Clinical Trials Logo

Clinical Trial Summary

STEP ICD is a premarket, exploratory, early feasibility, interventional study designed to evaluate the preliminary safety and performance of the Investigational Devices. The study is intended to inform the final device design which will be further evaluated in traditional feasibility and /or pivotal clinical investigations. The primary safety objective is to characterize safety of the EV-ICD Lead through 3 months post-implant. The primary performance objective is to characterize sensing and conversion of induced VF with the EV-ICD Lead up to 3 months post-implant.


Clinical Trial Description

The primary safety endpoint is incidence of Adverse Device Effects (ADEs). The primary performance endpoint is induced VF conversion success up to 3 months post-implant. Secondary endpoints include defibrillation metrics (i.e., lowest Conversion Energy (J), ability to automatically sense and detect ventricular arrhythmias, detection time and time-to-therapy) and pacing metrics (ventricular capture threshold (V), pacing impedance (ohms), R-wave amplitude (mV), and extracardiac pacing sensation level). Up to 30 eligible Subjects undergoing a pectoral transvenous ICD procedure (de novo or replacement) will receive an EV-ICD Lead connected to a commercially available ICD in a left mid-axillary or left pectoral pocket. The EV-ICD System will be tested in the intended implant location to determine the lowest defibrillation energy. Subjects will remain in the hospital overnight (at a minimum), prior to discharge. Except during testing, the EV-ICD System will remain programmed to monitor only (therapy OFF) to detect and store ventricular arrhythmias over the follow-up period. A concomitantly implanted transvenous ICD (TV-ICD) system will provide any necessary ICD therapy. Non-therapy EV-ICD programming parameters will match the TV-ICD to the extent possible to facilitate recording of matched stored electrograms. Follow-up visits are planned at pre-discharge, 2 weeks, 1 month, 2 months, and 3 months. VF conversion testing will occur prior to lead removal in order to test subchronic defibrillation effectiveness with a submaximal energy shock in standard and/or reverse polarity. At the Lead Removal Follow Up, the EV-ICD System will be explanted and the TV-ICD System left in place. A final follow-up will occur one month after EV-ICD Lead explant to assess any post-explant adverse events prior to study exit. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05791032
Study type Interventional
Source AtaCor Medical, Inc.
Contact
Status Completed
Phase N/A
Start date September 5, 2023
Completion date March 19, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT03453645 - Modification of Rhythmic Risk Assessment by Ventricular Tachycardia Ablation
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Completed NCT04011631 - Evaluation of the iD-SystemTM, One-Handed Disposable Internal Defibrillation System. N/A
Recruiting NCT03536052 - Ablation at Virtual-hEart pRedicted Targets for VT N/A
Not yet recruiting NCT06063811 - Ventricular Tachycardia Ablation in LVAD Patients
Enrolling by invitation NCT02962076 - Study of Cardiac PET/CT Imaging to Guide Ablation Treatment of Ventricular Tachycardia Early Phase 1
Not yet recruiting NCT02784912 - Biomarkers in Risk Stratification of Sustainted Ventricular Tachycardia or Electrical Storm After Ablation N/A
Completed NCT01791543 - Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia N/A
Terminated NCT02891863 - Low Energy Therapy to Convert Ventricular Tachycardias Phase 0
Terminated NCT01546207 - Stepwise Approach To sUbstrate Modification for Ventricular Tachycardia N/A
Completed NCT01294267 - Percutaneous Hemodynamic Support With Impella 2.5 During Scar-related Ventricular Tachycardia Ablation N/A
Terminated NCT00383799 - Iv Amiodarone Versus Iv Procainamide to Treat Haemodynamically Well Tolerated Ventricular Tachycardia Phase 4
Completed NCT04884100 - enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening N/A
Completed NCT04642963 - Stereotactic Management of Arrhythmia - Radiosurgery in Treatment of Ventricular Tachycardia N/A
Recruiting NCT05377216 - Characterization of Cardiac Electrophysiological Effects of Autonomic Neuromodulation Early Phase 1
Not yet recruiting NCT04990089 - VIVO European Observational Registry
Completed NCT04065893 - Impact of Catheter Ablation of Ventricular Arrhythmias on Suboptimal Biventricular Pacing in Cardiac Resynchronization Therapy
Recruiting NCT03631303 - Post-Extrasystolic Potentiation as a Predictor of Ventricular Arrhythmias
Recruiting NCT03611465 - Creation of a Pace-mapping Atlas on Healthy and Pathological Hearts N/A
Suspended NCT05478213 - Ventricular Tachycardia Mechanisms N/A