Total Hip Arthroplasty Clinical Trial
Official title:
Investigation of Systemic Metal Ion Concentration Following a Ceramic-on-metal Total Hip Arthroplasty
This is a pilot study to compare systemic concentrations of cobalt and chromium in patients that have previously undergone total hip arthroplasties with ceramic on metal and metal on metal bearing surfaces.
This is a pilot study to compare systemic concentrations of cobalt and chromium in patients
that have previously undergone total hip arthroplasties with ceramic on metal and metal on
metal bearing surfaces. Secondary goals include an assessment of osteolysis on radiographs,
potential long term analysis of implant survivability, and cancer rates in the two patient
populations.
Increased metal ion production has been documented in metal-on-metal arthroplasty
articulations. There are several concerns over metal ion production. First, even though
there is a decreased histiocytic response to metallic debris, a dose dependent cytotoxic
response with Interleukin 6, Prostaglandin E2, and Tumor Necrosis Factor alpha persists and
may cause osteolysis in the long term. Second, increased levels of cobalt, chromium and
nickel has been shown to correlate with increased cancer rates in several animal models, and
the carcinogenic risk in humans has not been fully elucidated as yet. Third,
hypersensitivity reactions to metal ion develop in up to 25% of these patients, and 60% of
patients with poorly functioning hip.
Ceramic on metal avoids many of these problems due to the improved wear characteristics. If
the level of metal ion production is significantly reduced and the implant survivability is
proven in long term studies, this articulation may become the preferred method.
;
Observational Model: Cohort, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Terminated |
NCT02818894 -
Spinal Anesthesia in Total Hip Arthroplasty
|
Phase 4 | |
Completed |
NCT02242201 -
Total Hip Arthroplasty (THA) Lumbar Plexus Verses Periarticular
|
Phase 4 | |
Completed |
NCT02414542 -
Minima Clinical Study
|
||
Completed |
NCT01817010 -
Strength and Function Following Total Hip Arthroplasty
|
N/A | |
Completed |
NCT01443975 -
Clinical Evaluation on the Use of the X-pander Device
|
N/A | |
Recruiting |
NCT05530174 -
Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With a Fracture
|
N/A | |
Recruiting |
NCT05530551 -
Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With OA
|
N/A | |
Recruiting |
NCT05054192 -
Reliability and Validity of Modified Four Square Step Test
|
||
Recruiting |
NCT06141928 -
Comparison of Three Different Surgical Approaches on the Functional Outcome After Total Hip Arthroplasty
|
N/A | |
Recruiting |
NCT04492462 -
The Impact of Two Different Physical Therapy Programs in the Rehabilitation of Patients Undergoing Anterior Approach Hip Replacement Surgery
|
N/A | |
Withdrawn |
NCT02926651 -
Single Versus Multi-Dose Oral Tranexamic Acid in Patients at High Risk for Blood Transfusion After Total Joint Arthroplasty
|
Phase 4 | |
Completed |
NCT02308813 -
Predictability of the Ability to Perform an Emergency Stop With Disorders of the Hip
|
N/A | |
Recruiting |
NCT02032017 -
Percutaneous Assisted Approach for Total Hip Replacement and it's Effect on Functional Rehabilitation.
|
N/A | |
Recruiting |
NCT01312077 -
The Analgesic Efficacy of Periarticular Infiltration of Local Anaesthetic for Total Hip Replacement
|
Phase 4 | |
Withdrawn |
NCT01380665 -
Prevena™ Incision Management System Over Primarily Closed Hip and Knee Incisions in Patients Immediately Post Total Hip and Knee Arthroplasty
|
Phase 4 | |
Recruiting |
NCT05893563 -
Corail Stability at 5-Years Post-Total Hip Arthroplasty
|
||
Recruiting |
NCT06088069 -
Effect of Virtual Reality on Perioperative Anxiety, Stress and Pain in Total Hip Arthroplasty
|
N/A | |
Active, not recruiting |
NCT03210844 -
The Clinical Outcomes After Direct Anterior Approach and Microposterior Approach for Total Hip Arthroplasty
|
N/A | |
Recruiting |
NCT04801680 -
Mpact 3D Metal Cup PMS
|
||
Terminated |
NCT02006251 -
Real-Time Instrument for Acetabular Shell Positioning
|