Clinical Trials Logo

Clinical Trial Summary

ME-APDS is a device (software-based with hardware) developed by Magentiq Eye LTD and intended to support the decision of the endoscopist on polyps which appear in the colonoscopy video during the colonoscopy procedure. This randomized two arm colonoscopy trial will mainly compare APC and APE between Magentiq Eye Assisted Colonoscopy (MEAC) and Conventional Colonoscopy (CC) in patients referred for either screening or surveillance colonoscopies.


Clinical Trial Description

The primary objective of the present study is to compare the number of Adenomas Per Colonoscopy (APC) and the Adenomas Per Extraction (APE) between the Magentiq Eye-Assisted Colonoscopy (MEAC) and Conventional Colonoscopy (CC). These are also the co-primary endpoints. The secondary endpoints are Adenoma Miss Rate (AMR, tested on part of the total study population) and Adenoma Detection Rate (ADR). This study mainly hypothesizes that more adenomas will be detected in MEAC compared to CC (higher APC in MEAC compared to CC), and that the reduction of APE in MEAC compared to CC (if there will be a reduction) will be limited. The study also assumes that AMR will be reduced in MEAC compared to CC and that ADR will increase to some level in MEAC compared to CC. The study will include 952 subjects . Eligible patients will be randomized in a 1:1 ratio into two groups, group A and B. In group A, patients will be examined with CC. Patients in group B will be examined using MEAC. Immediately after the randomization, a sub-randomization will be performed on whether an immediate second examination (for AMR calculation) will be conducted or not (136 patients will undergo second examination). The colonoscopy will be performed in accordance with the standard of care of each medical center in either MEAC or CC. After the colonoscopy procedure patients will be observed at the endoscopy unit until the discharge criteria are met as per the standard clinical protocol of the medical center. After here, they will be discharged by the treating physician. Study follow-up period will be up to 30-days post-colonoscopy to register (serious) adverse events and it will be in accordance with the standard of care of medical center. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04640792
Study type Interventional
Source Magentiq Eye LTD
Contact
Status Completed
Phase N/A
Start date October 1, 2020
Completion date February 10, 2022

See also
  Status Clinical Trial Phase
Completed NCT03637712 - Deep-Learning for Automatic Polyp Detection During Colonoscopy N/A
Recruiting NCT04894708 - Study on the Use of Artificial Intelligence (Fujifilm) for Polyp Detection in Colonoscopy N/A
Recruiting NCT04422548 - Does AI-assisted Colonoscopy Improve Adenoma Detection in Screening Colonoscopy? N/A
Not yet recruiting NCT06333392 - Total Underwater Colonoscopy (TUC) for Improved Colorectal Cancer Screening: A Randomized Controlled Trial N/A
Completed NCT03458390 - Use of a Colon Irrigation Device as a Preparation for a Colon Visualization Procedure N/A
Completed NCT02194959 - Peer Patient Navigation for Colon Cancer Screening N/A
Terminated NCT01782014 - Comparison of Adenoma Detection Rate Among Water, Carbon Dioxide and Air Methods of Minimal Sedation Colonoscopy Phase 3
Completed NCT01838408 - Evaluation of Proposed EZ2go Complete Bowel Cleansing System N/A
Completed NCT04838951 - Effect of Real-time Computer-aided System (ENDO-AID) on Adenoma Detection in Endoscopist-in-training N/A