Osteoarthritis, Hip — Measured vs Navigated Techniques in Total Hip Arthroplasty
Citation(s)
Agarwal S, Eckhard L, Walter WL, Peng A, Hatton A, Donnelly B, de Steiger R The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation: A Study of 6,912 Navigated THA Procedures from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Joint Surg Am. 2021 Oct 20;103(20):1900-1905. doi: 10.2106/JBJS.20.00950.
Amuwa C, Dorr LD The combined anteversion technique for acetabular component anteversion. J Arthroplasty. 2008 Oct;23(7):1068-70. doi: 10.1016/j.arth.2008.04.025. Epub 2008 Jun 4.
Blumenfeld TJ Pearls: Clinical Application of Ranawat's Sign. Clin Orthop Relat Res. 2017 Jul;475(7):1789-1790. doi: 10.1007/s11999-017-5376-8. Epub 2017 May 11.
Bonnin MP, Archbold PH, Basiglini L, Fessy MH, Beverland DE Do we medialise the hip centre of rotation in total hip arthroplasty? Influence of acetabular offset and surgical technique. Hip Int. 2012 Jul-Aug;22(4):371-8. doi: 10.5301/HIP.2012.9350.
Bosker BH, Verheyen CC, Horstmann WG, Tulp NJ Poor accuracy of freehand cup positioning during total hip arthroplasty. Arch Orthop Trauma Surg. 2007 Jul;127(5):375-9. Epub 2007 Feb 13.
Christ A, Ponzio D, Pitta M, Carroll K, Muir JM, Sculco PK Minimal Increase in Total Hip Arthroplasty Surgical Procedural Time with the Use of a Novel Surgical Navigation Tool. Open Orthop J. 2018 Sep 28;12:389-395. doi: 10.2174/1874325001812010389. eCollection 2018.
Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J. 2005;25:1-9.
Dorr LD, Malik A, Dastane M, Wan Z Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009 Jan;467(1):119-27. doi: 10.1007/s11999-008-0598-4. Epub 2008 Nov 1.
Dorr LD, Wan Z, Malik A, Zhu J, Dastane M, Deshmane P A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am. 2009 Nov;91(11):2598-604. doi: 10.2106/JBJS.H.01225.
Fang CJ, Shaker JM, Ward DM, Jawa A, Mattingly DA, Smith EL Financial Burden of Revision Hip and Knee Arthroplasty at an Orthopedic Specialty Hospital: Higher Costs and Unequal Reimbursements. J Arthroplasty. 2021 Aug;36(8):2680-2684. doi: 10.1016/j.arth.2021.03.044. Epub 2021 Mar 23.
Grammatopoulos G, Thomas GE, Pandit H, Beard DJ, Gill HS, Murray DW The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J. 2015 Feb;97-B(2):164-72. doi: 10.1302/0301-620X.97B2.34294.
Gupta R, Pathak P, Singh R, Majumdar KP Double-Stitch Technique: A Simple and Effective Method to Minimize Limb Length Discrepancy after Total Hip Arthroplasty. Indian J Orthop. 2019 Jan-Feb;53(1):169-173. doi: 10.4103/ortho.IJOrtho_188_18.
Hu X, Zheng N, Chen Y, Dai K, Dimitriou D, Li H, Tsai TY Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty. Front Bioeng Biotechnol. 2021 Mar 30;9:645019. doi: 10.3389/fbioe.2021.645019. eCollection 2021.
Jacob I, Benson J, Shanaghan K, Gonzalez Della Valle A Acetabular positioning is more consistent with the use of a novel miniature computer-assisted device. Int Orthop. 2020 Mar;44(3):429-435. doi: 10.1007/s00264-020-04484-2. Epub 2020 Jan 22.
Kievit AJ, Dobbe JGG, Mallee WH, Blankevoort L, Streekstra GJ, Schafroth MU Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens. Hip Int. 2021 Jan;31(1):58-65. doi: 10.1177/1120700019874822. Epub 2019 Sep 11.
Lee YK, Kim JW, Kim TY, Ha YC, Koo KH Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach. Orthop Traumatol Surg Res. 2018 May;104(3):341-346. doi: 10.1016/j.otsr.2017.11.023. Epub 2018 Feb 16.
Meermans G, Goetheer-Smits I, Lim RF, Van Doorn WJ, Kats J The difference between the radiographic and the operative angle of inclination of the acetabular component in total hip arthroplasty: use of a digital protractor and the circumference of the hip to improve orientation. Bone Joint J. 2015 May;97-B(5):603-10. doi: 10.1302/0301-620X.97B5.34781.
Meermans G, Van Doorn WJ, Koenraadt K, Kats J The use of the transverse acetabular ligament for determining the orientation of the components in total hip replacement: a randomised controlled trial. Bone Joint J. 2014 Mar;96-B(3):312-8. doi: 10.1302/0301-620X.96B3.32989.
Mitsutake R, Tanino H, Nishida Y, Higa M, Ito H A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty. BMC Musculoskelet Disord. 2020 Feb 19;21(1):113. doi: 10.1186/s12891-020-3142-7.
Murray DW The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993 Mar;75(2):228-32.
Ogawa T, Takao M, Hamada H, Sakai T, Sugano N Soft tissue tension is four times lower in the unstable primary total hip arthroplasty. Int Orthop. 2018 Sep;42(9):2059-2065. doi: 10.1007/s00264-018-3908-9. Epub 2018 Mar 27.
Paprosky WG, Muir JM Intellijoint HIP(®): a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty. Med Devices (Auckl). 2016 Nov 18;9:401-408. eCollection 2016.
Parvizi J, Benson JR, Muir JM A new mini-navigation tool allows accurate component placement during anterior total hip arthroplasty. Med Devices (Auckl). 2018 Mar 22;11:95-104. doi: 10.2147/MDER.S151835. eCollection 2018.
Pongkunakorn A, Chatmaitri S, Diewwattanawiwat K Use of smartphone to improve acetabular component positioning in total hip athroplasty: A comparative clinical study. J Orthop Surg (Hong Kong). 2019 Jan-Apr;27(1):2309499019825578. doi: 10.1177/2309499019825578. Erratum in: J Orthop Surg (Hong Kong). 2019 Jan-Apr;27(1):2309499019834501.
Snijders T, van Gaalen SM, de Gast A Precision and accuracy of imageless navigation versus freehand implantation of total hip arthroplasty: A systematic review and meta-analysis. Int J Med Robot. 2017 Dec;13(4). doi: 10.1002/rcs.1843. Epub 2017 May 29. Review.
Steppacher SD, Kowal JH, Murphy SB Improving cup positioning using a mechanical navigation instrument. Clin Orthop Relat Res. 2011 Feb;469(2):423-8. doi: 10.1007/s11999-010-1553-8.
Accuracy in aChieving Optimum reconstrUction: Measured- vs. Navigation- Techniques in Hip Arthroplasty
Interventional studies are often prospective and are specifically tailored to evaluate direct impacts of treatment or preventive measures on disease.
Observational studies are often retrospective and are used to assess potential causation in exposure-outcome relationships and therefore influence preventive methods.
Expanded access is a means by which manufacturers make investigational new drugs available, under certain circumstances, to treat a patient(s) with a serious disease or condition who cannot participate in a controlled clinical trial.
Clinical trials are conducted in a series of steps, called phases - each phase is designed to answer a separate research question.
Phase 1: Researchers test a new drug or treatment in a small group of people for the first time to evaluate its safety, determine a safe dosage range, and identify side effects.
Phase 2: The drug or treatment is given to a larger group of people to see if it is effective and to further evaluate its safety.
Phase 3: The drug or treatment is given to large groups of people to confirm its effectiveness, monitor side effects, compare it to commonly used treatments, and collect information that will allow the drug or treatment to be used safely.
Phase 4: Studies are done after the drug or treatment has been marketed to gather information on the drug's effect in various populations and any side effects associated with long-term use.