Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT04089241
Other study ID # 490-19RMB
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date September 2020
Est. completion date April 2023

Study information

Verified date September 2020
Source Rambam Health Care Campus
Contact Erez Klein, MD
Phone 97247772664
Email erezklein@gmail.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Abdominal Aortic Aneurysm (AAA) is a known vascular entity that may be life threatening condition .The most common treatment approach nowadays is the endovascular approach, a procedure known as endovascular aortic repair (EVAR). The most common procedure related complication is the expansion of the aneurysm from a "feeding vessel", usually a lumbar or intercostal artery. Another known complication is an endoleak from the stentgraft.Today, accepted EVAR follow up protocol consists of one multiple multiphasic CT angiography (CTA) scan, one month after the procedure and ultrasound exams there after . Ultrasonography is a useful method for detection and evaluation of AAA, has no ionizing radiation and is useful for the dynamic estimation of the aortic width in patients post EVAR. However, the sensitivity of ultrasonography solely for detection of endoleaks in post EVAR patients is not high.In recent years, the development of "fusion" applications allows the dual modality merge between ultrasound and CT scans that can be used as follow up examinations of known imaging findings on CT .Another application that had been developed for ultrasound machines is the ability to generate a 3 dimensional (3D) reconstruction which allows more precision. In the recent year the usage of intravenous contrast agent for ultrasonography based on microbubbles (BRACO SONOVIEW) has been approved by the Israeli ministry of health. This contrast agent is not nephrotoxic and the risk for allergic reaction is very low statistically similar to Gadolinium.A 3D contrast enhanced ultrasonography "fused" together with CTA may be a helpfull addition , which lacks radiation and odine contrast reactions and nephrotoxicity ,in the follow up in post EVAR patients , by means of identifing endoleaks at an earlier stage than by ultrasound alone. The purpose of our research is to evaluate the combined modality (fusion of CTA with CEUS) mentioned above in identifing early endoleaks in post EVAR patients and thus enabilng early intervention when needed


Description:

Abdominal Aortic Aneurysm (AAA) is a known vascular entity that may be life threatening and requires treatment once it's diameter exceeds 5.5 cm or in any diameter in symptomatic patients.

Known risk factors for developing Abdominal Aortic Aneurysm (AAA) include tabacco consumption, Sex (male predominance), age (above 65 with a history of smoking or age above 75 without a history of smoking ), hypertension, diabetes mellitus and hyperchlesterolemia1 The most common treatment approach nowadays is the endovascular approach, a procedure known as endovascular aortic repair (EVAR). The most common procedure related complication is the expansion of the aneurysm from a "feeding vessel", usually a lumbar or intercostal artery. Another known complication is an endoleak from the stentgraft, through its proximal or distal part/.

Today, accepted EVAR follow up protocol consists of a multiphasic CT angiography (CTA) scan .The initial scan is performed without contrast, the second scan is performed in the arterial phase and a third scan is performed in the late (portal) phase. CTA is performed at one month after the procedure and ultrasound exams there after.

Ultrasonography is a useful method for detection and evaluation of AAA and is recommended as an annual screening tool for patients above 65 with smoking history or above 75 without smoking history. Duplex Ultrasonography has no ionizing radiation and is useful for the dynamic estimation of the aortic width in patients post EVAR. However, the sensitivity of ultrasonography solely for detection of endoleaks in post EVAR patients is not high, mostly due to known inborn limitations of ultrasound including decreased penetration in obese patients , and suboptimal demonstration of retroperitoneal structures due to gas in the intestine.

In recent years, the development of "fusion" applications allow the dual modality merge between ultrasound and CT scans. The dual modality allows the direct comparison of imaging findings in real time. Fusion imaging is used as follow up examinations of known imaging findings on CT that cannot be optimally demonstrated on ultrasonography. Once these findings are followed up by ultrasonography, an substantial amount of radiation can be reduced.

Another application that had been developed for ultrasound machines nowadays is the ability to generate a 3 dimensional (3D) reconstruction which allows more precision. 2D and 3D ultrasound imaging as a follow up imaging modality after endovascular aortic repair (EVAR) procedures has been described in medical literature3,4.

In the recent year the usage of intravenous contrast agent for ultrasonography based on microbubbles (BRACO SONOVIEW) has been approved by the Israeli ministry of health. This intravenous contrast agent has been in usage for several years in Europe and have been recently approved officially in our country in the examination of liver, breast, vascular cerebral lesions and peripheral blood vessels. This contrast agent is not nephrotoxic and the risk for allergic reaction is very low statistically similar to Gadolinium. The contrast agent is purely intravascular and does not leak to the the interstitium, therefore can be used efficiently for the detection of endoleaks.

This contrast agent has yet to be approved by ministry of health for the application in aorta imaging. Nevertheless, the European federation of societies for ultrasound in medicine and biology (EFSUMB) has specific guidelines for the usage of this contrast agent for the detection of stent grafts endoleaks (5) .

A 3D contrast enhanced ultrasonography "fused" together with CTA may be an appropriate substitute for the standard CTA follow up in post EVAR patients and thus substantially reduce radiation doses as well as iodine contrast reactions and nephrotoxicity .

The purpose of our research is to evaluate the combined modality (fusion of CTA with CEUS) mentioned above in identifing early endoleaks in post EVAR patients and thus enabilng early intervention when needed


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 20
Est. completion date April 2023
Est. primary completion date April 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria

- Patients with a diagnosis of AAA

- AAA treated endovascularly

- Patients send from the outpatient clinic to a follow up imaging study

Exclusion Criteria

• AAA treated surgically and not endovascularly

Study Design


Intervention

Other:
Contrast 3D Ultrasound
an ultrasound examination which will include a 3D reconstruction and thereafter CEUS will be performed using SONOVIEW contrast agent

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Rambam Health Care Campus

Outcome

Type Measure Description Time frame Safety issue
Primary Accuracy of the detection of endoleak by contrast 3D Ultrasound fused with CTA in the follow up of EVAR patients For each patient that will undergo the fused modality , the results of the presence or absence of endoleak and the type of the endoleak, if detected, will be compared to the gold standard CTA . two years
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04227054 - Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks N/A
Active, not recruiting NCT03687489 - Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System N/A
Active, not recruiting NCT03507413 - Metformin Therapy in Non-diabetic AAA Patients Phase 2/Phase 3
Not yet recruiting NCT05756283 - The PREHAAAB Trial: Multimodal Prehabilitation for Patients Awaiting Open Abdominal Aortic Aneurysm Repair N/A
Active, not recruiting NCT02604303 - A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
Terminated NCT01843335 - Contrast-enhanced Ultrasound in Follow-up After Endovascular Aneurysm Repair N/A
Completed NCT02224794 - LIFE Study: Least Invasive Fast-Track EVAR
Completed NCT02229006 - Sodium Fluoride Imaging of Abdominal Aortic Aneurysms N/A
Terminated NCT02469376 - Evaluation of a New Imagingtechnologie for Thrombosis Phase 1
Terminated NCT01425242 - Study on Anti-inflammatory Effect of Anti-hypertensive Treatment in Patients With Small AAA's and Mild Hypertension N/A
Completed NCT01118520 - AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) Phase 2
Completed NCT00746122 - Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair N/A
Completed NCT03952780 - Korean Registry of Percutaneous EVAR With INCRAFT Stent Graft for the Treatment of Abdominalaortic Aneurysm (K-INCRAFT)
Completed NCT00583414 - Endovascular Exclusion of Abdominal Aortic Aneurysms in High Risk Patients N/A
Recruiting NCT05864560 - Ankura™ AAA, Cuff and AUI Stent Graft System Post-Market Clinical Follow-Up
Completed NCT01683084 - Study of the Effectiveness of Telmisartan in Slowing the Progression of Abdominal Aortic Aneurysms Phase 4
Active, not recruiting NCT03180996 - Global Fenestrated Anaconda Clinical sTudy
Completed NCT02493296 - The Effect of Surgery on Central Aortic Pressure & haEmodynamics Study
Completed NCT03320408 - Predicting Aneurysm Growth and Rupture With Longitudinal Biomarkers
Completed NCT03837704 - Comparison of Abdominal Aortic Aneurysm Growth in Adult Smoking Patients Who Either Switch to IQOS, Continue Smoking, or Quit Smoking. N/A