Clinical Trial Summary

Sleep-related breathing disorders are highly prevalent and are usually treated with positive airway pressure (PAP) therapy. To determine the quality of therapy, PAP therapy devices measure the frequency of residual breathing events. For this purpose, breathing events of different classes are detected, counted and identified. This clinical investigation aims to evaluate the performance of prismaLINE devices based on the accuracy of the apnea-hypopnea index (AHI) recorded in the devices. During the PAP titration night, the AHI is similarly detected via polysomnography (PSG) device and a subsequent manual scoring of the recorded PSG data. The validation of the device AHI accuracy refers to the alignment with the manually scored AHI. Further goals of this clinical investigation are the confirmation of safety of the prismaLINE devices, the confirmation of performance and safety of LM full face masks (full face masks of the manufacturer Löwenstein Medical Technology), as well as the investigation of the influence of LM full face masks on therapy quality. The most relevant inclusion criteria are diagnosis of a sleep-related breathing disorder and indication for therapy with continuous positive airway pressure (CPAP). Treatment takes place with prismaLINE PAP therapy devices in combination with LM full face masks.


Clinical Trial Description

The duration of the clinical investigation per participant is two or three nights: diagnosis night with the following CPAP titration night. A further titration night (CPAP or APAP) might be necessary to find optimal therapy settings. But only the CPAP titration night with the best therapy result will be analysed. The titration night is performed according to a predefined titration scheme. Therapy pressure will be gradually increased until breathing events are treated sufficiently. Due to the need of a certain number of remaining breathing events for sufficient performance evaluation, therapy pressure will be gradually reduced after reaching the ideal pressure level to provoke additional breathing events. The titration night is additionally monitored and recorded via polysomnography (PSG). No significant negative impact on patients' condition based on subtherapeutic phase is expected. After the end of the clinical investigation participants will be treated according to clinical routine. The performance of the prismaLINE therapy device will be evaluated by the accuracy of the alignment between the device AHI and the manually scored PSG AHI (using AASM hypopnea scoring rule 1A). The alignment between device AHI versus PSG AHI will be defined for coincident titration night recordings of both, therapy and PSG device. The accuracy of the device AHI is defined by the absolute or relative deviation from the manually scored PSG AHI (ΔAHI_rel or ΔAHI_abs) and classified in acceptable, good, very good or unacceptable. The maximum deviation (ΔAHI_rel or ΔAHI_abs) is used throughout to determine the corresponding device AHI values for each category. To achieve the primary endpoint, the proportion of the investigation population with an at least acceptable device AHI must be ≥ 80%. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06317077
Study type Interventional
Source Löwenstein Medical Technology GmbH & Co. KG
Contact Regina Schaefer
Phone 0151-72421355
Email regina.schaefer@loewensteinmedical.com
Status Not yet recruiting
Phase N/A
Start date May 15, 2024
Completion date May 15, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05477719 - Effect of Compression Stockings on the Number of Apneas/Hypopneas Per Hour of Sleep in Patients With Syndrome Obstructive Sleep Apnea/Hypopnea as Compared to no Treatment N/A
Completed NCT04979234 - A Single Centre, Prospective Feasibility Study to Evaluate the Efficacy of an Endoluminal-suturing Device (Endomina) on Severe Obstructive Sleep Apnea Syndrome N/A
Terminated NCT02735694 - Cycloserine in the Treatment of Sleep Apnea Phase 1
Active, not recruiting NCT02470182 - Screening for Sleep Disordered Breathing With Minimally Obtrusive Sensors
Completed NCT02088723 - Testing the Elevation as Sleep Apnea Treatment N/A
Completed NCT01457014 - Sleep Disordered Breathing and Chronic Pain N/A
Completed NCT00976417 - Mechanisms of Action of Adaptive Servoventilation N/A
Completed NCT00860743 - Respiratory and Autonomic Plasticity Following Intermittent Hypoxia Early Phase 1
Active, not recruiting NCT00371293 - The Effects of Obesity and Obstructive Sleep Apnea on Inflammation and Heart Disease N/A
Completed NCT00607893 - Efficacy of Continuous Positive Airway Pressure in Reducing Oxidative Stress in Individuals With Sleep Apnea N/A
Completed NCT00070681 - Outcomes of Sleep Disorders in Older Men Phase 3
Completed NCT00083798 - Family Linkage Study of Obstructive Sleep Apnea (OSA) in Iceland N/A
Completed NCT00089752 - Continuous Positive Airway Pressure to Improve Milder Obstructive Sleep Apnea N/A
Completed NCT00051363 - Apnea Positive Pressure Long-Term Efficacy Study Phase 3
Completed NCT00046670 - Sleep Disordered Breathing, APOE, and Lipid Metabolism N/A
Completed NCT00031239 - Sleep Apnea in Look AHEAD Participants - Ancillary to Look AHEAD N/A
Terminated NCT00006321 - Neurocognitive Function in Snoring Children N/A
Completed NCT00006323 - Neurobehavioral Consequences of Sleep Apnea in Children N/A
Completed NCT00005511 - SCOR in Neurobiology of Sleep--Intermediate Traits for Sleep Apnea N/A
Completed NCT00005275 - Sleep Heart Health Study (SHHS) Data Coordinating Center N/A