Visual Acuity Clinical Trial
Official title:
Ocular Characteristics in Contact Lens and Spectacle Wear
NCT number | NCT03913377 |
Other study ID # | CR-6332 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | April 9, 2019 |
Est. completion date | June 14, 2019 |
Verified date | January 2021 |
Source | Johnson & Johnson Vision Care, Inc. |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
This clinical study will investigate the difference in ocular characteristics between contact lens wear and spectacle wear among habitual contact lens wearers, using a 2-treatment by 2-period cross-over design. There will be a 1-week washout between the two study periods to eliminate any potential carryover effect.
Status | Completed |
Enrollment | 78 |
Est. completion date | June 14, 2019 |
Est. primary completion date | June 14, 2019 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years to 42 Years |
Eligibility | Inclusion Criteria: - Potential subjects must satisfy all of the following criteria to be enrolled in the study: 1. The subject will have completed the pre-screening Classification questionnaire. 2. Subject must have a working cell phone capable of sending and receiving text messages. 3. The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 4. Appear able and willing to adhere to the instructions set forth in this clinical protocol. 5. Between 18 and 42 (inclusive) years of age at the time of screening 6. Be a current soft contact lens wearer in both eyes with a minimum of 5 days/week wear time over the last 1 month by self-report OR be a full-time spectacle wearer (7 days/ week) without contact lens wear over the last 6 months. 7. Subjects must be willing to adhere to spectacle-only refractive correction for approximately 1 week. 8. Subjects must possess a functional / usable pair of spectacles with which they can achieve 20/20 Snellen visual acuity or better at distance and near, and bring them to the visit 9. The subject's vertex corrected spherical distance refraction must be in the range (+/-0.25 D) of -2.00 D to -6.00 D (inclusive) in each eye. 10. The subject's vertex corrected refractive cylinder must be equal or less than -0.75 diopters in each eye. 11. Contact lens wearers must have spherical best corrected visual acuity of 20/25 or better in each eye. 12. Snellen visual acuity at distance and near must be within 1 line between subject's own spectacle and the manifest refraction, distance and near, OD & OS. Exclusion Criteria: - Potential subjects who meet any of the following criteria will be excluded from participating in the study: 1. Currently pregnant or lactating, by self-report 2. Any ocular or systemic allergies, disease or use of medication which may interfere with contact lens wear and/or participation in the study (at the discretion of the investigator). 3. Any active ocular abnormalities/conditions that may interfere with contact lens wear and/or participation in the study (at the discretion of the investigator). 4. Any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear 5. Habitual contact lens wear modality as extended wear (=1 night per month of extended wear). 6. Habitual contact lens is rigid gas permeable, toric, monovision or multi-focal 7. Habitual spectacle contains an add power, photochromic or tint. 8. Any previous, or planned (during the course of the study) ocular surgery (e.g., radial keratotomy, PRK, LASIK, etc.) 9. Participation in any contact lens or lens care product clinical trial within 2 weeks prior to study enrollment. 10. Employee or employee's immediate family member of clinical site (e.g., Investigator, Coordinator, Technician) 11. Current habitual use of Restasis, Xiidra, ocular steroids, or any medication (RX or OTC) that may interfere with contact lens wear and/or participation in the study (at the discretion of the investigator) 12. Any ocular allergies, infections or other ocular abnormalities that are known to interfere with contact lens wear and/or participation in the study. This may include, but not be limited to entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, or corneal distortion. 13. Any Grade 3 or greater biomicroscopy findings (this includes, corneal edema, corneal staining, corneal vascularization, conjunctival injection, tarsal abnormalities, bulbar injection) on the FDA classification scale (CTP-2018). 14. Accommodative/binocular dysfunction, determined by study procedures. |
Country | Name | City | State |
---|---|---|---|
United States | VRC-East | Jacksonville | Florida |
United States | Sabal Eye Care | Longwood | Florida |
United States | Manhattan Vision Associates | New York | New York |
Lead Sponsor | Collaborator |
---|---|
Johnson & Johnson Vision Care, Inc. |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Non-Invasive Break Up Time (NIBUT) or Non-Invasive Keratograph Break Up Time (NIKBUT) | NIBUT/NIKBUT was measured as the time interval in seconds after the final blink to the first appearance of distortion in the reflected rings; or to the time that the participant has to blink due to discomfort. NIBUT is measured by a topographer (e.g. Medmont) via observation by the investigator and a stopwatch. NIKBUTis measured by the Oculus Keratograph and reported by the instrument. Different instrumentation was used depending on site availability. Combined measurements of pre-lens data collected for the interventional arm are reported. Only the interventional arm was reported since the primary analysis was conducted among habitual contact lens users. The average NIKBUT was reported for each treatment. Higher values indicate better performance | 1-Week Follow-up | |
Secondary | Total Scores of Meibomian Gland Expressibility (MGE) | Meibomian gland expressiblity was assessed in three regions of the lower eyelid: temporal, central, and nasal. Each region is expressed and the overall grade of the region is evaluated using a four-grade scale: 0 = No Secretion, 1 = Inspissated, 2 = Colored/Cloudy Liquid, and 3 = Clear Liquid Oil. The total score was calculated as the sum of all grades across the three regions and ranged from 0 (no secretion) to 9, with higher scores indicating more MGE. Total scores were converted into a binary variable for the analysis purpose where Y=1 if the total score is greater than 6 and 0 otherwise. The percentage of participants with MGE total score greater than 6 was estimated. Only the interventional arm was reported since the secondary analysis was conducted among habitual contact lens users. | 1-Week Follow-up | |
Secondary | Conjunctival Staining | Conjunctival staining was graded and recorded by quadrant (Superior, Inferior, Nasal, and Temporal) using the following grading scale: Grade 0 = None, Grade 1 = Trace, Grade 2 = Mild, Grade 3 = Moderate, and Grade 4 = Severe. Average grade was calculated based on grades of the four quadrants. Only the interventional arm was reported since the secondary analysis was conducted among habitual contact lens users. | 1-Week Follow-up | |
Secondary | Number of Eyes With Clinically Significant (Grade 3 or 4 of Overall Classification) Lid Wiper Epitheliopathy | Horizontal lid margin staining and sagittal lid margin staining are graded for each eyelid (upper and lower) separately. The horizontal and sagittal grades are then averaged for each eyelid to obtain the upper lid average grade and lower lid average grade. The final grade is the average of the upper and lower lid average grades. Participants can be classified according to their final grades for each eye. The classification is defined as follows: "None" for final grades of 0, "Mild" for final grades between 0.25 and 1.00, "Moderate" for final grades between 1.25 and 2.00, and "Severe" for final graded between 2.25 and 3.00. Only the interventional arm was reported since the secondary analysis was planned to be conducted among habitual contact lens users only. | 1-Week Follow-up | |
Secondary | Meibomian Gland Expressibility (MGE) Grades | Meibomian gland expressiblity was assessed in three regions of the lower eyelid: temporal, central, and nasal. Each region is expressed and the overall grade of the region is evaluated using a four-grade scale: 0 = No Secretion, 1 = Inspissated, 2 = Colored/Cloudy Liquid, and 3 = Clear Liquid Oil. Only the interventional arm was reported since the secondary analysis was conducted among habitual contact lens users. | 1-Week Follow-up |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT06019806 -
Effects of Forward Head Posture Correction on Visual Acuity in Low Level Visually Impaired University Students
|
N/A | |
Completed |
NCT04567186 -
Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Hyperopic Population
|
N/A | |
Completed |
NCT02568254 -
Evaluation of Three Daily Disposable Contact Lenses
|
N/A | |
Completed |
NCT01951703 -
Senofilcon A Investigational Manufacturing Process
|
N/A | |
Terminated |
NCT00637468 -
EAGLE - Multicenter Study of the European Assessment Group for Lysis in the Eye
|
Phase 3 | |
Recruiting |
NCT04632901 -
A New Parameter for the Assessment of Distance Visual Capacity: the Critical Visual Acuity (CVA)
|
||
Active, not recruiting |
NCT03747601 -
Temporal Interference Brain Stimulation
|
N/A | |
Completed |
NCT06131476 -
Clinical Investigation of Visual Acuity in Contact Lens Wearers After Instillation of a Lipid- Based Lubricating Eye Drop
|
Phase 1 | |
Recruiting |
NCT05414565 -
Post-Market Study of Alcon Intraocular Lenses
|
||
Completed |
NCT05056870 -
Clinical Evaluation of Spherical Soft Contact Lenses, Toric Soft Contact Lenses and Spectacles in Low Astigmats
|
N/A | |
Completed |
NCT04615507 -
Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Myopic Population; Part 2
|
N/A | |
Completed |
NCT05099380 -
Validation of Senofilcon A With New UV / HEV Filter
|
N/A | |
Completed |
NCT03713281 -
Evaluation of a Toric Multifocal Contact Lens Manufactured in Etafilcon Material in a Low ADD Hyperopic Population
|
||
Completed |
NCT05582304 -
Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study
|
N/A | |
Completed |
NCT03742271 -
Evaluation of Senofilcon A With New UV-blocker on a Neophyte Population
|
N/A | |
Completed |
NCT04995055 -
Evaluation of Multifocal Contact Lens Designs With and Without an HEV Blocker on Visual Function
|
N/A | |
Completed |
NCT05554640 -
Clinical Performance of Two Daily Disposable Silicone Hydrogel Contact Lenses
|
N/A | |
Completed |
NCT01926704 -
MTF Image Modifications
|
N/A | |
Completed |
NCT04649606 -
Dynamic Characterisation of Meibomian Gland Structure
|
||
Completed |
NCT05101252 -
Comparison of a Daily Disposable Multifocal Contact Lens to a Marketed Product
|
N/A |