aortic aneurysm repair (endovascular or surgical) that was performed less than 6 months prior to the planned stent implant procedure - Prior mechanical aortic valve replacement except for hybrid valves with biological leaflets. - Major surgical or medical procedure within 45 days prior to the planned procedure or is scheduled for a major surgical or medical procedure within 60 days post implantation. Except for any planned procedures for the prospective stent-graft placement, e.g., left subclavian artery bypass or transposition - Untreatable allergy or sensitivity to contrast media or device components - Blood coagulation disorder or bleeding diathesis in which the treatment cannot be suspended for one week pre and post repair - Acute Coronary Syndrome (ACS) including unstable angina - Severe Congestive Heart Failure (New York Heart Association functional class IV) - Stroke within 12 months of the planned treatment date - Myocardial infarction within 3 months of the planned treatment date. - Chronic atrial fibrillation or other hypercoagulable condition that requires treatment with anticoagulants or presence of left atrial appendage thrombus - Severe pulmonary disease (documented FEVI <30% or as assessed by the study physician) at screening - Acute renal failure (defined as serum creatinine > 2.5mg/dL Note: Patients that have chronic renal failure and are managed medically or through hemodialysis, and can tolerate the follow-up imaging schedule can be included. - Significant carotid bifurcation disease (>70% diameter reduction by duplex ultrasound or angiography) - Hemodynamic instability - Active systemic infection at the time of treatment - Morbid obesity or other condition that may compromise or prevent the necessary imaging requirements - Connective tissue disorders, mycotic aneurysms, or infected aorta - Less than two-year life expectancy - Current or planned participation in an investigational drug or device study that has not completed primary endpoint evaluation - Currently pregnant or planning to become pregnant during the course of the study - Medical, social, or psychological issues that the Investigator believes may interfere with treatment or follow-up |
Country | Name | City | State |
---|---|---|---|
United States | Emory University | Atlanta | Georgia |
United States | University of Maryland | Baltimore | Maryland |
United States | Massachusetts General Hospital | Boston | Massachusetts |
United States | Cleveland Clinic | Cleveland | Ohio |
United States | Duke University | Durham | North Carolina |
United States | University of Florida | Gainesville | Florida |
United States | Baylor College of Medicine | Houston | Texas |
United States | University of Southern California | Los Angeles | California |
United States | Columbia University Medical Center | New York | New York |
United States | Hospital of the University of Pennsylvania/Penn Presbyterian | Philadelphia | Pennsylvania |
United States | Baylor Scott and White Research Institute | Plano | Texas |
United States | Barnes Jewish Hospital at Washington University | Saint Louis | Missouri |
Lead Sponsor | Collaborator |
---|---|
Bolton Medical |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Composite of Major Adverse Events (MAEs) | The primary safety outcome determined by the rate of MAEs, including
All-cause mortality Disabling stroke: a Modified Rankin Score (mRS) of 2 or more at 90 days and an increase in at least one mRS category from an individual's pre-stroke baseline Permanent Paralysis/Paraparesis Spontaneous Myocardial Infarction according to the SCAI definition Renal Failure Procedural Blood Loss >1,000mL |
30 days after the index procedure | |
Secondary | Composite of the following Criteria | Acute technical success evaluation, beginning with the insertion of the introducer sheath and as a composite of the following:
Success is defined as a successful delivery of the device through (i.e. ability to deliver the implant to the intended implantation site, without the need for unanticipated corrective intervention related to delivery): Successful deployment of the device as defined as i. Deployment of the endovascular stent-graft at the intended implantation site; ii. Patency (<50%) of all components of the implant with absence of device deformations requiring unplanned placement of an additional device within the endovascular stent-graft; and iii. absence of inadvertent covering of aortic branch vessels; and c. Successful withdrawal of the delivery system Patency of all endograft components at 30 days |
Technical success will be evaluated in 2 stages; the first evaluation occurs during the implant procedure. Technical success is then re-evaluated again 30 days post operation to ensure the graft placement was successful as outlined above |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Enrolling by invitation |
NCT04035356 -
HAART Annuloplasty Device Valve Repair Registry
|
||
Recruiting |
NCT02729064 -
Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose
|
Phase 1 | |
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Completed |
NCT02283307 -
Dual Energy CT Urography With Reduced Iodinated Contrast
|
N/A | |
Completed |
NCT01678261 -
X-chromosome Inactivation, Epigenetics and the Transcriptome
|
N/A | |
Terminated |
NCT01055275 -
Cook Iliac Branch Graft Post-market Registry
|
N/A | |
Completed |
NCT00615888 -
Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair
|
N/A | |
Completed |
NCT03510793 -
Microcirculation and Anesthesia in Vascular Surgery
|
||
Completed |
NCT03207568 -
RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU)
|
N/A | |
Recruiting |
NCT05073991 -
Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
|
||
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Not yet recruiting |
NCT01918969 -
Reference Values of Circulating Endothelial Progenitor Cells
|
N/A | |
Not yet recruiting |
NCT01918982 -
Circulating Endothelial Progenitor Cells and Aortic Aneurysm
|
N/A | |
Completed |
NCT01256372 -
An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery
|
Phase 2 | |
Recruiting |
NCT00661518 -
PET/CT Imaging of Aneurysm Wall Inflammation
|
N/A | |
Completed |
NCT00094575 -
Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA)
|
Phase 4 | |
Recruiting |
NCT04471909 -
NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness
|
N/A | |
Recruiting |
NCT05603520 -
Phenotyping Heterogeneity and Regionality of the Aorta
|
||
Completed |
NCT03727542 -
Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels
|
N/A |