Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02454920
Other study ID # 20150332
Secondary ID
Status Completed
Phase N/A
First received May 19, 2015
Last updated June 28, 2017
Start date May 2015
Est. completion date January 2016

Study information

Verified date June 2017
Source University of Miami
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

Study designed to determine the ability and accuracy of anterior segment optical coherence tomography (AS-OCT) to measure the distance between the corneoscleral limbus and the insertion site of the extraocular muscles (EOM) in adults with and without previous strabismus surgery. And to compare in surgical patients the pre-operative AS-OCT limbal-muscle insertion distance measurement to the intraoperative limbal-muscle insertion measurement using calipers (gold standard).


Description:

The treatment of strabismus is often surgical. A better surgical plan would be possible if the exact limbus-insertion distance of the extraocular muscles was known. The clinical ophthalmologic examination, such as slit lamp biomicroscopy, cannot elucidate the muscle insertion position prior to surgery. This information is especially important in patients who have undergone prior strabismus surgery. In these patients, previous surgical data may not be available or the muscle insertion may be in a different location than expected. Thus, a preoperative imaging study that could accurately locate the muscle insertion may be useful for designing the surgical plan, possibly improving the success of the surgery, and reducing operative time and intraoperative complications.

Previous studies that used computed tomography (CT) scans and high-resolution magnetic resonance imaging (MRI), have failed to reliably detect the rectus muscle insertions. Ocular ultrasound allows anatomic visualization of the EOM, but has a low image resolution. Ultrasound biomicroscopy (UBM), can accurately measure the limbus-insertion distance, however, it induces significant measurement errors due to the pressure applied to the globe during examination. The recent advances in AS-OCT imaging allow non-invasive, detailed, cross-sectional examination of anterior segment structures by generating a two-dimensional high resolution image from a reflected light beam. Two previous studies have successfully used AS-OCT to analyze EOM insertions, but the number of participants was small and patients with previous strabismus muscle surgery were not included.

The investigators purpose is to gather limbus-EOM insertion distance data using the AS-OCT in a greater number of patients, include patients who have undergone previous strabismus procedures, and correlate AS-OCT measurements with intraoperative findings in those patients undergoing strabismus surgery.

Procedures

1. After recruitment, a written consent will be obtained from subjects who agree to participate.

2. A review of medical records will be performed to obtain demographics data, type of strabismus, history of previous eye surgery, etc (see Data Collection Sheet)

3. AS-OCT imaging of the rectus muscles will be performed in all patients using the Visante (Visante AS-OCT; Carl Zeiss Meditec) and/or Heidelberg Spectralis (Spectralis AS-OCT; Heidelberg Engineering) instruments.

4. For patients undergoing strabismus surgery, the distance from the corneoscleral limbus to the insertion site of the rectus muscles will be measured with calipers at the time of the surgery.

5. After the surgery, AS-OCT imaging of the rectus muscles will be performed during routinely scheduled post-operative clinic visits.

All acquired images will be stored in the Bascom Palmer Eye Institute MERGE HealthCare Completes Acquisition of Ophthalmic Imaging Systems (OIS), a clinical imaging storage system, which is secured against unauthorized access. All background information will be entered into REDCAP data capturing system by one of the investigators and be accessible only to the investigators (http://www.project-redcap.org/).

The AS-OCT devices that will be used are commercially available, FDA approved, and routinely used in clinical settings to evaluate the anterior and posterior segments of the eye. There are no experimental imaging procedures planned for the purpose of this study. All imaging acquisition protocols have been well-established and are non-invasive. There is no contact with the eye during image acquisition. This exposes the subjects to no greater than minimal risk as the result of participating in this study.

All eligible adult patients who are undergoing strabismus evaluation at the Bascom Palmer Eye Institute will be invited to participate. The consent processes will occur during the clinic visit. The study does not involve any additional clinic visits. The patient will have ample opportunity to discuss the study, review the consent form, and sign the consent form during the course of the visit. This study will follow the SOP: Informed Consent Process for Research (HRP-090).

Non-English Speaking Subjects We will exclude patients whose English proficiency precludes reading the form and understanding its contents.


Recruitment information / eligibility

Status Completed
Enrollment 72
Est. completion date January 2016
Est. primary completion date December 2015
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- All patients age = 18 years undergoing a strabismus evaluation at the Bascom Palmer Eye Institute will be invited to participate. Members of the study team will be involved in the clinical evaluation. The physician will determine if the patient has strabismus and whether strabismus surgery is advisable.

Exclusion Criteria:

1. Patient who is unwilling to participate the study.

2. A clinical scenario in which AS-OCT examination is not likely to be successful (e.g. an uncooperative patient).

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
University of Miami

References & Publications (3)

Dai S, Kraft SP, Smith DR, Buncic JR. Ultrasound biomicroscopy in strabismus reoperations. J AAPOS. 2006 Jun;10(3):202-5. — View Citation

Liu X, Wang F, Xiao Y, Ye X, Hou L. Measurement of the limbus-insertion distance in adult strabismus patients with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci. 2011 Oct 28;52(11):8370-3. doi: 10.1167/iovs.11-7752. — View Citation

Park KA, Lee JY, Oh SY. Reproducibility of horizontal extraocular muscle insertion distance in anterior segment optical coherence tomography and the effect of head position. J AAPOS. 2014 Feb;18(1):15-20. doi: 10.1016/j.jaapos.2013.11.005. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Limbus to extraocular muscles insertion distance Measurement of the limbus to insertion distance with OCT Baseline measurement
Secondary Comparison between intra operative and OCT measurements of the distance from the limbus to extraocular muscles insertion Measurement of the limbus to insertion distance with OCT (mm) and measurement of the limbus to insertion distance with a caliper at time of surgery (mm) From date of baseline to date of surgery
See also
  Status Clinical Trial Phase
Completed NCT04432181 - Comparison of Deviation Types Among Astigmatic Children With Or Without Amblyopia
Completed NCT03596138 - Reliability and Reproducibility of Automated Angular Measurement in Strabismus
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Recruiting NCT04770519 - Genetic Studies of Strabismus, Nystagmus, and Associated Disorders
Completed NCT01512355 - The Effect of Dexmedetomidine on Decreasing Emergence Agitation and Delirium in Pediatric Patients Undergoing Strabismus Surgery N/A
Completed NCT00461656 - Povidone-iodine Antisepsis for Strabismus Surgery Phase 4
Completed NCT00535938 - MDs on Botox Utility (MOBILITY) N/A
Completed NCT01109459 - Multimodal Physician Intervention to Detect Amblyopia N/A
Not yet recruiting NCT06035757 - The Occurrence of Emergence Agitation in Pediatric Strabismus Surgery Phase 4
Completed NCT01430247 - Vision Screening for the Detection of Amblyopia N/A
Recruiting NCT04416776 - Validation of the Utility of Strabismus Intelligent Diagnostic System
Recruiting NCT04353960 - The Alaska Oculocardiac Reflex Study
Terminated NCT02246556 - Dichoptic Virtual Reality Therapy for Amblyopia in Adults Phase 1
Completed NCT01726842 - Amblyopia and Strabismus Detection Using a Pediatric Vision Scanner N/A
Completed NCT00001143 - Development of the Eye Motor System During the First 7 Months of Life in Infants With and Without a Family History of Cross-Eye N/A
Completed NCT04303832 - Exercise Interventions of Eye Muscles Post Strabismus Surgery N/A
Completed NCT03806270 - Hydroxyzine Dihydrochloride Premedication is a Necessity for Strabismus Surgery
Recruiting NCT05425589 - Adjustable Strabismus Surgery N/A
Completed NCT00559234 - Potential Research Participants for Future Studies of Inherited Eye Diseases N/A
Completed NCT02570555 - Strabismus Surgery and Driving Ability