Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03782844
Other study ID # 2011 No. 5
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 2, 2019
Est. completion date October 15, 2019

Study information

Verified date May 2021
Source State Key Laboratory of Respiratory Disease
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Obstructive sleep apnea (OSA) is a common and frequently-occurring disease. The incidence of OSA is more than 4% in general population, and as high as 20% - 40% in the elderly. At present, CPAP machines commonly used for OSA treatment includes traditional pressure fixed single-level CPAP machine and automatic pressure regulation CPAP machine. Studies have shown that the CPAP treatment pressure of OSA patients is normally below 11 cmH2O. Since the condition of OSA patients and the required CPAP treatment pressure may change over time, a CPAP machine with automatic pressure regulation function may theoretically better meet the needs of treatment. However, a recent large-scale clinical study with an average follow-up of four years showed that there was little need to change CPAP treatment pressure after titration. Although different types of CPAP have different functions, the basic principle is to keep the upper airway open and unobstructed to eliminate sleep apnea and hypopnea by continuously applying positive pressure to the upper respiratory tract through an air pump. A complex CPAP machine with functions such as pressure regulation, boost delay, end-expiratory pressure release will cost more than a single-function CPAP machine. Some patients from poor areas, even with severe OSA, may give up treatment when they can not afford CPAP machines that have not yet been included in national health insurance in China. In view of the current economic level in China, it is urgent to find an inexpensive and effective CPAP machine for the treatment of OSA and related complications. Recently, Guangzhou Yinghui Medical Technology Co., Ltd.and State Key Laboratory of Respiratory Disease have developed a new simple CPAP machine. The CPAP treatment pressure is fixed at the factory to 6 cm H2O (SKL), 8 cm H2O (SKM) and 10 cm H2O (SKH). Compared to traditional CPAP machine, only a power switch button is attached on the body, and the additional adjustment devices including display screen are removed, which not only reduces the cost of the CPAP machine, but also facilitates the operation of patients.


Description:

Study Design: A randomized, cross-over and double blind study . Objective: To investigate the efficacy of simple device of continuous positive airway pressure (CPAP) in the treatment of obstructive sleep apnea (OSA). Methods: A randomized, cross-over and double blind study would be performed on 100 OSA patients using both simple CPAP and traditional CPAP during overnight polysomnography. Pressure for CPAP treatment would be manual titrated. The sleep apnea hypopnea index (AHI), arousal index (ArI), Oxygen desaturation Index (ODI), sleep structure and the preference of CPAP model were to be observed.


Recruitment information / eligibility

Status Completed
Enrollment 100
Est. completion date October 15, 2019
Est. primary completion date October 1, 2019
Accepts healthy volunteers No
Gender All
Age group 16 Years and older
Eligibility Inclusion Criteria: 1. Willing to participate after informed consent 2. Males and females, any race and aged=18yeras 3. Objectively confirmed OSA with an apnoea-hypopnoea- index (AHI)=5/h by overnight polysomnography Exclusion Criteria: 1. Central Sleep Apnoea/Cheyne Stokes Respiration 2. Opioid or sedative use; Alcohol abuse 3. Nasal congestion or tonsils more than ? degrees enlarged 4. Optimal treatment CPAP pressure over 10cmH2O 5. Poor understanding or being disabled

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Simple CPAP+Conventional fixed CPAP
Patients used simple CPAP and conventional fixed CPAP during overnight polysomnography.
Simple CPAP + Auto CPAP
Patients used simple CPAP and Auto CPAP during overnight polysomnography.

Locations

Country Name City State
China The First Affiliated Hospital of Guangzhou Medical University Guangzhou Guangdong

Sponsors (1)

Lead Sponsor Collaborator
State Key Laboratory of Respiratory Disease

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary Apnea Hypopnea Index Total number of apneas and hypopneas×60/total sleep time One full night
Primary Arousal Index Total number of arousals×60/total sleep time One full night
Primary Oxygen Desaturation Index Total number of oxygen desaturations=3%×60/total sleep time One full night
Primary Sleep structure Sleep stage distribution(N1, N2, N3, NREM) One full night
Primary Adverse effects Using questionnaire to assess adverse effects including dyspnea, noise, bloating, et al Onefull night
See also
  Status Clinical Trial Phase
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT04912635 - Evaluation of a Health Dashboard Intervention to Improve Engagement With CPAP Therapy in PAP-Naïve Patients: Project Neo N/A
Not yet recruiting NCT05939934 - Impact of the Mandibular Advancement Device on Sleep Apnea During CPAP Withdrawal N/A
Enrolling by invitation NCT02290236 - Monitored Saturation Post-ICU N/A
Terminated NCT02269774 - Origin of Premature Atrial Beats Induced by Simulated Obstructive Sleep Apnea N/A
Completed NCT02088723 - Testing the Elevation as Sleep Apnea Treatment N/A
Completed NCT02261857 - 3D-Printed CPAP Masks for Children With Obstructive Sleep Apnea Early Phase 1
Completed NCT01943708 - Novel Auto-continuous Positive Airway Pressure (CPAP) Validation Phase 3
Completed NCT01181570 - Efficacy and Safety of Adalimumab in Patients With Psoriasis and Obstructive Sleep Apnea Phase 4
Completed NCT00273754 - The Effect of Caffeine on Postextubation Adverse Respiratory Events in Children With Obstructive Sleep Apnea (OSA). Phase 2
Recruiting NCT02166879 - Undetected Sleep Apnea in the Postanesthesia Acute Care Unit (PACU)
Recruiting NCT04963192 - Integrated Management of Chronic Respiratory Diseases N/A
Completed NCT05056766 - How Does the Clinical and Paraclinical Efficacy of an Oral Appliance Evolved According to Propulsion: Control With Each mm of Advancement
Completed NCT04846400 - Pilot Study of a Self-Supporting Nasopharyngeal Airway in Hypotonia N/A
Recruiting NCT04314492 - Intracapsular Tonsillectomy in the Treatment of Obstructive Sleep Apnea in Adults N/A
Completed NCT05175287 - OSA (oRisk of Obstructive Sleep Apnea and Traffic Accidents Among Bus Drivers in Ecuador: is There a Significant Association
Active, not recruiting NCT03431038 - Cross-sectional Study of Prevalence Rate of Abdominal Aortic Aneurysm in OSAHS Patients From BTCH N/A
Enrolling by invitation NCT03075787 - Cardiovascular Variability and Heart Rate Response Associated With Obstructive Sleep Apnea N/A
Completed NCT03300037 - HYpopnea and Apnea Detection and Treatment Performance of a New cardiOreSpiratory Holter Monitor N/A
Recruiting NCT06097949 - AcuPebble to Remotely Monitor Patients With OSA on CPAP Therapy