Clinical Trial Summary

In low-resource areas of the world, anemia screening relies on analyzing a blood sample and is generally carried out in health facilities. Current anemia screening approaches have not yielded satisfactory results due to critical limitations including lack of a) reliable access to laboratory facilities, b) reliable non-invasive out-of-hospital screening tools for community health-workers, c) integration of anemia data across health systems and d) distinction between hemolytic and nutritional causes. Currently available non-invasive tools have unacceptably low accuracy and cannot distinguish between nutritional and hemolytic etiologies. Prototype Anemia Diagnostic Assistant (ADA) We have developed a prototype Anemia Diagnostic Assistant for non-invasive, simultaneous detection of two markers of anemia, blood hemoglobin and the End-Tidal carbon monoxide levels. The device comprises an optical sensor module and ETCO breath sampling module. The unique and significant advantage of the instrument is its ability to detect, independently, two orthogonal variables that are required for differential diagnosis of the nutritional and hemolytic anemia: 1. Hemoglobin concentration using a non-invasive diffuse reflectance spectroscopy. Using high-fidelity, 11 wave-length spectral sensor, the device will provide optical quantification of hemoglobin levels. Optical hemoglobin sensing using diffused reflectance spectroscopy is well known, however; using traditional spectrophotometry instrumentation is very costly and thus impractical for this project. As a solution, we propose to use a validated commercially-available high accuracy 11-wavelength sensor within the visual and near-infrared (IR) range of the spectrum. The 11-wavelength spectrum will allow for sufficient accuracy in measuring the reflectance AND transmittance at isosbestic wavelengths on hemoglobin extinction curve as well as to compensate for the presence of melanin, which is a major interferant in optical determination of hemoglobin concentration. [9] The sensor was originally designed to collect data on the earlobe and/or the fingertip. Additional iterations include a sensor that straps around the wrist (similar to a smartwatch). Both versions of the device may be used in the study, and both feature standard USB or Bluetooth connectivity to ubiquitous mobile Android an iOS-based mobile platform . 2. End-tidal carbon monoxide. Using a non-invasive probe placed in proximity to the nostrils, the device will measure ETCO as a proxy measure of hemolysis. ETCO measurement as a measure for the presence of hemolysis is well documented in the medical literature and is commonly used in newborns units as a screening method for the presence of hemolysis [7,8,10]. A positive finding (presence of elevated levels of ETCO) will then prompt a referral for further hospital testing. The objective of this study is to determine the hemoglobin and ETCO concentration in healthy volunteers using the prototype device and compare the results with the hemoglobin and ETCO concentrations obtained using standard of care devices and the CoSense system for the (ETCO measurement).


Recruitment information / eligibility

Status Recruiting
Enrollment 25
Est. completion date December 2024
Est. primary completion date May 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 17 Years to 70 Years
Eligibility Inclusion Criteria: - Healthy adult Exclusion Criteria: - Immunocompromised subjects - Patients with known hemolytic disease, anemia, or other chronic illness - Patients who do not provide consent. - Those who are students or reporting staff of investigators will be excluded.

Study Design


Related Conditions & MeSH terms


Intervention

Diagnostic Test:
Anemia Diagnostic Assistant (ADA)
The Anemia Diagnostic Assistant is non-invasive and simultaneously detects two markers of anemia, blood hemoglobin and the End-Tidal carbon monoxide levels. The device comprises an optical sensor module and ETCO breath sampling module.
Serum hemoglobin
Venous blood will be drawn on the same day as the ADA was applied and sent to the hospital lab for hemoglobin analysis.

Locations

Country Name City State
United States University of Utah Salt Lake City Utah

Sponsors (1)

Lead Sponsor Collaborator
University of Utah

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Difference in ADA hemoglobin values compared to serum hemoglobin values Each participant will have their hemoglobin measured using the ADA and blood analysis. These values will then be compared to measure the difference between the ADA values and the serum values. 24 hours
Secondary Incidence of hemolytic anemia The ETCO is a well established measure of hemolysis. The study will evaluate the number of positive readings and individual participants who have a positive measure will be referred for further hospital testing. 24 hours
See also
  Status Clinical Trial Phase
Terminated NCT00801931 - Double Cord Blood Transplant for Patients With Malignant and Non-malignant Disorders Phase 1/Phase 2
Completed NCT02948283 - Metformin Hydrochloride and Ritonavir in Treating Patients With Relapsed or Refractory Multiple Myeloma or Chronic Lymphocytic Leukemia Phase 1
Completed NCT03341338 - Genes-in-Action - Hepcidin Regulation of Iron Supplementation
Completed NCT00060398 - Epoetin Alfa With or Without Dexamethasone in Treating Fatigue and Anemia in Patients With Hormone-Refractory Prostate Cancer Phase 3
Recruiting NCT05384691 - Efficacy of Luspatercept in ESA-naive LR-MDS Patients With or Without Ring Sideroblasts Who do Not Require Transfusions Phase 2
Not yet recruiting NCT06309641 - Methemoglobinemia Following Intravenous Iron Treatment
Completed NCT02912533 - A Long-term Study of JR-131 in Renal Anemia Patients With Chronic Kidney Disease (CKD) Phase 3
Completed NCT02930850 - Spot-Check Noninvasive Hemoglobin (SpHb) Clinical Validation N/A
Completed NCT02888171 - Impact of Ferric Citrate vs Ferrous Sulfate on Iron Parameters and Hemoglobin in Individuals With CKD and Iron Deficiency N/A
Completed NCT03822884 - Pharmacokinetic/Pharmacodynamic Study of 3 Subcutaneous Single Dose Epoetin Alfa Formulations in Healthy Volunteers Phase 1
Completed NCT02912494 - A Phase III Study of JR-131 in Renal Anemia Patients With Chronic Kidney Disease (CKD) Phase 3
Completed NCT02384122 - Efficacy of Octreotide on Blood and Iron Requirements in Patients With Anemia Due to Angiodysplasias Phase 3
Completed NCT02603250 - Evaluation of Hemoglobin Measurement Tools for Child Anemia Screening in Rwanda N/A
Completed NCT02176759 - Iron Absorption From Rice Fortified With Ferric Pyrophosphate N/A
Completed NCT01922479 - Pilot Study of Ferric Carboxymaltose to Treat Iron Deficiency in Asians With Heart Failure Phase 4
Withdrawn NCT01934842 - A Study to Compare Analyte Levels in Blood Collected Using an Investigational Collection Device With a Commercial Predicate N/A
Completed NCT02310113 - Transfusion and Skeletal Muscle Tissue Oxygenation N/A
Completed NCT01693029 - Study to Compare Safety and Efficacy of HX575 Epoetin Alfa and US-licensed Epoetin Alfa Phase 3
Completed NCT01458028 - Age and Gender Effects on the Pharmacokinetics of BAY85-3934 Phase 1
Completed NCT01432717 - Study of ACE-536 in Healthy Postmenopausal Women Phase 1