Abdominal Aortic Aneurysm Clinical Trial
Official title:
Prospective, Open-label, Multicenter, Non-randomized Clinical Study to Determine the Safety and Efficacy of SETA LATECBA Stent Graft for Endovascular Repair Therapy (EVAR) in Subjects With Abdominal Aortic Aneurysm (AAA).
This is a Prospective, Open-label, Multicenter, and Non-randomized Clinical Study. The main purpose of this study is to establish the efficacy and safety of a medical device system, SETA LATECBA Stent Graft, intended for the treatment of EVAR of pararenal AAA (patients with complex anatomy, not eligible for other surgical procedure).Other objective is to evaluate the technical performance of the device SETA LATECBA Stent Graft.
Status | Recruiting |
Enrollment | 42 |
Est. completion date | March 31, 2022 |
Est. primary completion date | December 31, 2021 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: - Male and female adults older than 18 years old, willing to cooperate with the study. No other demographic restriction. - Initial diagnosis of AAA according to the standard of care criteria following the guidance Clinical Practice Guidelines for Endovascular Abdominal Aortic Aneurysm Repair - Medical history: Complete history of previous, present and concomitant conditions, and current treatments for other conditions Signed informed consent. If the patient cannot consent, the subject's legally acceptable representative should consent Diagnosis of Abdominal Aortic Aneurysm (AAA) according to the following criteria: 1. Diagnosis of an abdominal aortic aneurysm with a diameter = 5.0 cm for males or = 4.5 cm for females. 2. Aneurysm diameter with a growth rate = 0.5 cm/ 6 months 3. The juxtarenal neck length between 1 mm and 10 mm 4. Neck diameter =16 to = 26 mm 5. Suprarenal aorta diameter = infrarenal aorta diameter 6. Proximal neck angulated = 60 degrees relative to the long axis of the aneurysm 7. Immediate suprarenal aorta angulated = 60 degrees relative to the immediate infrarenal neck. 8. Common iliac diameter 8 to 20 mm. 9. Common iliac length 25 mm 10. Common iliac angle 60 degrees 11. Not eligible for other standard EVAR surgical procedure Exclusion Criteria: - General Exclusion Criteria 1. Life expectancy less than 2 years 2. Pregnant or breastfeeding or planning on becoming pregnant within 60 months 3. Included in another investigative drug or device study/studies or planning to do it within the following 24 months Medical Exclusion Criteria 1. Previous treatment of AAA 2. Known allergy to polyester, stainless steel, nitinol and or gold, teflon, nylon, 3. Known anaphylactic reaction to contrast media. 4. Any type coagulopathy untreated. 5. Genetic connective tissue diseases, such as Marfan or Ehlers-Danlos syndromes 6. Planned interventional or surgical procedure within 30 days before or after AAA repair. 7. Renal dysfunction: creatinine level over 1.7 mg/dl 8. Systemic infection or fever over 38°C AAA Anatomy Exclusion Criteria 9. Significant occlusive disease, tortuosity, or calcification. i) Significant thrombus in the fixation sites. j) Fungal aneurysm k) Leaking/ruptured or symptomatic aneurysm. l) Traumatic aneurysm. m) Concurrent aneurysm of the thoracic aorta. n) One or both renal arteries coming from the aneurysmal sac. o) Proximal neck diameter, measured outer wall to outer wall on a sectional image (CTA) > 26 mm in diameter or < 16 mm in diameter p) Proximal neck angle > 60 degrees relative to the long axis of the aneurysm q) Immediate suprarenal aorta angle > 60 degrees relative to the immediate infrarenal neck. r) Immediate suprarenal aorta angle > 60 degrees relative to the immediate infrarenal neck s) Aortic diameter, measured inner wall to inner wall on a sectional image (CTA) < 15 mm at the bifurcation t) Iliac/femoral anatomy that is unsuitable for access. u) Iliac artery diameter, measured outer wall to outer Wall on a sectional image (CTA) > 20 mm or < 8 mm at distal fixation site. v) Iliac artery distal fixation site < 10 mm in length. w) Indispensable inferior mesenteric artery (IMA) |
Country | Name | City | State |
---|---|---|---|
Canada | Centre Hospitalier Universitaire Sherbrooke | Sherbrooke | Montreal |
Lead Sponsor | Collaborator |
---|---|
Latecba S.A. |
Canada,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | EFFICACY: Number of participants with Endoleak Type I (measured by Angio CT Scan) | Type I endoleaks is diagnosed when there is a gap between the stent graft and the vessel wall. Usually is a result of the failure of the stent graft to achieve a circumferential seal of the aneurism. It produces systemic pressurization of the aneurysm sac and increases the risk of sac rupture. | 30 days | |
Primary | SAFETY: mortality | percentage of died subjects | 30-day | |
Secondary | SAFETY: Major Adverse Events | Composite endpoint including Q-wave myocardial infarction, Congestive heart failure, Cardiac ischemia requiring intervention Renal failure requiring dialysis, Bowel obstruction, ischemia or fistula, Stroke, Paralysis, Aneurysm leak and Device related death | 30-day | |
Secondary | Incidence of post-operative complications | Complications of aneurysm repair followed by secondary interventions | 12 months | |
Secondary | Clinical success | Composite endpoint including Successful deployment at intended site, No migration, Aneurysm exclusion, no type III and/or IV endoleak, No graft infection, No graft thrombosis, No aneurysm rupture, No conversion to open repair, | 30-day | |
Secondary | Clinical success | Composite endpoint including No migration, Aneurysm exclusion, no type I, III and/or IV endoleak, No graft thrombosis, No aneurysm rupture. No aneurysm diameter expansion >5 mm, No conversion to open repair | 6 months | |
Secondary | Clinical success | Composite endpoint including No migration, Aneurysm exclusion, no type I, III and/or IV endoleak, No graft thrombosis, No aneurysm rupture. No aneurysm diameter expansion >5 mm, No conversion to open repair | 12 months | |
Secondary | Technical Success of stent-graft implantation and delivery system usage | Composite endpoint including Assessment of system performance (Procedural times, Total blood loss, Deployment and device patency Ease of insertion, Visualization, Delivery system retrieval, Device integrity, Kinks, No type IV endoleak) Ancillary equipment needed, Adjunctive maneuvers (Balloon dilatation of aortic neck Balloon dilatation of iliac arteries, Additional stent or surgical procedure required, Eventual use of proximal cuff, Contrast media volume) | 12 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04227054 -
Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks
|
N/A | |
Active, not recruiting |
NCT03687489 -
Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System
|
N/A | |
Active, not recruiting |
NCT03507413 -
Metformin Therapy in Non-diabetic AAA Patients
|
Phase 2/Phase 3 | |
Not yet recruiting |
NCT05756283 -
The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair
|
N/A | |
Not yet recruiting |
NCT04089241 -
Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair
|
N/A | |
Active, not recruiting |
NCT02604303 -
A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
|
||
Completed |
NCT02229006 -
Sodium Fluoride Imaging of Abdominal Aortic Aneurysms
|
N/A | |
Terminated |
NCT02469376 -
Evaluation of a New Imagingtechnologie for Thrombosis
|
Phase 1 | |
Terminated |
NCT01843335 -
Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair
|
N/A | |
Completed |
NCT02224794 -
LIFE Study: Least Invasive Fast-Track EVAR
|
||
Terminated |
NCT01425242 -
Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension
|
N/A | |
Completed |
NCT01118520 -
AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK)
|
Phase 2 | |
Completed |
NCT00746122 -
Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair
|
N/A | |
Completed |
NCT03952780 -
Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
|
||
Completed |
NCT00583414 -
Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients
|
N/A | |
Recruiting |
NCT05864560 -
Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
|
||
Completed |
NCT01683084 -
Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms
|
Phase 4 | |
Active, not recruiting |
NCT03180996 -
Global Fenestrated Anaconda Clinical sTudy
|
||
Completed |
NCT02493296 -
The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
|
||
Completed |
NCT03320408 -
Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers
|