Narrow Band Imaging (NBI) with high-definition (HDTV) visualization has been implemented into GI endoscopy with the purpose to better highlight endoluminal pathological structures by improving their contrast. Previous studies from referral centers could not show significant differences in terms of colonoscopic adenoma detection rate, but either very high adenoma rates or some numerical differences suggested that some benefit may exist which may become evident with average adenoma rates and/or large case numbers.

In a prospective randomized trial performed exclusively in a multicenter private practice setting involving 6 examiners with substantial life-time experience (>10.000 colonoscopies) 1200 patients will undergo HDTV screening colonoscopy with either NBI or conventional imaging technique on instrument withdrawal. Primary outcome measure is the adenoma detection rate (ADR; i.e. number of adenomas per patient).


Clinical Trial Description

in 5 private practices with 6 examiners, consecutive asymptomatic persons willing to undergo screening colonoscopy will be asked to participate in this randomized study.

After introduction of the colonoscope into the cecum, patients will be randomized into withdrawal with either the NBI mode or conventional imaging by using wide-angle colonoscopes with HDTV imaging (Olympus Corp., Hamburg, Germany) in both groups. Randomization lists will be used for group allocation in each individual practice. In the NBI group, switching back to conventional imaging, and the number of occasions for switching back and the reasons for it are documented in this group.

Patients bowel preparation consists mostly of polyethylene glycol lavage with 4-5 liters until clear rectal fluid is evacuated. All examiners shall take special care to wash and clean the entire large bowel during instrument introduction and withdrawal, in order to provide optimal imaging conditions.

The following parameters are documented:

- Age and sex of the patient

- Type and dosage of sedation

- Examination time, both for instrument introduction and withdrawal

- Polyp characteristics: size (measured by open forceps or snare), shape (pedunculated/elevated, sessile/flat, and location

- Polyp histology after removal using snare polypectomy or forceps removal (for polyps < 3 mm), or biopsy if there are contraindications

- Other lesions found such as cancers, diverticula, inflammatory lesions etc. The main outcome parameter is the adenoma detection rate (number of polyps/number of patients examined) in the two groups.

Secondary outcome measures include analysis of the total number of polyps, flat/sessile adenomas, small adenomas (< 1 cm), hyperplastic polyps with size determination and right-sided versus left-sided polyp location in both groups. ;


Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT00633620
Study type Interventional
Source Charite University, Berlin, Germany
Contact
Status Completed
Phase N/A
Start date March 2007
Completion date October 2007

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05551052 - CRC Detection Reliable Assessment With Blood
Recruiting NCT02545699 - Prospective Trial to Compare ADR of G-EYE™ Colonoscopy With Standard Colonoscopy N/A
Completed NCT01802008 - Comparison of Adenoma Detection Miss Rates at Colonoscopy Associated With Different Withdrawal Times N/A
Recruiting NCT01211132 - Cap Assisted Colonoscopy for the Detection of Colon Polyps N/A
Completed NCT04287335 - Multitarget Stool FIT-DNA Study for Colorectal Cancer Early Screening in China
Not yet recruiting NCT06398418 - R-5780-01 In Combination With PD-1 Checkpoint Inhibitors (Checkpoint Protein on Immune Cells Called T Cells) in Patients With Solid Tumors Phase 1
Recruiting NCT05362344 - Colorectal Cancer Screening in Cystic Fibrosis
Completed NCT03268200 - The Effect of Segmental Re-examination of Colon for Adenoma Detection in Colonoscopy N/A
Recruiting NCT04591145 - Multi-center Validation of a Deep Learning Based Bowel Preparation Evaluation System
Completed NCT02978664 - The Impact of Distraction on Adenoma Detection Rate N/A
Completed NCT00018551 - Chemoprevention With Folic Acid Phase 2
Recruiting NCT05594576 - Comparison of the ENDOCUFF VISION® Endoscopy Cap Coupled With GI GENIUS™ Artificial Intelligence Compared to Each Device Alone in Improving Colonic Adenoma Detection Rate During Colonoscopy N/A
Not yet recruiting NCT04135716 - A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy N/A
Recruiting NCT02552017 - Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities N/A
Recruiting NCT02288962 - Dopamine Agonist Treatment of Non-functioning Pituitary Adenomas Phase 3
Completed NCT02066064 - G-Eye Advanced Colonoscopy For Increased Polyp Detection Rate-randomized Tandem Study With Different Endoscopist N/A
Completed NCT01749722 - Safety and Efficacy of the NaviAid™ G-Eye System During Colonoscopy N/A
Withdrawn NCT01546259 - Water Method in Low-body Mass Index (BMI) Female Patients With Unsedated Colonoscopy N/A
Completed NCT01485133 - Water Method Colonoscopy in Patients With Prior Surgery N/A
Withdrawn NCT01546220 - Water Method in Elder Patients With Unsedated Colonoscopy N/A