Temperature Change, Body Clinical Trial
Official title:
Evaluating the Validity of a Rapid Humidity Ramp Protocol for Identifying the Upper Environmental Limits of Thermal Compensation in Humans
The global populace is at growing risk of heat-related illness due to climate change and accompanying increases in the intensity and regularity of extremely hot temperatures. In heat-exposed persons, heat gain from the environment and metabolism initially exceeds the rate of heat dissipation from the skin. Heat is stored in the body, causing core and skin temperatures to rise, which in turn triggers autonomically mediated elevations in cutaneous blood flow and sweating to facilitate heat loss. If conditions are compensable, heat loss increases until it balances total heat gain. At this point, the rate of heat storage falls to zero (i.e., heat balance is achieved) and body temperature stabilizes, albeit at a level elevated from thermoneutral conditions. If, however, the maximal achievable rate of heat dissipation is insufficient to offset heat gain, conditions are uncompensable, and prolonged exposure will cause a continual rise in core temperature that can compromise health if left unchecked. The environmental limits of compensability (i.e., the temperatures/humidities above which heat balance can not be maintained) are therefore an important determinant of survival during prolonged heat exposure. Evaluating this limit and how it can be modified (e.g., by behavior or individual factors like age or sex) is an increasingly important and active field of study. Contemporary evaluations of the environmental limits of compensability utilize "ramping protocols" in which participants are exposed to increasing levels of temperature or humidity (in 5-10 min stages) while core temperature is monitored. It is generally observed that core temperature is relatively stable (or rises slightly) in the early stages of exposure but undergoes an abrupt and rapid increase as heat stress becomes more severe. The conditions (e.g., wet-bulb temperature or wet-bulb globe temperature) at this "inflection point" are taken as the limits of compensability. That is, it is assumed that inflection corresponds to the demarcation point, below which core temperature would remain stable for prolonged periods (theoretically indefinitely if hydration is maintained) but above which heat loss is insufficient to offset heat gain, causing core temperature to rise continuously. Despite the increasing use of these protocols, no study has clearly demonstrated their validity for identifying the environmental limits of compensability. The goal of this project is therefore to assess the validity of ramping protocols for determining the ambient conditions above which thermal compensation is not possible. Enrolled participants will complete four experimental trials in a climate-controlled chamber: one ramping protocol followed by three randomized fixed-condition exposures. In the ramping protocol, participants will rest in 42°C with 28% relative humidity (RH) for 70 min, after which RH will be increased 3% every 10 min until 70% RH is achieved. The core (esophageal) temperature inflection point will be determined. For the fixed-condition exposures, participants will rest in i) 42°C with RH ~5% below their individual inflection point (below-inflection condition), ii) 42°C with RH ~5% above their individual inflection point (above-inflection condition), and iii) 26°C with 45% RH (control condition). Comparing the rate of change in esophageal temperature between each fixed-condition exposure will provide important insight into the validity of ramping protocols for identifying the limits of compensability.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04355013 -
Temperature Monitoring in Cardiac Surgery: Agreement Between Different Clinical Methods
|
||
Recruiting |
NCT04776954 -
Comparison of Normothermia Maintenance Between Resistive Blanket and Forced Air Warming Systems in Renal Transplant Surgery
|
N/A | |
Recruiting |
NCT05692947 -
The Validity of CORE Sensor in Heat Training for Male and Female Endurance Athletes
|
N/A | |
Active, not recruiting |
NCT05344300 -
Temperature Recording in Lungs of Volunteers With and Without Pulmonary Diseases
|
||
Completed |
NCT04057612 -
Correlation Between Core Temperature and Skin Temperature in Pediatrics
|
||
Recruiting |
NCT03896867 -
Heated Humidification System Breathing Circuit for Maintenance of Body Temperature in Pediatric Patients
|
N/A | |
Terminated |
NCT03876808 -
The Effect of Convective Pre-warming on Intra-operative Thermoregulatory Capabilities
|
N/A | |
Recruiting |
NCT04654429 -
Does Higher OT Temperature and IV Ondansetron Reduce Incidence of PSS in Parturients?
|
Phase 4 | |
Terminated |
NCT04489927 -
Validation of the Measurement Accuracy of the Tcore Thermometer
|
||
Completed |
NCT04097249 -
Infrared Thermography for the Diagnosis of Musculoskeletal Pain
|
||
Completed |
NCT06065332 -
Post-Procedural Biotech Cellulose Mask
|
N/A | |
Enrolling by invitation |
NCT04217434 -
Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial
|
N/A | |
Recruiting |
NCT05203809 -
Continuous Temperature Monitoring for tHe Early Recognition of Febrile Neutropenia in Haematological MALignancies
|
||
Completed |
NCT05136482 -
Skin Temperature Changes When Using a Cryocompression Device
|
N/A | |
Completed |
NCT04968080 -
A Study to Validate Comparability of an Infrared Thermographic Camera Versus Oral, Forehead, and Ear Thermometers When Determining Body Temperature in Adult Participants
|
||
Completed |
NCT04608565 -
Remote Biomonitoring (RBM) for Temperature Surveillance of Mothers and Newborns: Pre-clinical and Clinical Evaluation
|
N/A | |
Completed |
NCT05705206 -
Feasibility and Accuracy of Core Temperature Measurements Using the Esophageal Temperature Probe Inserted Through the Gastric Lumen of Supraglottic Airway Device in Pediatrics
|
||
Completed |
NCT04317378 -
Increase in Temperature in Children Undergoing MRI
|
||
Completed |
NCT04252820 -
Prevention of Perioperative Hypothermia in Transurethral Resection Under Spinal Anaesthesia
|
N/A | |
Completed |
NCT03820232 -
Intraoperative Body Core Temperature Monitoring: Oesophageal Probe vs Heated Controlled Servo Sensor
|