SARS-CoV-2 Infection Clinical Trial
Official title:
EuGeni SARS-CoV-2 Antigen Rapid Diagnostic Test Clinical Performance Study
Rapid antigen detection (RAD) tests are used to perform rapid diagnosis of SARS-CoV-2 infection based on a qualitative approach. RAD tests detect the viral antigen by the immobilized coated SARS-CoV-2 antibody placed on the device. The results of these tests are available in a short time, reducing the workload in diagnostic hospitals and laboratories and improving the turn-around time. EuGeni SARS-CoV-2 Antigen Rapid Diagnostic Test is an in vitro Diagnostic (IVD) medical device intended to be used for the qualitative detection of SARS-CoV-2 nucleocapsid antigen. The result from this IVD test identifies the presence or absence of the SARS-CoV-2 antigen as an aid for the diagnosis of COVID-19 infection.
The EuGeni SARS-CoV-2 Antigen (Ag) Rapid Detection Test (RDT) is a test strip based on lateral flow technology which utilizes nanoparticles, doped with europium, as the fluorescence reporter system. The test strip is housed in a cassette which is read by the EuGeni AX-2X-S Reader, a portable instrument that reads EuGeni fluorescent lateral flow tests. The test line contains an immobilized monoclonal mouse antibody to capture SARS-CoV-2 antigen and the control line contains an immobilized control anti-mouse antibody. The test sample is added to the sample well of the test cassette and then reconstitutes the dried europium nanoparticle antibody conjugate from the conjugate pad. The sample flows along the test strip by capillary action. If the sample contains SARS-CoV-2 antigen, it binds to the antibody-labelled europium nanoparticle. When the sample flows past the test line, the europium bound antigen is captured by the second anti-SARS-CoV-2 antibody immobilized on the test line. A fluorescent signal detected by the EuGeni AX-2X-S Reader at this test line indicates that the specimen is SARS-CoV-2 antigen Positive. If the sample does not contain SARS-CoV-2 antigen, the europium-labelled anti-antigen antibody will not bind to the test line. This indicates that the specimen is SARS-CoV-2 antigen Negative. The sample continues to flow along the strip and when it passes over the control line, antibody-labelled europium nanoparticles are captured by the immobilized anti-mouse antibody. The control line must be detected by the EuGeni AX-2X-S Reader for the test to be valid. If the control line is not detected, the test is considered invalid and must be repeated using another test cassette. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Terminated |
NCT04555096 -
A Trial of GC4419 in Patients With Critical Illness Due to COVID-19
|
Phase 2 | |
Completed |
NCT04593641 -
This is a Phase 1 Study to Evaluate the Safety,Tolerability and Virology of CT P59 in Patients With Mild Symptoms of Symptoms of Coronavirus Disease (COVID-19)
|
Phase 1 | |
Recruiting |
NCT05200754 -
Trial With or Without Infusion of SARS-CoV-2 Antibody Containing Plasma in High-Risk Patients With COVID-19
|
Phase 2 | |
Completed |
NCT04583995 -
A Study Looking at the Effectiveness, Immune Response, and Safety of a COVID-19 Vaccine in Adults in the United Kingdom
|
Phase 3 | |
Recruiting |
NCT06255860 -
SARS-COV-2 Reinfection and Multisystem Inflammatory Syndrome in Children (MIS-C) Risk: Matched Case-control Study
|
||
Recruiting |
NCT04516811 -
Therapeutic Use of Convalescent Plasma in the Treatment of Patients With Moderate to Severe COVID-19
|
Phase 3 | |
Recruiting |
NCT05012826 -
Osteopathy and Physiotherapy Compared to Physiotherapy Alone on Fatigue and Functional Status in Long COVID
|
N/A | |
Completed |
NCT05007236 -
Study to Evaluate the Efficacy and Safety of Oral RP7214, a DHODH Inhibitor, in Patients With Symptomatic Mild COVID-19 Infection.
|
Phase 2 | |
Recruiting |
NCT06026514 -
Phase I Safety Study of B/HPIV3/S-6P Vaccine Via Nasal Spray in Adults
|
Phase 1 | |
Completed |
NCT05523739 -
Safety and Efficacy Study of STI-1558 in Healthy Adults and SARS-CoV-2-Positive Patients
|
Phase 1 | |
Suspended |
NCT04738136 -
Safety, Tolerability and Efficacy Of S-1226 in Moderate Severity Covid-19 Bronchiolitis/Pneumonia
|
Phase 2 | |
Recruiting |
NCT04584658 -
Dysphagia and Dysphonia Outcomes in SARS CoV-2 (COVID-19) Infection (DYADS Study)
|
||
Recruiting |
NCT04547114 -
Breath Analysis for SARS-CoV-2 in Infected and Healthy Subjects
|
||
Completed |
NCT05119348 -
Transmission of Coronavirus Disease 2019 (COVID19) in Crowded Environments
|
N/A | |
Completed |
NCT05096962 -
COVID-19: SARS-CoV-2-CZ-PREVAL-II Study
|
||
Recruiting |
NCT04534400 -
Automated Quantification of Radiologic Pulmonary Alteration During Acute Respiratory Failure
|
||
Completed |
NCT04527354 -
Pilot Study to Assess Efficacy and Safety of Treamid in the Rehabilitation of Patients After COVID-19 Pneumonia
|
Phase 2 | |
Completed |
NCT04583982 -
ImmuneSense™ COVID-19 Study
|
||
Completed |
NCT05077176 -
Phase 3 Booster Vaccination Against COVID-19
|
Phase 3 | |
Completed |
NCT05584189 -
COVID-19 MP Biomedicals Rapid SARS-CoV-2 Antigen Test Usability
|
N/A |