Tetralogy of Fallot Clinical Trial
Official title:
Pulmonary Artery Repair With Covered Stents
The Covered Cheatham-Platinum Stent (CCPS) is being study for repair of tears that occur in the pulmonary artery during dilation (enlargement) of a conduit (passageway) connecting the right ventricle of the heart to the pulmonary arteries. Patients undergoing replacement of their pulmonary valve by transcatheter technique Melody Valve) are at risk of developing such tears in the process of preparing the conduit to accept the new valve. In order to implant such a valve, the connection between the right ventricle and the pulmonary arteries often needs to be enlarged. High pressure balloons may be needed and these balloons can sometimes cause tears in or even rupture of the connecting conduit. Such tears can allow blood to flow into the chest and rarely this can lead to a life-threatening emergency. Experience suggests that such tears can be closed by implanting into the conduit a metallic stent with an outer covering, rebuilding the wall and allowing continuation of the valve implant.
Recent clinical reports from multiple pediatric cardiology programs around the world indicate
that the conduit can be repaired using such a stent. In the United States there are no
commercially available, FDA approved, covered stents of the size required. The Covered
Cheatham Platinum Stent (CCPS) manufactured by the NuMED Corporation of Hopkinton, New York
has been used in Europe since 2003 and more recently in Canada. The CCPS device is not yet
approved by the Food & Drug Administration (FDA). However, it has been used at many hospitals
in the U.S. to repair Right Ventricle to pulmonary artery conduits under Emergency and
Compassionate Use circumstances. The NuMED Covered Cheatham-Platinum Stent (CCPS) is
currently being studied for use in other areas of the body. The investigators are now
studying its use in RV-PA conduits. The use of the Covered Cheatham Platinum Stent in this
research study is investigational.
Only patients found to have a conduit tear during a Melody Valve implant procedure will be
eligible for inclusion into the trial. Implant technique is left to the catheterization
physician. Clinical data obtained during the catheterization, before and after the CCPS
implant will be studied in order to understand factors leading up to the tear and to evaluate
how successful the CCPS is in repairing such defects. Melody valve implant patients are
routinely seen for clinical and echocardiographic reevaluation 6 months after implant.
Patients who have received a CCPS during their Melody valve procedure will likewise be seen.
Results from their clinical evaluation will be reviewed to make sure that the presence of a
CCPS does not diminish the effectiveness of the Melody valve. Finally, the catheterization
angiograms and 6 month follow up echocardiograms will be reviewed by an independent expert to
confirm the clinical readings.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02534792 -
Early Revalvulation After Fallot Repair Improves Clinical Outcome
|
N/A | |
Completed |
NCT00536432 -
Early Re-intervention in Infants and Small Children After Correction of Tetralogy of Fallot
|
N/A | |
Not yet recruiting |
NCT05485545 -
Asynchrony in Operated Tetralogy of Fallot
|
N/A | |
Completed |
NCT01941576 -
Effects of rhBNP in Pediatrics After Corrective Repair of Tetralogy Of Fallot
|
N/A | |
Active, not recruiting |
NCT03983512 -
PULSTA Transcatheter Pulmonary Valve Pre-Approval Study
|
N/A | |
Recruiting |
NCT04581668 -
Impact of NAVA Ventilation on Brain Oxygenation and Perfusion in Children With Congenital Heart Disease
|
N/A | |
Completed |
NCT01762124 -
Study of the Native Outflow Tract Transcatheter Pulmonary Valve (TPV)
|
N/A | |
Active, not recruiting |
NCT02161471 -
Haemodynamics and Function of the Atria in Congenital Heart Disease by Cardiovascular Magnetic Resonance
|
||
Not yet recruiting |
NCT05916976 -
Repaired Tetralogy of Fallot: Risc Score From MRI & Clinical Data to Predict the Need for Change of Treatment
|
N/A | |
Recruiting |
NCT04106479 -
NIRS in Congenital Heart Defects - Correlation With Echocardiography
|
||
Completed |
NCT05579964 -
The Role of Dexmedetomidine as Myocardial Protector in Pediatric Cardiac Surgery Total Correction of Tetralogy of Fallot
|
Phase 2/Phase 3 | |
Recruiting |
NCT05236153 -
Electroanatomic Interactions Between Transcatheter Pulmonary Valve Prostheses and Anatomic Isthmuses in Repaired Tetralogy of Fallot
|
N/A | |
Recruiting |
NCT03049995 -
Stress Echo 2020 - The International Stress Echo Study
|
||
Completed |
NCT02586740 -
Retrospective Review of Anesthetic Considerations for Pulmonary Artery Rehabilitation
|
N/A | |
Terminated |
NCT00564993 -
Cardiac Function Under Stress for Early Detection of the Right Ventricular Insufficiency After Repair of Tetralogy of Fallot
|
Phase 3 | |
Recruiting |
NCT05122962 -
Pathophysiologic Mechanism for Arrhythmias and Impaired Aerobic Capacity in Tetralogy of Fallot and Other Congenital Heart Diseases
|
||
Completed |
NCT06097377 -
Lymphatic Magnetic Resonance Imaging Abnormalities in Children With Tetralogy of Fallot: A Case-Control Study
|
||
Completed |
NCT03835494 -
Analysis of RV-Dysfunction in Fallot Patients
|
N/A | |
Not yet recruiting |
NCT03275844 -
Physical Capacity and Activity in Children With Congenital Heart Disease
|
N/A | |
Recruiting |
NCT02590679 -
Multi-center Trial of Percutaneous Pulmonary Valve Implantation With Venus-p
|
Phase 2/Phase 3 |