Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04287036
Other study ID # CR-6396
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date February 12, 2020
Est. completion date February 26, 2020

Study information

Verified date April 2021
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a single visit, single site, brand-masked, non-dispensing, 2×2 bilateral crossover study. Each subject will be bilaterally fitted with one of the two test articles in each of the study periods.


Recruitment information / eligibility

Status Completed
Enrollment 28
Est. completion date February 26, 2020
Est. primary completion date February 26, 2020
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 39 Years
Eligibility Inclusion Criteria: - Potential subjects must satisfy all of the following criteria to be enrolled in the study: 1. The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form 2. Appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. Subjects between 18 and 39 (inclusive) years of age at the time of screening 4. Be a current soft contact lens wearer in both eyes with a minimum of 6 hours/day and 5 days/week over the last month by self-report. 5. The subject must be willing to be photographed and/or video-taped. 6. The subject's vertex corrected spherical equivalent distance refraction must be in the range of -1.00 D to -5.00 D (inclusive) in each eye 7. The subject's refractive cylinder must be less than or equal to 0.75 D (inclusive) in each eye 8. Have spherical best corrected visual acuity of 20/25 or better in each eye. Exclusion Criteria: - Potential subjects who meet any of the following criteria will be excluded from participating in the study: 1. Currently pregnant or lactating 2. Any systemic disease (eg, Sjögren's Syndrome), allergies, infectious disease (eg, hepatitis, tuberculosis), contagious immunosuppressive diseases (eg, HIV), autoimmune disease (eg rheumatoid arthritis), or other diseases, by self-report, which are known to interfere with contact lens wear and/or participation in the study (at the investigators discretion). 3. Use of systemic medications (eg, chronic steroid use) that are known to interfere with contact lens wear (at the investigators discretion). 4. Any previous or planned (during the study) ocular surgery (eg, radial keratotomy, PRK, LASIK, etc.). 5. Participation in any contact lens or lens care product clinical trial within seven (7) days prior to study enrollment 6. Employee or family members of clinical site (eg, Investigator, Coordinator, Technician). 7. Any ocular allergies, infections or other ocular abnormalities that are known to interfere with contact lens wear and/or participation in the study. This may include, but not be limited to entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, or corneal distortion (at the investigators discretion). 8. Clinically significant (Grade 3 or 4 on FDA scale) tarsal abnormalities, bulbar injection, corneal edema, corneal vascularization, corneal staining, or any other abnormalities of the cornea which would contraindicate contact lens wear.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
JJVC Investigational Contact Lens
TEST
1-DAY ACUVUE® DEFINE® Radiant Sweet™
CONTROL

Locations

Country Name City State
United States VRC-East Jacksonville Florida

Sponsors (1)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Distance Binocular Visual Acuity (logMAR) Visual acuity on logMAR (Logarithm of Minimal Angle of Resolution) scale was evaluated at distance (4 meters) under high luminance high contrast, high luminance low contrast and low luminance high contrast with distance goggles using ETDRS (Early Treatment Diabetic Retinopathy Study) charts. Letter-by-letter results calculated the visual performance score for each chart read. logMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR value of 0.0 is equivalent to 20/20 Snellen vision. 20- Minutes Post-Lens Fitting
Primary Near BinocularVisual Acuity (logMAR) Visual acuity on logMAR (Logarithm of Minimal Angle of Resolution) scale was evaluated at near (40 cm) under High luminance low contrast and low luminance high contrast with distance goggles using ETDRS (Early Treatment Diabetic Retinopathy Study) charts. Letter-by-letter results calculated the visual performance score for each chart read. logMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR value of 0.0 is equivalent to 20/20 Snellen vision. 20- Minutes Post-Lens Fitting
Primary Quantitative Visual Acuity Quantitative Visual Acuity (qVA) was measured at distance (4 meter) under low room illumination (4 lux), low luminance, high contrast conditions in the right eye only and in both eyes using AST Sentio vision Testing System. During testing 25 triplets of test letters were displayed on a large stationary monitor (118 CM), the operator recorded the patient's responses using the remote (Android Tablet). After a testing session had been completed the software calculated the VA threshold. VA threshold was defined as the logMAR stimulus size at which the expected probability of correct letter identification is 66%. when both eyes are measured. The average median VA threshold was reported for each lens. Lower values indicate better vision. 20- Minutes Post-Lens Fitting
Primary Area Under Contrast Sensitivity Function Curve Area under the log Curve was measured at 1.5, 3, 6, 12 and 18 cycles per degree (cpd) in the right eye only and in both eyes using AST Sentio vision Testing System. During testing 25 triplets of test letters were displayed on a large stationary monitor (118 CM), the operator recorded the patient's responses using the remote (Android Tablet). After a testing session had been completed the software calculated the Area under the log contrast sensitivity function from 1.5 cpd to 18 cpd. The average area under the log curve was reported for each lens. Higher values indicate better vision. Number of eyes is 50 when both eyes are measured. 20- Minutes Post-Lens Fitting
See also
  Status Clinical Trial Phase
Completed NCT06019806 - Effects of Forward Head Posture Correction on Visual Acuity in Low Level Visually Impaired University Students N/A
Completed NCT04567186 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Hyperopic Population N/A
Completed NCT02568254 - Evaluation of Three Daily Disposable Contact Lenses N/A
Completed NCT01951703 - Senofilcon A Investigational Manufacturing Process N/A
Terminated NCT00637468 - EAGLE - Multicenter Study of the European Assessment Group for Lysis in the Eye Phase 3
Recruiting NCT04632901 - A New Parameter for the Assessment of Distance Visual Capacity: the Critical Visual Acuity (CVA)
Active, not recruiting NCT03747601 - Temporal Interference Brain Stimulation N/A
Completed NCT06131476 - Clinical Investigation of Visual Acuity in Contact Lens Wearers After Instillation of a Lipid- Based Lubricating Eye Drop Phase 1
Recruiting NCT05414565 - Post-Market Study of Alcon Intraocular Lenses
Completed NCT05056870 - Clinical Evaluation of Spherical Soft Contact Lenses, Toric Soft Contact Lenses and Spectacles in Low Astigmats N/A
Completed NCT04615507 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Myopic Population; Part 2 N/A
Completed NCT05099380 - Validation of Senofilcon A With New UV / HEV Filter N/A
Completed NCT03713281 - Evaluation of a Toric Multifocal Contact Lens Manufactured in Etafilcon Material in a Low ADD Hyperopic Population
Completed NCT05582304 - Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study N/A
Completed NCT03742271 - Evaluation of Senofilcon A With New UV-blocker on a Neophyte Population N/A
Completed NCT04995055 - Evaluation of Multifocal Contact Lens Designs With and Without an HEV Blocker on Visual Function N/A
Completed NCT05554640 - Clinical Performance of Two Daily Disposable Silicone Hydrogel Contact Lenses N/A
Completed NCT01926704 - MTF Image Modifications N/A
Completed NCT04649606 - Dynamic Characterisation of Meibomian Gland Structure
Completed NCT05101252 - Comparison of a Daily Disposable Multifocal Contact Lens to a Marketed Product N/A