Clinical Trials Logo

Clinical Trial Summary

The hand is important to perform activities of daily living (ADL). However, many people experience a loss of hand function as result of a traumatic brain injury, spinal cord injury, stroke or orthopedic problems, or due to ageing. To improve hand function, or reduce its decline, one can benefit from exercise therapy or use of assistive aids to improve ADL independence. A promising innovative approach combining both is a wearable soft-robotic glove that supports hand grip. With this glove, performance of functional activities can be supported directly, while also facilitating repeated use of the affected arm and hand during functional daily activities. One of our previous studies showed that besides a direct support effect, a therapeutic effect on performance was found after several weeks of using the soft-robotic glove as support during ADL. However, several participants reported complaints of increased pain and/or overload, mainly at the beginning of the trial. Clinicians suspect that a (too) high intensity of hand use compared to normal is contributing to this observation. This might be related to more fatigue experienced when using the glove in high-demand tasks, due to a larger movement capacity (faster, further, more repetitions) and can be associated with decreased blood perfusion/lower saturation levels at muscular level and altered muscle activation and movement coordination. Therefore, the primary objective is to examine the effect of use of the assistive soft-robotic glove during strenuous ADL tasks on the kinematic movement profile, compared to not using the soft-robotic glove. Secondary objectives are to examine whether pain or discomfort is experienced in strenuous activities with the soft-robotic glove as well as the characteristics and locations of such pain/discomfort, and to examine whether use of the glove is associated with increased handgrip strength, larger number of ADL task repetitions, diminished blood perfusion / reduced tissue saturation at the muscle and/or changes in muscle activity.


Clinical Trial Description

A promising innovative approach to improve hand function is to integrate exercise therapy with support of activities of daily life using an assistive device. This is possible using a wearable soft-robotic glove that supports hand grip. With this glove, performance of functional activities can be supported directly, while also facilitating repeated use of the affected arm and hand during functional daily activities. One of our previous studies showed that besides a direct support effect, a therapeutic effect on performance was found after several weeks of using the soft-robotic glove as support during ADL. However, several participants reported complaints of increased pain and/or overload, mainly at the beginning of the trial. Clinicians suspect that a (too) high intensity of hand use compared to normal is contributing to this observation. This might be related to more fatigue experienced when using the glove in high-demand tasks, due to a larger movement capacity (faster, further, more repetitions) and can be associated with decreased blood perfusion/lower saturation levels at muscular level and altered muscle activation and movement coordination. The primary objective is to examine the effect of use of the assistive soft-robotic glove during strenuous ADL tasks on the kinematic movement profile, compared to not using the soft-robotic glove. Secondary objectives are to examine whether pain or discomfort is experienced in strenuous activities with the soft-robotic glove as well as the characteristics and locations of such pain/discomfort, and to examine whether use of the glove is associated with increased handgrip strength, larger number of ADL task repetitions, diminished blood perfusion / reduced tissue saturation at the muscle and/or changes in muscle activity. The study is set-up as a cross-sectional intervention study with one measurement session, where participants will perform maximum handgrip strength tests and high-demand ADL-tasks with and without the soft-robotic glove. The aim is to include 20 participants in total, 10 of which will be frail elderly and the other 10 will be neuromuscular patients, all suffering from reduced hand function. All participants will perform each movement task with and without the soft-robotic glove. The soft-robotic glove used in the study is the Carbonhand system (Bioservo Technologies, Sweden). It is a CE-marked medical device and it consists of a glove that supports finger flexion via sewn-in tendons and a control unit housing the actuators that pull on the tendons and the batteries. The grip support is activated by applying very light pressure on sensors in the fingertips of the glove, and de-activated by releasing the pressure on the sensors. After execution of all tasks with and without glove, differences in outcome measures will be compared between glove conditions. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05318638
Study type Interventional
Source Roessingh Research and Development
Contact G. Prange, PhD
Phone +31 88875777
Email g.prange@rrd.nl
Status Recruiting
Phase N/A
Start date October 17, 2022
Completion date December 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT06287502 - Efficacy of Structured Exercise-Nutritional Intervention on Sarcopenia in Patients With Osteoporosis N/A
Recruiting NCT05063279 - RELIEF - Resistance Training for Life N/A
Completed NCT03644030 - Phase Angle, Lean Body Mass Index and Tissue Edema and Immediate Outcome of Cardiac Surgery Patients
Recruiting NCT06143592 - Inspiratory Muscle Training on Balance, Falls and Diaphragm Thickness in the Elderly N/A
Terminated NCT04350762 - Nutritional Supplementation in the Elderly With Weight Loss N/A
Enrolling by invitation NCT05953116 - Managing the Nutritional Needs of Older Filipino With Due Attention to Protein Nutrition and Functional Health Study N/A
Recruiting NCT04028206 - Resistance Exercise or Vibration With HMB for Sarcopenia N/A
Enrolling by invitation NCT03297632 - Improving Muscle Strength, Mass and Physical Function in Older Adults N/A
Completed NCT04015479 - Peanut Protein Supplementation to Augment Muscle Growth and Improve Markers of Muscle Quality and Health in Older Adults N/A
Completed NCT03234920 - Beta-Hydroxy-Beta-Methylbutyrate (HMB) Supplementation After Liver Transplantation N/A
Recruiting NCT03998202 - Myopenia and Mechanisms of Chemotherapy Toxicity in Older Adults With Colorectal Cancer
Recruiting NCT04717869 - Identifying Modifiable PAtient Centered Therapeutics (IMPACT) Frailty
Completed NCT05497687 - Strength-building Lifestyle-integrated Intervention N/A
Completed NCT03119610 - The Physiologic Effects of Intranasal Oxytocin on Sarcopenic Obesity Phase 1/Phase 2
Recruiting NCT05711095 - The Anabolic Properties of Fortified Plant-based Protein in Older People N/A
Recruiting NCT05008770 - Trial in Elderly With Musculoskeletal Problems Due to Underlying Sarcopenia - Faeces to Unravel Gut and Inflammation Translationally
Not yet recruiting NCT05860556 - Sustainable Eating Pattern to Limit Malnutrition in Older Adults
Recruiting NCT04522609 - Electrostimulation of Skeletal Muscles in Patients Listed for a Heart Transplant N/A
Recruiting NCT04545268 - Prehabilitation for Cardiac Surgery in Patients With Reduced Exercise Tolerance N/A
Recruiting NCT03160326 - The QUALITY Vets Project: Muscle Quality and Kidney Disease