Ultrasound Imaging Clinical Trial
Official title:
Assessment of Artificial Intelligence-based Anatomy Identification Software (Nerveblox) Designed for Ultrasound-guided Peripheral Nerve and Plane Block Scanning Procedures
The goal of this observational study is to assess the accuracy of Artificial Intelligence (AI) software to assist ultrasound scanning prior to peripheral nerve blocks. 40 healthy volunteers are going to be accepted to this study in which ultrasound scanning will be performed for four different block types. The main questions it aims to answer are: - Can Nerveblox, the artificial intelligence software highlight and find the key anatomical landmarks on the provided nerve or plane block correctly? - Can the user obtain a correct view of provided nerve or plane block, when the AI software scan success reaches 100%? Participants will be evaluated under four nerve block regions to identify their key anatomical landmarks using ultrasound-guided artificial intelligence software. Three residents with different levels of Ultrasound-guided Regional Anesthesia(UGRA) experience but eligible to perform UGRA techniques will collect the ultrasound images when the artificial intelligence software scan success fed by ultrasound reached 100%. After collecting US images, each pair of US images(highlighted and raw ) will be evaluated by 2 experts for the accuracy of AI assistance, independently and blindly.
Ultrasound-guided Regional Anesthesia (UGRA) is currently an effective method for the anesthesiologist. In this single-centered study, we aim to assess the accuracy of artificial intelligence effectiveness. All scans will be performed on an FDA-cleared general-purpose ultrasound device (GE Logiq, Wisconsin, USA) and software setup will be provided by the sponsor also having the software (Nerveblox, Smart Alfa Teknoloji San. Ve Tic. A.S., Ankara, Turkey). The methodology of the study is that: - Three independent residents, in the 2nd, 3rd, and 4th years of education in the field of anesthesiology and also eligible to perform UGRA, will be recruited for using the artificial intelligence software (Nerveblox v1.0). - 40 (20 male and 20 female) volunteers will be recruited for the study and the volunteer's demographic information (body mass index, gender, age) will be considered and recorded. - The order of volunteers will be randomized between participants. - Considered peripheral nerve and plane blocks are: 1. Interscalene brachial plexus 2. Supraclavicular brachial plexus 3. Infraclavicular brachial plexus 4. Transversus abdominis plane - Each trainee will reach 100% "scan success" on the Nerveblox to record the raw and highlighted images. - Each trainee will scan only 1 time. On the data analysis: - Evaluation of the accuracy of artificial intelligence software will be completed independently by 2 experts in the field of regional anesthesia using the grading scale (0: mislocated, 1: very poor, 2: poor, 3: good, 4: very good, 5: excellent). - Experts will be asked the evaluate the accuracy of Nerveblox highlighting performance when it reached 100%. - Demographic data averages will be presented on the result of the study. - Data will be analyzed by using SPSS 25.0 software at a 95% confidence level. For the measurements, the mean, standard deviation (SD), minimum, maximum, and median statistics will be provided. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05642234 -
Comparison of Skin - Epidural and Intervertebral Distances in Sitting and Rider Position
|
||
Recruiting |
NCT05872906 -
Using Ultrasound and Acupuncture to Explore the De-qi Location and Reaction of Specific Acupoints
|
N/A | |
Recruiting |
NCT06068647 -
Ultrasound and Respiratory Physiological Signals in Lung Diseases
|
N/A | |
Completed |
NCT06219876 -
Comparison of the Efficacy of High Intensity Laser Therapy and Low Level Laser Therapy in the Carpal Tunnel Syndrome
|
N/A | |
Enrolling by invitation |
NCT05900440 -
Artificial Intelligence for Learning Point-of-Care Ultrasound
|
N/A | |
Completed |
NCT06211946 -
Abdominal Aorta Palpation With Point of Care Ultrasound Imaging Measurements
|
||
Completed |
NCT04511143 -
The Correlation Between Ultrasonography Based Muscle Architecture Parameters and Voluntary Isometric Muscle Strength
|
||
Completed |
NCT04316988 -
Ultrasonography Versus Capnography in Detecting Endotracheal Tube Placement During Intubation in a Tertiary Hospital.
|
||
Active, not recruiting |
NCT04527510 -
Remote Breast Cancer Screening Study
|
||
Recruiting |
NCT05649826 -
Automated Ultrasound Cardiac Guidance Tool
|
||
Completed |
NCT03647618 -
Anatomy Guidance for Regional Anaesthesia
|
||
Completed |
NCT05455346 -
Eccentric Training Effects on Hamstrings Structure, Strength, and Sprint Performance
|
N/A | |
Not yet recruiting |
NCT04652466 -
Ultrasound Imaging to Validate I-gel Placement in pediatrıc Patients
|
||
Enrolling by invitation |
NCT04671992 -
Out Of-plane Technique Against In-plane for Caudal Block
|
N/A | |
Completed |
NCT04822116 -
Continuation of Goal Directed Haemodynamic Optimization in the PACU
|
N/A | |
Recruiting |
NCT03532165 -
Use of Bedside Ultrasound in Emergency Department Patients With Concern for Pulmonary Embolism to Reduce CT Imaging
|
N/A |