Sleep Clinical Trial
Official title:
The Effect of Ergonomic Sleep Mask Usage on Sleep Quality and Comfort in Intensive Care Patients
Verified date | November 2022 |
Source | Bartin University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
In intensive care units, the sleep quality of patients decreases considerably due to reasons such as alarm sounds of some special devices, the number of healthcare professionals working in comparison to other clinics, their circulation is high, and the lights are constantly on.Studies conducted in intensive care units to facilitate the transition of patients to sleep and to improve sleep quality;has revealed that non-pharmacological applications increase sleep time and quality, reduce sleep disturbance,delirium,post-traumatic stress disorder and duration of stay in the intensive care unit.Although wearing earplugs and eye masks is a cost-effective and safe method and can improve perceived sleep quality in patients,eye masks and ear plugs are sometimes not comfortable.While the ear plugs dislocate during night sleep may cause the patients to wake up again,there are also situations such as the eye masks not being sized properly for the patients' eyes,and the part of the mask surrounding the head is thin and tense, disturbing the patient.By eliminating this situation that disturbs the patients, other solutions are needed to increase the quality of sleep without being affected by intensive care light and noise. The project was planned to determine the effect of the ergonomic sleep mask on the sleep quality and comfort of patients in surgical patients whose treatment and care continues in intensive care units.The sample of the project consists of 128 patients by performing power analysis.Patients will be divided into two groups as 64 randomized patients in the control and experimental groups by applying block randomization.While there is no application to the experimental and control groups on the first night, an ergonomic sleep mask will be worn to the experimental group,and an ear plug and eye mask will be worn to the control group.At the end of the first night and the second night, the sleep quality of the patients will be evaluated with the 'Richard Campell Sleep Scale' and their comfort levels with the 'Visual Analogue Scale'.The data of the project will be collected using the Patient Information Form prepared in accordance with the literature. In the analysis of the data,Mann-Whitney U test, t test in independent groups, one-way ANOVA test and correlation analysis will be done.
Status | Completed |
Enrollment | 128 |
Est. completion date | August 30, 2022 |
Est. primary completion date | July 30, 2022 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Acceptance for treat and care of intensive care unit following surgery - Inpatient stay in the first 24 hours - Volunteering to participate in the research - Being 18 years of age or older - Being able to communicate (patients with a minimum of Glaskow Coma Scale score of 12) - Stable vital signs (arterial blood pressure, heart rate, oxygen saturation, body temperature) Exclusion Criteria: - No surgical intervention - The length of stay in the intensive care unit after the surgery is not on the first day - Having head, neck, ear and eye surgery - Having eye and ear infections - Chronic sleep disorder experience - Sedation - Having an allergy - Depending on invasive or noninvasive mechanical ventilation - Using assistive hearing aids - Finding vision loss - No communication |
Country | Name | City | State |
---|---|---|---|
Turkey | Bartin University | Merkez | Bartin |
Lead Sponsor | Collaborator |
---|---|
Bartin University | Zonguldak Ataturk State Hospital |
Turkey,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | To compare the effects of using ergonomic sleep mask and ear plugs and eye mask on the comfort levels of patients in intensive care unit. | The effects on the comfort levels of the patients will be measured with the Visual Analog Scale.
Visual Analog Scale: Using a ruler, the score is determined by mea-suring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. Based on the distribution of pain VAS scores in post- surgical patients (knee replacement, hyster-ectomy, or laparoscopic myomectomy) who described their postoperative pain intensity as none, mild, moderate, or severe, the following cut points on the pain VAS have been recommended: no pain (0-4 mm), mild pain(5-44 mm), moderate pain (45-74 mm), and severe pain (75-100 mm) (11). Normative values are not available. The scale has to be shown to the patient otherwise it is an auditory scale not a visual one. |
1 year | |
Primary | To compare the effects of using ergonomic sleep mask and ear plugs and eye mask on sleep quality of patients in intensive care unit. | The effects on the sleep quality of the patients will be measured with the Richard-Campbell Sleep Scale.
Richard-Campbell Sleep Scale: Developed by Richards in 1987, the RCSQ is a 6-item scale that evaluates the depth of night sleep, the time it takes to fall asleep, the frequency of awakening, the time to stay awake when awakened, the quality of sleep, and the noise level in the environment. Each item is evaluated on a chart between 0 and 100 using the visual analog scale technique. A score of "0-25" from the scale indicates very bad sleep, and a score of "76-100" indicates very good sleep. The total score of the scale is evaluated over 5 items, and the 6th item, which evaluates the noise level in the environment, is excluded from the total score evaluation. As the score of the scale increases, the sleep quality of the patients also increases. The Cronbach a value of the scale developed by Richards was found to be 0.82. |
1 year | |
Secondary | To examine the effects of the type of anesthesia applied during the surgery on comfort of the patients staying in the intensive care units after surgery. | The effects on comfort of the patients will be measured with the Visual Analog Scale.
Visual Analog Scale: Using a ruler, the score is determined by mea-suring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. Based on the distribution of pain VAS scores in post- surgical patients (knee replacement, hyster-ectomy, or laparoscopic myomectomy) who described their postoperative pain intensity as none, mild, moderate, or severe, the following cut points on the pain VAS have been recommended: no pain (0-4 mm), mild pain(5-44 mm), moderate pain (45-74 mm), and severe pain (75-100 mm) (11). Normative values are not available. The scale has to be shown to the patient otherwise it is an auditory scale not a visual one. |
1 year | |
Secondary | To examine the effects of the type of anesthesia applied during the surgery on sleep quality of the patients staying in the intensive care units after surgery. | The effects on sleep quality of the patients will be measured with the Richard-Campbell Sleep Scale.
Richard-Campbell Sleep Scale: Developed by Richards in 1987, the RCSQ is a 6-item scale that evaluates the depth of night sleep, the time it takes to fall asleep, the frequency of awakening, the time to stay awake when awakened, the quality of sleep, and the noise level in the environment. Each item is evaluated on a chart between 0 and 100 using the visual analog scale technique. A score of "0-25" from the scale indicates very bad sleep, and a score of "76-100" indicates very good sleep. The total score of the scale is evaluated over 5 items, and the 6th item, which evaluates the noise level in the environment, is excluded from the total score evaluation. As the score of the scale increases, the sleep quality of the patients also increases. The Cronbach a value of the scale developed by Richards was found to be 0.82. |
1 year | |
Secondary | To examine the effects of the type of surgery applied to patients on the sleep quality of patients staying in the intensive care units after surgery. | The effects on the sleep quality of the patients will be measured with the Richard-Campbell Sleep Scale.
Richard-Campbell Sleep Scale: Developed by Richards in 1987, the RCSQ is a 6-item scale that evaluates the depth of night sleep, the time it takes to fall asleep, the frequency of awakening, the time to stay awake when awakened, the quality of sleep, and the noise level in the environment. Each item is evaluated on a chart between 0 and 100 using the visual analog scale technique. A score of "0-25" from the scale indicates very bad sleep, and a score of "76-100" indicates very good sleep. The total score of the scale is evaluated over 5 items, and the 6th item, which evaluates the noise level in the environment, is excluded from the total score evaluation. As the score of the scale increases, the sleep quality of the patients also increases. The Cronbach a value of the scale developed by Richards was found to be 0.82. |
1 year | |
Secondary | To examine the relationship between the socio-demographic characteristics of patients and their comfort status in the intensive care units. | The effects on the comfort of the patients will be measured with the Visual Analog Scale.
Visual Analog Scale: Using a ruler, the score is determined by mea-suring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. Based on the distribution of pain VAS scores in post- surgical patients (knee replacement, hyster-ectomy, or laparoscopic myomectomy) who described their postoperative pain intensity as none, mild, moderate, or severe, the following cut points on the pain VAS have been recommended: no pain (0-4 mm), mild pain(5-44 mm), moderate pain (45-74 mm), and severe pain (75-100 mm) (11). Normative values are not available. The scale has to be shown to the patient otherwise it is an auditory scale not a visual one. |
1 year | |
Secondary | To examine the relationship between the socio-demographic characteristics of patients and their sleep quality in the intensive care units. | The effects on the comfort of the patients will be measured with the Richard-Campbell Sleep Scale.
Richard-Campbell Sleep Scale: Developed by Richards in 1987, the RCSQ is a 6-item scale that evaluates the depth of night sleep, the time it takes to fall asleep, the frequency of awakening, the time to stay awake when awakened, the quality of sleep, and the noise level in the environment. Each item is evaluated on a chart between 0 and 100 using the visual analog scale technique. A score of "0-25" from the scale indicates very bad sleep, and a score of "76-100" indicates very good sleep. The total score of the scale is evaluated over 5 items, and the 6th item, which evaluates the noise level in the environment, is excluded from the total score evaluation. As the score of the scale increases, the sleep quality of the patients also increases. The Cronbach a value of the scale developed by Richards was found to be 0.82. |
1 year | |
Secondary | To examine the relationship between the patients' intensive care experiences and their sleep quality after the night they spent in the intensive care unit. | The effects on the sleep quality of the patients will be measured with the Richard-Campbell Sleep Scale.
Richard-Campbell Sleep Scale: Developed by Richards in 1987, the RCSQ is a 6-item scale that evaluates the depth of night sleep, the time it takes to fall asleep, the frequency of awakening, the time to stay awake when awakened, the quality of sleep, and the noise level in the environment. Each item is evaluated on a chart between 0 and 100 using the visual analog scale technique. A score of "0-25" from the scale indicates very bad sleep, and a score of "76-100" indicates very good sleep. The total score of the scale is evaluated over 5 items, and the 6th item, which evaluates the noise level in the environment, is excluded from the total score evaluation. As the score of the scale increases, the sleep quality of the patients also increases. The Cronbach a value of the scale developed by Richards was found to be 0.82. |
1 year | |
Secondary | To examine the relationship between the patients' intensive care experiences on comfort after the night they spent in the intensive care unit. | The effects on comfort of the patients will be measured with the Visual Analog Scale.
Visual Analog Scale: Using a ruler, the score is determined by mea-suring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. Based on the distribution of pain VAS scores in post- surgical patients (knee replacement, hyster-ectomy, or laparoscopic myomectomy) who described their postoperative pain intensity as none, mild, moderate, or severe, the following cut points on the pain VAS have been recommended: no pain (0-4 mm), mild pain(5-44 mm), moderate pain (45-74 mm), and severe pain (75-100 mm) (11). Normative values are not available. The scale has to be shown to the patient otherwise it is an auditory scale not a visual one. |
1 year |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04044495 -
Sleep, Rhythms and Risk of Alzheimer's Disease
|
N/A | |
Recruiting |
NCT06079853 -
Nurse Suicide: Physiologic Sleep Health Promotion Trial
|
N/A | |
Completed |
NCT05017974 -
Research on Improving Sleep During Pregnancy
|
N/A | |
Recruiting |
NCT05206747 -
Ottawa Sunglasses at Night for Mania Study
|
N/A | |
Enrolling by invitation |
NCT04253054 -
Chinese Multi-provincial Cohort Study-Beijing Project
|
||
Completed |
NCT04513743 -
Ultra Long-Term Sleep Monitoring Using UNEEG™ Medical 24/7 EEG™ SubQ
|
N/A | |
Completed |
NCT03251274 -
Bath Machine on Sleep Quality in Nursing Home
|
N/A | |
Completed |
NCT04102345 -
Lavender vs Zolpidem Sleep Quality During Diagnostic PSG
|
Early Phase 1 | |
Completed |
NCT03725943 -
Comparison of Dreem to Clinical PSG for Sleep Monitoring in Healthy Adults
|
N/A | |
Active, not recruiting |
NCT05062161 -
Sleep Duration and Blood Pressure During Sleep
|
N/A | |
Completed |
NCT04562181 -
Consistency Evaluation of the qCON, qNOX Indices and Bispectral Index
|
N/A | |
Completed |
NCT05576844 -
Ai Youmian (Love Better Sleep) for People Living With HIV
|
N/A | |
Completed |
NCT05102565 -
A Dyadic Telehealth Program for Alzheimer's Patients/Caregivers
|
N/A | |
Completed |
NCT04688099 -
Synovial Fluid Sleep Study
|
||
Recruiting |
NCT04171245 -
Prescribing Laughter for Sleep and Wellbeing in UAE University Students
|
N/A | |
Completed |
NCT03758768 -
The Effects of a Blue Monochromatic Light Intervention on Evening-type Individuals' Sleep and Circadian Rhythms
|
N/A | |
Completed |
NCT03163498 -
Evaluation of Sleep Pattern and Mood Profile in Hypertensive Patients
|
||
Completed |
NCT04093271 -
Investigating the Efficacy of Rest-ZZZ Formula in Healthy Participants With Difficulty Falling Asleep or Staying a Sleep
|
Phase 1 | |
Completed |
NCT03673397 -
The Acute Effect of Aerobic Exercise on Sleep in Patients With Depression
|
N/A | |
Completed |
NCT04120363 -
Trial of Testosterone Undecanoate for Optimizing Performance During Military Operations
|
Phase 4 |