Clinical Trials Logo

Clinical Trial Summary

The WHO, states that age related cataracts account for 51 percent of worldwide blindness and affect about 20 million people. Surgery with intraocular lens (IOL) implantation is the first line treatment for cataracts, thus there is an on going effort to improve IOL design and performance.

It is planned to compare three different IOL designs in a psychophysical test setting. Most IOL testing is done in 2D scenarios such as Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity or contrast sensitivity testing. The use of 3D scenario would allow testing a more real-life situation.

As various downsides of different IOL designs have been reported, testing of IOLs before surgical implantation is a promising approach to maximise patient satisfaction. Known deficiencies include amongst others reduced contrast sensitivity or light intensity.

To test three different IOL designs, it is planned to have 2D healthy young subjects look through a stable, table mounted spectacle frame, in which the different IOLs can be inserted. This allows for subjective testing of IOL's in a 2D and 3D scenario.


Clinical Trial Description

n/a


Study Design

Intervention Model: Single Group Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Basic Science


Related Conditions & MeSH terms


NCT number NCT02409641
Study type Interventional
Source Medical University of Vienna
Contact
Status Completed
Phase N/A
Start date February 2015
Completion date April 2015

See also
  Status Clinical Trial Phase
Completed NCT06019806 - Effects of Forward Head Posture Correction on Visual Acuity in Low Level Visually Impaired University Students N/A
Completed NCT04567186 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Hyperopic Population N/A
Completed NCT02568254 - Evaluation of Three Daily Disposable Contact Lenses N/A
Completed NCT01951703 - Senofilcon A Investigational Manufacturing Process N/A
Terminated NCT00637468 - EAGLE - Multicenter Study of the European Assessment Group for Lysis in the Eye Phase 3
Recruiting NCT04632901 - A New Parameter for the Assessment of Distance Visual Capacity: the Critical Visual Acuity (CVA)
Active, not recruiting NCT03747601 - Temporal Interference Brain Stimulation N/A
Completed NCT06131476 - Clinical Investigation of Visual Acuity in Contact Lens Wearers After Instillation of a Lipid- Based Lubricating Eye Drop Phase 1
Recruiting NCT05414565 - Post-Market Study of Alcon Intraocular Lenses
Completed NCT05056870 - Clinical Evaluation of Spherical Soft Contact Lenses, Toric Soft Contact Lenses and Spectacles in Low Astigmats N/A
Completed NCT04615507 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Myopic Population; Part 2 N/A
Completed NCT05099380 - Validation of Senofilcon A With New UV / HEV Filter N/A
Completed NCT03713281 - Evaluation of a Toric Multifocal Contact Lens Manufactured in Etafilcon Material in a Low ADD Hyperopic Population
Completed NCT05582304 - Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study N/A
Completed NCT03742271 - Evaluation of Senofilcon A With New UV-blocker on a Neophyte Population N/A
Completed NCT04995055 - Evaluation of Multifocal Contact Lens Designs With and Without an HEV Blocker on Visual Function N/A
Completed NCT05554640 - Clinical Performance of Two Daily Disposable Silicone Hydrogel Contact Lenses N/A
Completed NCT01926704 - MTF Image Modifications N/A
Completed NCT04649606 - Dynamic Characterisation of Meibomian Gland Structure
Completed NCT05101252 - Comparison of a Daily Disposable Multifocal Contact Lens to a Marketed Product N/A