Citation(s)
- Abuzakuk T, Senthil Kumar V, Shenava Y, Bulstrode C, Skinner JA, Cannon SR, Briggs TW
Autotransfusion drains in total knee replacement. Are they alternatives to homologous transfusion? Int Orthop. 2007 Apr;31(2):235-9. doi: 10.1007/s00264-006-0159-y. Epub 2006 Jun 8.
- Barsoum WK, Klika AK, Murray TG, Higuera C, Lee HH, Krebs VE
Prospective randomized evaluation of the need for blood transfusion during primary total hip arthroplasty with use of a bipolar sealer. J Bone Joint Surg Am. 2011 Mar 16;93(6):513-8. doi: 10.2106/JBJS.J.00036.
- Clement RC, Kamath AF, Derman PB, Garino JP, Lee GC
Bipolar sealing in revision total hip arthroplasty for infection: efficacy and cost analysis. J Arthroplasty. 2012 Aug;27(7):1376-81. doi: 10.1016/j.arth.2011.11.016. Epub 2012 Jan 21.
- Diedo N, Moore G, et al
Effectiveness of the bipolar sealer in reducing blood loss in total knee arthroplasty. International Journal of Orthopaedic and Trauma Nursing (2013) 17, 29-37
- Dunne JR, Malone D, Tracy JK, Gannon C, Napolitano LM
Perioperative anemia: an independent risk factor for infection, mortality, and resource utilization in surgery. J Surg Res. 2002 Feb;102(2):237-44. doi: 10.1006/jsre.2001.6330.
- Eipe NP, Ponniah M
Perioperative blood loss assessment-how accurate? Indian J Anaesth. 2006;50(1):35-38
- Esler CN, Blakeway C, Fiddian NJ
The use of a closed-suction drain in total knee arthroplasty. A prospective, randomised study. J Bone Joint Surg Br. 2003 Mar;85(2):215-7. doi: 10.1302/0301-620x.85b2.13357.
- Gibon E, Courpied JP, Hamadouche M
Total joint replacement and blood loss: what is the best equation? Int Orthop. 2013 Apr;37(4):735-9. doi: 10.1007/s00264-013-1801-0. Epub 2013 Feb 6.
- Johansson T, Engquist M, Pettersson LG, Lisander B
Blood loss after total hip replacement: a prospective randomized study between wound compression and drainage. J Arthroplasty. 2005 Dec;20(8):967-71. doi: 10.1016/j.arth.2005.02.004.
- Kamath AF, Austin DC, Derman PB, Clement RC, Garino JP, Lee GC
Saline-coupled bipolar sealing in simultaneous bilateral total knee arthroplasty. Clin Orthop Surg. 2014 Sep;6(3):298-304. doi: 10.4055/cios.2014.6.3.298. Epub 2014 Aug 5.
- Konig G, Hamlin BR, Waters JH
Topical tranexamic acid reduces blood loss and transfusion rates in total hip and total knee arthroplasty. J Arthroplasty. 2013 Oct;28(9):1473-6. doi: 10.1016/j.arth.2013.06.011. Epub 2013 Jul 23.
- Lyons ST, Morrison K, Bernasek TL
Sensory neuropathy associated with cauterization using bipolar radio frequency device in primary TKA. Paper presented at: American Academy of Orthopaedic Surgeons Annual Meeting; March 9-13, 2010; New Orleans, LA
- Marulanda GA, Krebs VE, Bierbaum BE, Goldberg VM, Ries M, Ulrich SD, Seyler TM, Mont MA
Hemostasis using a bipolar sealer in primary unilateral total knee arthroplasty. Am J Orthop (Belle Mead NJ). 2009 Dec;38(12):E179-83.
- Marulanda GA, Ulrich SD, Seyler TM, Delanois RE, Mont MA
Reductions in blood loss with a bipolar sealer in total hip arthroplasty. Expert Rev Med Devices. 2008 Mar;5(2):125-31. doi: 10.1586/17434440.5.2.125.
- Morris MJ, Barrett M, Lombardi AV Jr, Tucker TL, Berend KR
Randomized blinded study comparing a bipolar sealer and standard electrocautery in reducing transfusion requirements in anterior supine intermuscular total hip arthroplasty. J Arthroplasty. 2013 Oct;28(9):1614-7. doi: 10.1016/j.arth.2013.01.032. Epub 2013 Mar 16.
- Morris MJ, Berend KR, Lombardi AV Jr
Hemostasis in anterior supine intermuscular total hip arthroplasty: pilot study comparing standard electrocautery and a bipolar sealer. Surg Technol Int. 2010 Oct;20:352-6.
- Pfeiffer M, Brautigam H, Draws D, Sigg A
A new bipolar blood sealing system embedded in perioperative strategies vs. a conventional regimen for total knee arthroplasty: results of a matched-pair study. Ger Med Sci. 2005 Dec 13;3:Doc10.
- Plymale MF, Capogna BM, Lovy AJ, Adler ML, Hirsh DM, Kim SJ
Unipolar vs bipolar hemostasis in total knee arthroplasty: a prospective randomized trial. J Arthroplasty. 2012 Jun;27(6):1133-7.e1. doi: 10.1016/j.arth.2011.09.016. Epub 2011 Nov 4.
- Rodgers A, Walker N, Schug S, McKee A, Kehlet H, van Zundert A, Sage D, Futter M, Saville G, Clark T, MacMahon S
Reduction of postoperative mortality and morbidity with epidural or spinal anaesthesia: results from overview of randomised trials. BMJ. 2000 Dec 16;321(7275):1493. doi: 10.1136/bmj.321.7275.1493.
- Rosenberg AG
Reducing blood loss in total joint surgery with a saline-coupled bipolar sealing technology. J Arthroplasty. 2007 Jun;22(4 Suppl 1):82-5. doi: 10.1016/j.arth.2007.02.018.
- Saltzman BM, Oni JK
A Review of Bipolar Sealer Use in Modern Total Joint Arthroplasty. Ann Orthop Rheumatol. 2014 2(2): 1015
- Spahn DR, Goodnough LT
Alternatives to blood transfusion. Lancet. 2013 May 25;381(9880):1855-65. doi: 10.1016/S0140-6736(13)60808-9.
- Strahovnik A, Fokter SK, Kotnik M
Comparison of drainage techniques on prolonged serous drainage after total hip arthroplasty. J Arthroplasty. 2010 Feb;25(2):244-8. doi: 10.1016/j.arth.2008.08.014. Epub 2008 Dec 4.
- Suarez JC, Slotkin EM, Szubski CR, Barsoum WK, Patel PD
Prospective, Randomized Trial to Evaluate Efficacy of a Bipolar Sealer in Direct Anterior Approach Total Hip Arthroplasty. J Arthroplasty. 2015 Nov;30(11):1953-8. doi: 10.1016/j.arth.2015.05.023. Epub 2015 May 19.
- Tobias JD
Strategies for minimizing blood loss in orthopedic surgery. Semin Hematol. 2004 Jan;41(1 Suppl 1):145-56. doi: 10.1053/j.seminhematol.2003.11.025.
- Weeden SH, Schmidt RH, Isabell G
Haemostatic efficacy of a bipolar sealing device in minimally invasive total knee arthroplasty. J Bone Joint Surg Br Proceedings 2009; 91-B:45.
- Yang Y, Zhang LC, Xu F, Li J, Lv YM
Bipolar sealer not superior to standard electrocautery in primary total hip arthroplasty: a meta-analysis. J Orthop Surg Res. 2014 Oct 10;9:92. doi: 10.1186/s13018-014-0092-5.
- Zeh A, Messer J, Davis J, Vasarhelyi A, Wohlrab D
The Aquamantys system--an alternative to reduce blood loss in primary total hip arthroplasty? J Arthroplasty. 2010 Oct;25(7):1072-7. doi: 10.1016/j.arth.2009.10.008. Epub 2010 Jan 22.
A Prospective, Randomized, Single-blinded, Non-inferiority Study to Evaluate the Safety and Efficacy of the Saline-coupled Bipolar Sealer Compared to the Unipolar Electrocautery in Primary Unilateral Total Knee Arthroplasty
Details for clinical trial NCT03952546