To re-investigate the success rate of Ultrasound guided sacroiliac joint steroid injection in depositing the drug inside the joint capsule (confirmed by contrast spread in fluoroscopy) and if there is a difference in clinical outcome between injections done strictly inside the joint and injections done periarticular.


Clinical Trial Description

An IV cannula will be inserted, and basic ASA monitors applied, then the patients will be positioned in prone position. After disinfection of the skin, Ultra sonography will be used to Guide Needle Placement in SIJ (the hypoechoic cleft between the surface of the sacrum and the ilium) under complete a sepsis as the technique previously described in the literature.

A low frequency (2-5 Hz) curvilinear transducer will be used in a sterile cover, the posterior superior iliac spine, lateral borderof sacrum, and ilium will be identified in transverse orientation. Subsequently, the probe will be moved caudally until the superior part of the posterior SIJ is identified. The SIJ will be traced caudally until the distal third of the SIJ is visualized as evident by the flat contour of the iliac crest and the presence of the second sacral foramen on the medial aspect of the sacrum.

After local anesthetic infiltration of skin and subcutaneous tissues using Lidocaine 1%, a 21-gauge spinal needle will be advanced from a medial to lateral direction using an in-plane technique. After reaching the joint, a total volume of 4 ml of injectate will be injected which consists of: 1 ml 40 mg of methylprednisoloneacetate (Depo-Medrol®, Pfizer), 2 ml Lidocaine 2%, 1 ml Iohexol (Omnipaque 300®, GE Healthcare).

Control fluoroscopy

After injection of the drug and withdrawal of the needle, a antero-posterior fluoroscopy image will be obtained and recorded for the injected joint to detect the spread pattern of the contrast and whether its pre-dominantly intra or periarticular. (N.B: Periarticular injection is any injection done near the joint as evidenced by US but on fluoroscopy no contrast is detected inside the joint). Then a sterile patch will be applied to the puncture site and patient discharged to the recovery room for follow-up for 30 minutes before discharge to home.

Measurement tools

- Total number of intraarticular and periarticular drug injections as evidenced by contrast spread in fluoroscopy.

- Patient's pain score rated from 0-10 (Numeric Pain Rating Scale, NRS) before the procedure, 10 minutes after the procedure (in the recovery room), 1 week and 1 month post-procedure.

- Demographic data (including age, sex, BMI, ASA score).

- Limitation of physical functioning as measured by the Oswestry Disability Index (ODI) at 1 month after the procedure .

- Procedure-related variables (time, complications, patient satisfaction. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04314609
Study type Interventional
Source Cairo University
Contact
Status Completed
Phase N/A
Start date October 1, 2019
Completion date June 1, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT03689881 - Value of Tomosynthesis for the Detection of Sacro-iliitis (TOMOS SI) N/A
Recruiting NCT05396495 - Safety and Feasibility of the NeurolyserXR for Sacroiliac Joint Pain N/A
Completed NCT02425631 - CT Follow-Up of the SImmetry Sacroiliac Joint Fusion System N/A
Completed NCT02420041 - Comparing the Effects of Ultrasound Versus Fluoroscopy for Sacroiliac Joint Injections N/A
Enrolling by invitation NCT05916092 - Post-Market Clinical Study on a Modular SI Joint Fusion System
Not yet recruiting NCT06034808 - Frequency of Sacroiliitis in Inflammatory Bowel Disease Patients Using MRI
Not yet recruiting NCT06053255 - Use of the Neurolyser XR for the Treatment of Low Back Pain Related to Sacroiliitis N/A
Withdrawn NCT03992053 - Imaging for SIJ Injection Therapy N/A
Completed NCT03122119 - Effectiveness of Ultrasound Guided Platelet Rich Plasma Injections in the Sacroiliac Joint Phase 4
Enrolling by invitation NCT05203926 - Significance and Outcome of Magnetic Resonance Enterography Revealing Sacroiliitis in Crohn's Disease: A Pilot Study N/A
Recruiting NCT05715463 - Rheumatology-based Adaptive Intervention for Social Determinants and Health Equity N/A
Completed NCT02098694 - Physiotherapy-led Outpatient Clinic for Patients With Spondyloarthritis N/A
Recruiting NCT05276024 - Evaluation of the iFuse Bedrock Technique in Association With Posterior Lumbosacral Fusion With Iliac Fixation.
Completed NCT01673633 - Sacroiliitis in Systemic Sclerosis N/A
Enrolling by invitation NCT05712850 - Clinical Outcome and Fusion Results Using the SiJoin® Transfixing Sacroiliac Fusion Device
Active, not recruiting NCT03631030 - Cooled RF Lesion MRI Characteristics N/A
Completed NCT03834480 - Intraartecular Platelet Rich Plasma for Sacroiliitis N/A