Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02536196
Other study ID # REFLECT
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date June 2016
Est. completion date June 2019

Study information

Verified date February 2021
Source Keystone Heart
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The Keystone Heart TriGuard™ HDH is an aortic embolism deflection device intended to reduce the amount of embolic material that may enter the carotid, subclavian, and vertebral arteries during transcatheter heart valve implantation. The objective of the study is to assess the safety and efficacy of the TriGuard™ HDH embolic deflection device in patients undergoing transcatheter aortic valve implantation (TAVI), in comparison with an active control group of patients undergoing unprotected TAVI. Subjects with indications for TAVI and who meet study eligibility criteria will be randomized 2:1 to one of two treatment arms: 1) Intervention: Embolic protection device (TriGuard™) with transcatheter aortic valve implantation or 2) Control: Unprotected transcatheter aortic valve implantation.


Description:

This prospective, single-blind, three arm, randomized, (2 device: 1 control), multicenter safety and efficacy trial is designed to enroll up to 603 total subjects in two consecutive phases: Phase I enrolled 258 subjects (including 54 Roll-Ins) and utilized the TriGuard HDH and Phase II will enroll up to 345 subjects (including 40-50 Roll-Ins) and will utilize the TriGUARD 3 (Figure 3b shows the patient flow/disposition). Phase I In phase I, a total of 204 evaluable subjects and 54 roll-in subjects were enrolled at 26 total investigational sites in the United States, Europe, and Israel, of which 20 sites were in the United States. A minimum of 50% of subjects were planned to be enrolled at US sites, and no single site was permitted to enroll more than 20% of all subjects. Subjects with indications for TAVI and who met study eligibility criteria were randomized 2:1 (stratified by study site) to one of two treatment arms: - Intervention (Phase 1 Cohort) - TAVI with the TriGuard HDH CEPD - Control - standard unprotected TAVI At sites where the investigator did not have prior experience with the TriGuard device (minimum of 2 prior cases), up to 3 roll-in subjects were enrolled. Roll-in subjects were not randomized, but underwent TAVI with the TriGuard HDH device. These cases were proctored by a Sponsor representative. Investigational sites with ≥2 prior TriGuard cases were allowed to enroll 1 roll-in subject at the discretion of the site principal investigator. All subjects were to be followed clinically in-hospital and at 30 and 90 days, and to undergo diffusion-weighted MR imaging 2 to 5 days post-procedure, and neurologic and neuropsychological testing pre-procedure, post-procedure (2-5 days post-procedure), and at 30 and 90 days. The initial randomized cohort expected to enroll up to 285 subjects. Note: Enrollment in Phase I has been halted after enrolling a total of 258 subjects (54 roll-ins and 204 randomized subjects including 63 controls) based on the recommendation of the Data Monitoring Committee following a review of interim 30-day data on 90 subjects at the prespecified interim analysis time point. A next iteration device designed for increased efficacy, ease of use, and improved safety will be tested in Phase II (below). Phase II In Phase II, up to 295 randomized subjects and 40-50 roll-in subjects will be enrolled at up to 25 sites in the United States (inclusive of sites enrolling subjects in Phase I). No single site will be permitted to enroll more than 20% of all randomized subjects in Phase II. Subjects with indications for TAVI and who meet study eligibility criteria will be randomized 2:1 (stratified by study site) to one of two treatment arms: - Intervention - TAVI with the TriGUARD 3 CEPD - Control - standard unprotected TAVI. Randomization will be stratified by implanted valve type (Medtronic vs. Edwards). No single valve type will be implanted in more than approximately 70% of randomized patients (phase II). Roll-in subjects (a minimum of 2 and a maximum of 3 Roll-ins per-site) will not be randomized, but will undergo TAVI with the TriGUARD 3 device. These cases will be proctored by a Sponsor representative. All subjects will be followed clinically in-hospital and at 30 days, undergo diffusion-weighted MR imaging 2 to 5 days post-procedure, and undergo neurologic (NIHSS) testing pre-procedure, post-procedure (2-5 days post-procedure), and at 30 days. A follow-up phone-call to assess the occurrence of death or stroke will be done at 90 days. The initial randomized cohort will consist of up to 225 subjects. After at least 50% of the initial randomized cohort (approximately 112 subjects) have reached the 30 day primary efficacy endpoint evaluation time point, a sample size reestimation will be performed in case the conditional power of the trial (assessed by the independent biostatistician) is >40% but <80%, subject to approval by the Sponsor. If this analysis determines that more than 225 randomized subjects will be required to ensure adequate study power, enrollment may continue until the required number of subjects have been enrolled, or until the total subject limit for the study has been reached (whichever occurs first).


Recruitment information / eligibility

Status Completed
Enrollment 478
Est. completion date June 2019
Est. primary completion date May 2019
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Subjects must meet ALL of the following criteria: General Inclusion Criteria 1. The patient is a male or non-pregnant female =18 years of age 2. The patient meets indications for transcatheter aortic valve implantation (TAVI) 3. The patient is willing to comply with protocol-specified follow-up evaluations 4. The patient, or legally authorized representative, has been informed of the nature of the study, agrees to its provisions and has provided written informed consent, approved by the appropriate Institutional Review Board (IRB) or Ethics Committee (EC). Potential Subjects will be excluded if ANY of the following criteria apply: General Exclusion Criteria 1. Patients undergoing transcatheter aortic valve implantation (TAVI) via the trans-axillary, trans-subclavian, or trans-aortic route 2. Patients undergoing transcatheter aortic valve implantation (TAVI) via the transapical approach due to friable or mobile atherosclerotic plaque in the aortic arch 3. Patients with a previously implanted prosthetic aortic valve (i.e., planned valve-in-valve transcatheter aortic valve implantation (TAVI)) 4. Pregnant or nursing subjects and those who plan pregnancy in the period up to 1 year following index procedure. Female subjects of child-bearing potential must have a negative pregnancy test done within 14 days prior to index procedure per site standard test 5. Patients with known diagnosis of acute myocardial infarction (AMI) within 72 hours preceding the index procedure (according to definition) or AMI >72 hours preceding the index procedure, in whom Creatine Kinase (CK) and CK-MB have not returned to within normal limits at the time of procedure, or patients who are currently experiencing clinical symptoms consistent with new-onset AMI, such as nitrate-unresponsive prolonged chest pain 6. Patients with a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated, patients who will refuse transfusion, or patients with an active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the prior 3 months 7. Patients with known mental or physical illness or known history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation, or is associated with a life expectancy of less than one year 8. Patients with severe allergy or known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel, nitinol, stainless steel alloy, and/or contrast sensitivity that cannot be adequately pre-medicated 9. Patients with a history of a stroke or transient ischemic attack (TIA) within the prior 6 months 10. Patients with renal failure (estimated Glomerular Filtration Rate [eGFR] <30 mL/min, calculated from serum creatinine by the Cockcroft-Gault formula) 11. Patients with hepatic failure (Child-Pugh class C) 12. Patients with hypercoagulable states that cannot be corrected by additional periprocedural heparin 13. Patients presenting with cardiogenic shock at the time of the index procedure 14. Patients with severe peripheral arterial, abdominal aortic, or thoracic aortic disease that precludes delivery sheath vascular access 15. Patients in whom the aortic arch, innominate artery ostium, or proximal innominate artery is heavily calcified, severely atheromatous, or severely tortuous 16. Patients with an innominate artery ostium diameter <10 mm or >25 mm 17. Patients with a transverse aortic diameter >43 18. Patients with anatomic irregularities of the innominate artery that could prevent positioning of the TriGuard upper stabilizer and compromise stability of the device 19. Patients with any other condition that would prevent adherence to the TriGuard HDH Instructions for Use 20. Patients with contraindication to cerebral MRI 21. Patients who have a planned treatment with any other investigational device or procedure during the study period 22. Patients planned to undergo any other cardiac surgical or interventional procedure (e.g., concurrent coronary revascularization) during the TAVI procedure or within 10 days prior to the TAVI procedure. NOTE: Diagnostic cardiac catheterization is permitted within 10 day prior to the TAVI procedure

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Embolic Protection Device
Embolic protection
Procedure:
Transcatheter aortic valve implantation (TAVI)
Transcatheter aortic valve implantation (TAVI)

Locations

Country Name City State
Germany University of Bonn Bonn
Germany Universitats-Herzzentrum Freiburg Freiburg
Germany Hamburg Univeristy Cardiovascular Center Hamburg
Germany Leipzig Heart Institute Leipzig
Italy San Donato Hospital Milano
Italy San Rafeele Hospital Milano
Netherlands UMC Utrecht Utrecht
United States Piedmont Hospital Atlanta Georgia
United States University of Virginia Charlottesville Virginia
United States Morton Plant Hospital Clearwater Florida
United States Cleveland Clinic Cleveland Ohio
United States Baylor Heart and Vascular HospitalBaylor Heart and Vascular Dallas Texas
United States Northwestern University Evanston Illinois
United States Pinnacle Health Harrisburg Pennsylvania
United States Delray Medical Center Hialeah Florida
United States Cardiovascular Institute of the South Houma Louisiana
United States Houston Methodist Hospital Houston Texas
United States University of Texas Houston Texas
United States University of Iowa Iowa City Iowa
United States Cedars-Sinai Medical Center Los Angeles California
United States Morristown Medical Center Morristown New Jersey
United States Yale New Haven Hospital New Haven Connecticut
United States Columbia University Medical Center/NYPH New York New York
United States New York University New York New York
United States University of Pennsylvania Philadelphia Pennsylvania
United States Baylor Research Center Plano Texas
United States St. Francis Hospital Roslyn New York
United States Foundation for Cardiovascular Medicine San Diego California
United States Swedish Medical Center Seattle Washington
United States MedStar Washington Hospital Center Washington District of Columbia

Sponsors (1)

Lead Sponsor Collaborator
Keystone Heart

Countries where clinical trial is conducted

United States,  Germany,  Italy,  Netherlands, 

Outcome

Type Measure Description Time frame Safety issue
Primary Primary Safety Endpoint - Composite Safety Endpoint Based on MACCE Combined safety endpoint at 30 days defined according to VARC-2 ("TAVI early safety") as a composite of:
All-cause mortality - number of patients that expired
All stroke (disabling and non-disabling) - defined by VARC-2 scale
Life-threatening or disabled bleeding - BARC bleeding scale - 5 point scale ranging from no bleeding to fatal
Acute kidney injury - Stage 2 or 3 (including renal replacement therapy)
Coronary artery obstruction requiring intervention
Major vascular complication, and
Valve-related dysfunction requiring repeat procedure (BAV, TAVI, or SAVR) - number of patients in whom a valve related dysfunction occurred It was pre-specified to combine all participants that received the device in the andomized Intervention and Roll-in Arms/Groups for this Outcome Measure.
30 Days
Primary Primary Efficacy Endpoint Hierarchical composite efficacy endpt, determined by pair-wise comparisons among subjects according to hierarchy:
mortality or any stroke [30 days]
death/stroke time to event analysis by days determine win
stroke at same day the comparison moves to next tier
NIHSS worsening [2-5 days post]
Freedom from lesions detected by DW-MRI 2-5 days post
Total volume lesions detected by DW-MRI 2-5 days post Each subj in intervention compared with each subj from control based on hierarchy according to Finkelstein-Schoenfeld method. If Subj A dies or has stroke &Subj B survives free of stroke to 30 days, Subj B wins(score+1) &Subj A loses (score-1). Both die or have stroke, patient with later event wins. Both have death/stroke on same day is equilibrium (score 0). Both are alive & have stroke on same day, comparison moves to next tier. Both stroke-free to 30 days, comparison moves to the next tier. Scores summed to cumulative score for each subj, &outcomes between groups are compared.
Pre-discharge through 30-days
See also
  Status Clinical Trial Phase
Completed NCT03003650 - ACURATE TF™ Transfemoral Aortic Bioprosthesis for Implantation in Patients With Severe Aortic Stenosis:CE-approval Cohort N/A
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Active, not recruiting NCT04091048 - Optimize PRO Study
Withdrawn NCT03247465 - Image Fusion and Calcification Raising in Trans Aortic Valve Implantation N/A
Completed NCT03143686 - ACURATE TA™ Valve Implantation: SAVI Registry (Surveillance Plan #2011-02) (TA-SAVI)
Active, not recruiting NCT05182307 - DurAVR™ THV System: First-In-Human Study N/A
Active, not recruiting NCT03466918 - China S3: Safety and Effectiveness of Edwards Lifesciences SAPIEN 3 THV in the Chinese Population N/A
Completed NCT01819181 - Women's INternational Transcatheter Aortic Valve Implantation Registry
Completed NCT04331145 - Platelet REACtivity According to TICagrelor Dose After Transcatheter AorticValve Implantation Phase 4
Recruiting NCT02803294 - Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population Phase 4
Recruiting NCT04861805 - Pivotal Study of the Vienna Transcatheter Self Expandable Aortic Valve SE System N/A
Withdrawn NCT02088021 - Assessment of the St. Jude Medical PorticoTM Re-sheathable Aortic Valve System - Alternative Access N/A
Terminated NCT02759237 - The Medtronic Transcatheter Aortic Valve Implant System (CoreValve System Family) Post Marketing Surveillance (PMS) (CoreValve India PMS) N/A
Recruiting NCT01794832 - Severe Aortic Stenosis in Patients Referred for Valve Surgery N/A
Completed NCT02424370 - Geriatric Evaluation to Predict Mortality and Functional Recovery After Trans Aortic Valve Implantation
Completed NCT01493284 - Portico TAVI Implant With Transfemoral Delivery System N/A
Active, not recruiting NCT05712161 - Use of DurAVR™ THV System in Subjects With Severe Aortic Stenosis: Early Feasibility Study N/A
Completed NCT02664649 - Anti-Thrombotic Strategy After Trans-Aortic Valve Implantation for Aortic Stenosis Phase 3
Completed NCT01487330 - First in Human Experience of the St. Jude Medical TAVI Valve and Delivery System N/A
Active, not recruiting NCT04722250 - SMall Annuli Randomized To Evolut™ or SAPIEN™ Trial N/A