Clinical Trials Logo

Citation(s)

  •   Hernandez-Alfaro F, Guijarro-Martinez R
    New protocol for three-dimensional surgical planning and CAD/CAM splint generation in orthognathic surgery: an in vitro and in vivo study. Int J Oral Maxillofac Surg. 2013 Dec;42(12):1547-56. doi: 10.1016/j.ijom.2013.03.025. Epub 2013 Jun 13.
  •   Heufelder M, Wilde F, Pietzka S, Mascha F, Winter K, Schramm A, Rana M
    Clinical accuracy of waferless maxillary positioning using customized surgical guides and patient specific osteosynthesis in bimaxillary orthognathic surgery. J Craniomaxillofac Surg. 2017 Sep;45(9):1578-1585. doi: 10.1016/j.jcms.2017.06.027. Epub 2017 Jul 8.
  •   Jabar N, Robinson W, Goto TK, Khambay BS
    The validity of using surface meshes for evaluation of three-dimensional maxillary and mandibular surgical changes. Int J Oral Maxillofac Surg. 2015 Jul;44(7):914-20. doi: 10.1016/j.ijom.2015.02.005. Epub 2015 Mar 6.
  •   Kraeima J, Schepers RH, Spijkervet FKL, Maal TJJ, Baan F, Witjes MJH, Jansma J
    Splintless surgery using patient-specific osteosynthesis in Le Fort I osteotomies: a randomized controlled multi-centre trial. Int J Oral Maxillofac Surg. 2020 Apr;49(4):454-460. doi: 10.1016/j.ijom.2019.08.005. Epub 2019 Sep 8.
  •   Mazzoni S, Bianchi A, Schiariti G, Badiali G, Marchetti C
    Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning. J Oral Maxillofac Surg. 2015 Apr;73(4):701-7. doi: 10.1016/j.joms.2014.10.028. Epub 2014 Nov 29.
  •   Ong TK, Banks RJ, Hildreth AJ
    Surgical accuracy in Le Fort I maxillary osteotomies. Br J Oral Maxillofac Surg. 2001 Apr;39(2):96-102. doi: 10.1054/bjom.2000.0577.
  •   Pascal E, Majoufre C, Bondaz M, Courtemanche A, Berger M, Bouletreau P
    Current status of surgical planning and transfer methods in orthognathic surgery. J Stomatol Oral Maxillofac Surg. 2018 Jun;119(3):245-248. doi: 10.1016/j.jormas.2018.02.001. Epub 2018 Feb 22.
  •   Pietzka S, Mascha F, Winter K, Kammerer PW, Sakkas A, Schramm A, Wilde F
    Clinical Accuracy of 3D-Planned Maxillary Positioning Using CAD/CAM-Generated Splints in Combination With Temporary Mandibular Fixation in Bimaxillary Orthognathic Surgery. Craniomaxillofac Trauma Reconstr. 2020 Dec;13(4):290-299. doi: 10.1177/1943387520949348. Epub 2020 Aug 17.

Reverse Engineering Utilizing the 3D Photogrammetry Technique Versus Commercial Scanners for Accurate Repositioning of the Maxilla After Le-fort I Osteotomy for Correction of the Dentofacial Deformity (Randomized Controlled Clinical Trial).

Details for clinical trial NCT05755022