Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05318638
Other study ID # 80144
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date October 17, 2022
Est. completion date December 2024

Study information

Verified date September 2023
Source Roessingh Research and Development
Contact G. Prange, PhD
Phone +31 88875777
Email g.prange@rrd.nl
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The hand is important to perform activities of daily living (ADL). However, many people experience a loss of hand function as result of a traumatic brain injury, spinal cord injury, stroke or orthopedic problems, or due to ageing. To improve hand function, or reduce its decline, one can benefit from exercise therapy or use of assistive aids to improve ADL independence. A promising innovative approach combining both is a wearable soft-robotic glove that supports hand grip. With this glove, performance of functional activities can be supported directly, while also facilitating repeated use of the affected arm and hand during functional daily activities. One of our previous studies showed that besides a direct support effect, a therapeutic effect on performance was found after several weeks of using the soft-robotic glove as support during ADL. However, several participants reported complaints of increased pain and/or overload, mainly at the beginning of the trial. Clinicians suspect that a (too) high intensity of hand use compared to normal is contributing to this observation. This might be related to more fatigue experienced when using the glove in high-demand tasks, due to a larger movement capacity (faster, further, more repetitions) and can be associated with decreased blood perfusion/lower saturation levels at muscular level and altered muscle activation and movement coordination. Therefore, the primary objective is to examine the effect of use of the assistive soft-robotic glove during strenuous ADL tasks on the kinematic movement profile, compared to not using the soft-robotic glove. Secondary objectives are to examine whether pain or discomfort is experienced in strenuous activities with the soft-robotic glove as well as the characteristics and locations of such pain/discomfort, and to examine whether use of the glove is associated with increased handgrip strength, larger number of ADL task repetitions, diminished blood perfusion / reduced tissue saturation at the muscle and/or changes in muscle activity.


Description:

A promising innovative approach to improve hand function is to integrate exercise therapy with support of activities of daily life using an assistive device. This is possible using a wearable soft-robotic glove that supports hand grip. With this glove, performance of functional activities can be supported directly, while also facilitating repeated use of the affected arm and hand during functional daily activities. One of our previous studies showed that besides a direct support effect, a therapeutic effect on performance was found after several weeks of using the soft-robotic glove as support during ADL. However, several participants reported complaints of increased pain and/or overload, mainly at the beginning of the trial. Clinicians suspect that a (too) high intensity of hand use compared to normal is contributing to this observation. This might be related to more fatigue experienced when using the glove in high-demand tasks, due to a larger movement capacity (faster, further, more repetitions) and can be associated with decreased blood perfusion/lower saturation levels at muscular level and altered muscle activation and movement coordination. The primary objective is to examine the effect of use of the assistive soft-robotic glove during strenuous ADL tasks on the kinematic movement profile, compared to not using the soft-robotic glove. Secondary objectives are to examine whether pain or discomfort is experienced in strenuous activities with the soft-robotic glove as well as the characteristics and locations of such pain/discomfort, and to examine whether use of the glove is associated with increased handgrip strength, larger number of ADL task repetitions, diminished blood perfusion / reduced tissue saturation at the muscle and/or changes in muscle activity. The study is set-up as a cross-sectional intervention study with one measurement session, where participants will perform maximum handgrip strength tests and high-demand ADL-tasks with and without the soft-robotic glove. The aim is to include 20 participants in total, 10 of which will be frail elderly and the other 10 will be neuromuscular patients, all suffering from reduced hand function. All participants will perform each movement task with and without the soft-robotic glove. The soft-robotic glove used in the study is the Carbonhand system (Bioservo Technologies, Sweden). It is a CE-marked medical device and it consists of a glove that supports finger flexion via sewn-in tendons and a control unit housing the actuators that pull on the tendons and the batteries. The grip support is activated by applying very light pressure on sensors in the fingertips of the glove, and de-activated by releasing the pressure on the sensors. After execution of all tasks with and without glove, differences in outcome measures will be compared between glove conditions.


Recruitment information / eligibility

Status Recruiting
Enrollment 20
Est. completion date December 2024
Est. primary completion date December 2024
Accepts healthy volunteers No
Gender All
Age group 18 Years to 90 Years
Eligibility Inclusion Criteria: - Frail elderly with reduced hand function: - Age between 65 and 90 years - Experience difficulties in performing ADL due to a decline in hand function - Able to make a pinch grip between thumb and middle or ring finger - Sufficient cognitive status to understand two-step instructions - Having (corrected to) normal vision - Able to provide written informed consent - Neuromuscular patients: - Age between 18 and 80 years - Experience difficulties in performing ADL due to a decline in hand function that can be attributed to a diagnosed neuromuscular disease - Being in a chronic and stable phase of disease - Able to make a pinch grip between thumb and middle or ring finger - Sufficient cognitive status to understand two-step instructions - Having (corrected to) normal vision - Able to provide written informed consent Exclusion Criteria: - Frail elderly with reduced hand function: - Currently receiving treatment for a disease affecting arm/hand function - Used the CarbonHand system in the past 3 months - Severe sensory problems of the most-affected hand - Severe acute pain of the most-affected hand - Wounds on the hands that can provide a problem when using the glove - Severe contractures limiting passive range of motion - Severe spasticity of the hand (=2 points on Ashworth Scale) - Insufficient knowledge of the Dutch language to understand the purpose or methods of the study - Neuromuscular patients: - Severe sensory problems of the most-affected hand

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Soft robotic glove
The soft-robotic glove used in the study is the Carbonhand system (Bioservo Technologies, Sweden). It is a CE-marked medical device and it consists of a glove that supports finger flexion via sewn-in tendons and a control unit housing the actuators that pull on the tendons and the batteries. The grip support is activated by applying very light pressure on sensors in the fingertips of the glove, and de-activated by releasing the pressure on the sensors.

Locations

Country Name City State
Netherlands Roessingh Research and Development Enschede Overijssel

Sponsors (1)

Lead Sponsor Collaborator
Roessingh Research and Development

Country where clinical trial is conducted

Netherlands, 

Outcome

Type Measure Description Time frame Safety issue
Other Subject characteristics Age
Sex
Most-affected side
Dominant side
Impairment/ disorder and date of diagnosis
At the start of the measurement session, taking about 5 minutes
Primary Kinematic movement profile during performance of strenuous ADL task The kinematic movement profile during performance of strenuous ADL task, characterized by the following parameters as assessed using 3D marker-based motion capture: • Total movement duration
Duration of movement phases
Movement smoothness
Trunk displacement
Peak hand velocity
Time to peak velocity of reach phase
Hand opening
Joint excursion of the elbow
Joint excursion of the wrist
Endpoint straightness
Endpoint error
1-2 hours during the measurement session
Secondary Experienced pain/discomfort rating + description Discomfort and pain in the hand experienced by the participants will be assessed using a report form, indicating the amount of experienced pain and/or discomfort (using Visual Analogue Scales), and in case of discomfort or pain, a map of the hands to localize the pain/discomfort and a description of its sensation as well as an assumed cause. This will be done separately for each area in which discomfort and/or pain is reported. Twice during the measurement session, after completion of both conditions, with a duration of 5-10 minutes.
Secondary Perceived exertion and confidence in grip rating Perceived exertion/fatigue after the strenuous ADL tasks will be assessed using the Borg Rating Scale of Perceived Exertion. An additional question assesses the participants' confidence in their grip on the object as experienced during the ADL task performance. Twice during the measurement session, after completion of both conditions, with a duration of 5-10 minutes.
Secondary Maximal handgrip strength The maximal handgrip strength will be measured with a custom-made cylindrical dynamometer, recording the maximum force a person can exert on the dynamometer by forcefully gripping the cylinder. This will be done three times, if the last attempt is done with higher force than the second-to-last attempt, another attempt will be added, until the last value is lower than the second-to-last value. 1-2 hours during the measurement session
Secondary Handgrip endurance Handgrip endurance will also be measured with a custom-made cylindrical dynamometer. It will be measured in a static situation, by prolonged max contraction of hand grip during 30 seconds. 1-2 hours during the measurement session
Secondary Number of repetitions achieved during ADL task The number of repetitions achieved during execution of the ADL task (i.e., number of times the task was completed succesfully) in the four different conditions (no glove and unsupported max weight, no glove and supported max weight, glove and unsupported max weight, glove and supported max weight) will be recorded. 1-2 hours during the measurement session
Secondary Muscle tissue oxygen saturation The muscle oxygen saturation in the forearm is measured during the ADL task execution and handgrip strength and endurance tests using a NIRS sensor placed over the M. flexor radialis and ulnaris and the M. flexor digitorum superficialis, secured with Velcro straps around the forearm. 1-2 hours during the measurement session
Secondary Amplitude, on/off times and median frequency of muscle activity Muscle activity parameters will be calculated from surface EMG recordings of Abductor pollicis brevis, Extensor digitorum, Extensor carpi radialis, Extensor carpi ulnaris, Extensor pollicis brevis/longus, Flexor carpi ulnaris, Flexor carpi radialis 1-2 hours during the measurement session
See also
  Status Clinical Trial Phase
Active, not recruiting NCT06287502 - Efficacy of Structured Exercise-Nutritional Intervention on Sarcopenia in Patients With Osteoporosis N/A
Recruiting NCT05063279 - RELIEF - Resistance Training for Life N/A
Completed NCT03644030 - Phase Angle, Lean Body Mass Index and Tissue Edema and Immediate Outcome of Cardiac Surgery Patients
Recruiting NCT06143592 - Inspiratory Muscle Training on Balance, Falls and Diaphragm Thickness in the Elderly N/A
Terminated NCT04350762 - Nutritional Supplementation in the Elderly With Weight Loss N/A
Enrolling by invitation NCT05953116 - Managing the Nutritional Needs of Older Filipino With Due Attention to Protein Nutrition and Functional Health Study N/A
Recruiting NCT04028206 - Resistance Exercise or Vibration With HMB for Sarcopenia N/A
Enrolling by invitation NCT03297632 - Improving Muscle Strength, Mass and Physical Function in Older Adults N/A
Completed NCT04015479 - Peanut Protein Supplementation to Augment Muscle Growth and Improve Markers of Muscle Quality and Health in Older Adults N/A
Completed NCT03234920 - Beta-Hydroxy-Beta-Methylbutyrate (HMB) Supplementation After Liver Transplantation N/A
Recruiting NCT03998202 - Myopenia and Mechanisms of Chemotherapy Toxicity in Older Adults With Colorectal Cancer
Recruiting NCT04717869 - Identifying Modifiable PAtient Centered Therapeutics (IMPACT) Frailty
Completed NCT05497687 - Strength-building Lifestyle-integrated Intervention N/A
Completed NCT03119610 - The Physiologic Effects of Intranasal Oxytocin on Sarcopenic Obesity Phase 1/Phase 2
Recruiting NCT05711095 - The Anabolic Properties of Fortified Plant-based Protein in Older People N/A
Recruiting NCT05008770 - Trial in Elderly With Musculoskeletal Problems Due to Underlying Sarcopenia - Faeces to Unravel Gut and Inflammation Translationally
Not yet recruiting NCT05860556 - Sustainable Eating Pattern to Limit Malnutrition in Older Adults
Recruiting NCT04522609 - Electrostimulation of Skeletal Muscles in Patients Listed for a Heart Transplant N/A
Recruiting NCT04545268 - Prehabilitation for Cardiac Surgery in Patients With Reduced Exercise Tolerance N/A
Recruiting NCT03160326 - The QUALITY Vets Project: Muscle Quality and Kidney Disease