Clinical Trials Logo

Clinical Trial Summary

Reducing the risk of perioperative cardiovascular complications is a major issue for anesthesiology practice and research. Carotid-Femoral Pulse Wave Velocity (PWVcf)is a predictive, early and independent biomarker of cardiovascular events. Despite the unanimous support for PWVcf, it has not been widely used in routine clinical practice because of the complexity of the measurement method. Our team has developed a method to estimate PWVcf continuously in the operating room from the data obtained by the usual monitoring: an electrocardiogram (ECG), a digital photoplethysmography (PPG) and an oscillometric brachial sphygmomanometer for non-invasive blood pressure measurement (NIP). The objective of this study is to validate, during anesthesia, the method of estimation of PWV (obtained using the usual monitoring tools including the parameters derived from the SpO2 signal, NIBP and ECG) by comparing it to the reference method by measuring the carotid-femoral transit time obtained by Doppler effect. The measurement of the carotid-femoral transit time obtained by Doppler effect is totally non-invasive.


Clinical Trial Description

Reducing the risk of perioperative cardiovascular complications is a major issue for anesthesiology practice and research. The risk of postoperative cardiovascular complications could therefore be stratified by screening "rigid" patients who have no cardiovascular risk factors. Assessment of large-caliber artery stiffness is a predictive, early, and independent biomarker of cardiovascular events, currently included in European guidelines for the management of hypertension. It is also a physiological parameter that reflects left ventricular afterload and is very useful during the management of patients under general anesthesia. The parameter considered as the "gold standard" for the evaluation of this arterial stiffness is the measurement of the pulse wave velocity (PWV) or carotid-femoral pulse wave velocity (PWVcf). PWVcf is the propagation speed of the pulse wave from the carotid artery to the femoral artery, i.e., the time it takes for the pulse wave to travel from a point in the carotid artery to a point in the femoral artery. PWVcf has not become widespread in routine clinical practice because of the complexity of the measurement method. Indeed, PWVcf measurement can only be performed by imaging (MRI), or by ultrasound technique (combined carotid and femoral Doppler) or by combined tonometry (e.g. SphygmoCor, Complior). These techniques require specific equipment as well as training, expertise and learning of the collection technique. Previous studies have allowed the development of an algorithm allowing indirect measurement of PWV from combined carotid-femoral Doppler and tonometry PWVcf measurements in patients under general anesthesia. Thanks to the acquisition tools, the data will be available and of high quality, guaranteeing that the tools/algorithm developed from them will not be biased and will be more efficient. The objective of this study is to validate, during anesthesia, the method of estimation of PWV (obtained using the usual monitoring tools including the parameters derived from the SpO2 signal, NIBP and ECG) by comparing it to the reference method by measuring the carotid-femoral transit time obtained by Doppler effect. Patients over 18 years old are eligible to participate in this protocol. During the anaesthesia consultation, patients will be given a letter of information on the objectives and progress of the study. Their non-objection to participate in this study will be collected at the latest during the pre-anesthetic visit, the day before the operation, after a period of reflection. The protocol will start on the day of the operation. The procedures will be performed under general anesthesia or locoregional anesthesia. The protocol does not interact with the care procedure. The 2 self-adhesive Doppler sensors are placed at the level of the common carotid and superficial femoral arteries at the level of the Scarpa. The visualized signal is automatically validated after several cycles when the quality is satisfactory (Athys Medical©) - WAKIe R3 2TC®). This signal, allowing the measurement of the carotid-femoral transit time, is then recorded on Data Warehouse Connect. The distance between the two measurement points is measured with a tape measure. Knowing the carotid-femoral transit time, the propagation speed of the wave (expressed in m/s) can be calculated. No invasive devices are used in addition to those required for anesthesia. All the monitoring instruments described above, except the one studied, are already used routinely in our department. The duration of anesthesia is not prolonged for the study. The Doppler is performed during the awake, anesthetic induction and awake phase. No additional exams will be performed. The anesthetic strategy is decided by the anesthesiologist in charge of the operation. The physician in charge of the study collecting the data does not participate at any time in the management of the patient. The measures cannot influence the prescribing physician since at this stage the data are not yet analyzed and available The estimation of the number of subjects to be included is based on the primary endpoint, namely the intraclass correlation coefficient. Thus, to demonstrate an ICC of 0.9 with a confidence interval of 0.1, for a 5% alpha risk, it is necessary to include 98 patients. Continuous data are expressed as median [interquartile] and categorical data as n (%). Categorical variables will be compared by Mann-Whtney test and continuous variables by Wilcoxon test. The agreement between the two methods will be evaluated by the intra-class correlation coefficient as well as by the Bland-Altman representation (with determination of the bias and the limits of agreement), for the different parameters of interest. All statistical analyses will be performed using R statistical software (The 'R' Foundation for Statistical Computing, Vienna, Austria). The results will be expressed as means (± standard deviation). A p-value less than 0.05 is considered significant ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05654402
Study type Observational
Source Assistance Publique - Hôpitaux de Paris
Contact Joaquim MD MATEO
Phone +33 (0)149958374
Email joaquim.mateo@aphp.fr
Status Recruiting
Phase
Start date February 10, 2023
Completion date August 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas