Ventricular Fibrillation Clinical Trial
Official title:
Automated External Defibrillator (AED) Use in Out-of-Hospital Cardiac Arrest: A New Algorithm Named "One Shock Per Minute"
The aim of the trial is to evaluate a new AED algorithm that proposes a new timeline between
the time devoted to administer a defibrillation shock, and the time devoted to chest
compressions.
The researchers propose to decrease the periods of interruption of cardiopulmonary
resuscitation (CPR), while keeping the principle of early defibrillation.
Early use of semi-automated external defibrillators (AED) by Emergency Care teams in
out-of-hospital cardiac arrest (OHCA), has been correlated with a significant gain in
sequelae-free survival. The AED is programmed with an algorithm based recommended
guidelines.
We will test a new algorithm that takes into account recent findings in pathophysiology.
Patients presenting with cardiovascular and pulmonary arrest treated by the BSPP Emergency
Care who meet inclusion criterion are proposed for inclusion in the trial.
The aim of the trial is to evaluate a new AED algorithm that proposes a new timeline between
the time devoted to administer a defibrillation shock, and the time devoted to chest
compressions.
The new algorithm is entitled "one shock per minute". Use of this algorithm should validate
several hypotheses:
- the importance of administering cardiac massage and artificial ventilation (CPR) prior
to initiation of electrical shock treatment.
- the importance of continuing CPR immediately following electrical shock treatment
- the importance of reducing time between CPR procedures to a minimum
- the fact that three successive electrical shocks are of no therapeutic benefit.
We want to compare the control algorithm with the new one titled "one shock per minute", for
shocked patients.
The sample size of this trial was calculated to provide a power of 85% and a type 1 error
rate of alpha = 0.0294 for detecting an 11% increase in the rate of hospital admission, from
its historical rate of 34% to a new rate of 45%. One interim analysis was planned with the
stopping boundary alpha = 0.0294. This required inclusion of 430 patients in each group.
The primary endpoint is defined as "the admission of the patient alive at the hospital".
The secondary endpoints are defined as following :
- Detection of Palpable Carotid Pulse (ROSC) within the first 8 minutes after the connection
of the AED The other secondary endpoint is survival to one year.
Concerning patients that do not receive shocks
They represent a priori 82% of the patients. The absolute number is a priori 3940, that is
to say, 1970 in both two groups.
They will be used for an advanced observational descriptive study, to establish hypothesis
for future studies.The same primary and secondary endpoints will be evaluated for them.
Among these patients not shocked, the algorithm foresees 60 seconds of CPR for the Control
Group, and 90 seconds for the Trial Group. This setting relies on the hypothesis that
increasing the time dedicated to chest compressions will increase the probability of return
of a palpable pulse (ROSC), even for patients who do not fibrillate.
Statistical analysis will be completed by "Hôpital d'Instruction des Armées BEGIN -
Epidemiology department"
We propose a comparison using the Chi square test for qualitative variables, Student's t
test for quantitative variables, completion of a logistics model to analyze prognostic
factors, as well as the proportional hazards model for survival analysis. Tests will be
bilateral (significant p = 0,029 if we consider one intermediate analysis).
Overall analysis strategy will be defined and completed by the Epidemiology department of
Hôpital d'Instruction des Armées BEGIN
;
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Completed |
NCT05791032 -
Sub Chronic Evaluation for ATP With an Extravascular Placed ICD Lead (STEP ICD) Study
|
N/A | |
Completed |
NCT04011631 -
Evaluation of the iD-SystemTM, One-Handed Disposable Internal Defibrillation System.
|
N/A | |
Active, not recruiting |
NCT03700125 -
Pre-hospital ECMO in Advanced Resuscitation in Patients With Refractory Cardiac Arrest. ( SUB30 )
|
N/A | |
Not yet recruiting |
NCT05325385 -
Ventricular Fibrillation Following Out-of-hospital Cardiac Arrest
|
||
Completed |
NCT00241800 -
Medications and the Risk of Sudden Cardiac Death
|
N/A | |
Completed |
NCT00119847 -
Electrophysiological Effects of Late PCI After MI
|
N/A | |
Completed |
NCT00004560 -
Public Access Defibrillation (PAD) Community Trial
|
Phase 3 | |
Completed |
NCT00000531 -
Antiarrhythmics Versus Implantable Defibrillators (AVID)
|
Phase 3 | |
Completed |
NCT00000502 -
Evaluation of SC-V Versus Conventional CPR
|
Phase 3 | |
Completed |
NCT00000492 -
Beta-Blocker Heart Attack Trial (BHAT)
|
Phase 3 | |
Completed |
NCT04080986 -
DOuble SEquential External Defibrillation for Refractory VF
|
N/A | |
Completed |
NCT01789554 -
The Use of Mobile Phones in Out of Hospital Cardiac Arrest to Increase Bystander CPR
|
N/A | |
Completed |
NCT01940081 -
The Leiden Nonischemic Cardiomyopathy Study
|
||
Completed |
NCT01089634 -
Left Ventricular Capture Management Study
|
||
Completed |
NCT00382928 -
Automatic External Defibrillation Monitoring in Cardiac Arrest
|
Phase 1 | |
Completed |
NCT01161589 -
First Arrhythmia Collection of Transvenous and Simultaneous Subcutaneous Implantable Defibrillator Data
|
N/A | |
Terminated |
NCT00776087 -
European Health Economic Trial on Home Monitoring in ICD and CRT-D Patients (EuroEco)
|
N/A | |
Recruiting |
NCT04576130 -
A Danish ICD-study in Patients With Coronary Artery Disease Resuscitated From Ventricular Fibrillation
|
N/A | |
Withdrawn |
NCT05236920 -
Utility and Procedural Feasibility of REBOA Operationalized for Non-Trauma Application (UP-FRONT)
|
N/A |