Rotator Cuff Tear Clinical Trial
Official title:
Failure With Continuity and Its Relation to Rotator Cuff Repair Clinical Outcomes
This proposal's objective is to challenge and expand the current definition of rotator cuff healing by investigating tendon retraction - broadly defined as medial translation of the repaired tendon away from the bone with or without a defect - as a common and clinically predictive structural outcome following rotator cuff repair. The investigators' central hypothesis is that failure with continuity is a common yet unrecognized structural phenomenon of rotator cuff healing that is significantly and meaningfully correlated with clinical outcomes. The investigators' approach is to characterize tendon retraction using an array of implanted radio-opaque markers, and investigate its relationship to pre-operative tissue quality (MRI), post-operative repair structural integrity (MRI) and clinical outcomes in a 125-patient prospective cohort study. These patients will complete (1) validated questionnaires and range of motion testing pre-operatively, (2) CT imaging at day of surgery, 3 weeks, 3 and 6 months, and 1, 2 and 5 years post-operatively, (3) MRI at 3 weeks, 3 and 6 months, and 1, 2 and 5 years post-operatively and (4) questionnaires, range of motion and strength testing at 3 and 6 months and 1, 2 and 5 years post-operatively.
Currently, rotator cuff healing is defined as "intact", "attenuated", or "failed" based on the observation (or not) of a recurrent defect (i.e., a "gap") in the tendon using MRI or ultrasound imaging. The investigators' previous work has identified a new outcome, in which there is no detectable defect or "gap" in the repaired tendon, but the repaired tendon has undergone significant retraction. The investigators call this outcome "failure with continuity". Current imaging methods are inadequate to determine the extent to which the repaired rotator cuff tendon has "failed with continuity". The investigators have developed an imaging technique to detect this phenomenon. Specifically, radio-opaque markers are sutured onto the repaired tendon. The distance between the tendon markers and the bone is measured from CT scans taken within 2 weeks of surgery, and compared to the distance measured at 3 and 6 months and 1, 2 and 5 years post-operatively. If the tendon retracts away from the bone during healing, this distance will increase over time. Healing of the tendon will also be monitored in the traditional manner by MRI scans at the same time points. The investigators will investigate the relationship between tendon retraction, MR imaging and clinical outcomes including shoulder strength and patient satisfaction. The investigators expect to show that tendon retraction is common, occurs early post-operatively, with or without repair continuity as assessed by traditional imaging, and significantly correlates with clinical outcomes. The immediate and highly significant consequence of this finding would be a paradigm shift in the investigators' understanding of tendon repair healing, now incorporating the magnitude, timing and location of tendon retraction as well as the continuity of the repaired tissue. This information would yield a more precise understanding of rotator cuff tendon healing, allowing for advances in treatment strategies that improve surgical healing and clinical outcomes and result in more durable rotator cuff repairs over time. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
Completed |
NCT03663036 -
Arthroscopic Superior Capsular Reconstruction With Fascia Lata Autograft - Survivorship of the Autograft Analysis
|
N/A | |
Suspended |
NCT03290196 -
The Effect of EXPAREL® on Postsurgical Pain, and the Use of Narcotics
|
Phase 4 | |
Active, not recruiting |
NCT03091075 -
Oxandrolone Rotator Cuff Trial
|
N/A | |
Completed |
NCT03380533 -
Buprenorphine Transdermal Patches in Arthroscopic Rotator Cuff Repair
|
Phase 2/Phase 3 | |
Completed |
NCT04566939 -
A Long Term Follow-Up of Rotator Cuff Tear Patients Treated With Integrated Complementary and Alternative Medicine
|
||
Completed |
NCT03540030 -
Opioid-Free Shoulder Arthroplasty
|
Phase 4 | |
Completed |
NCT02298023 -
Treatment of Tendon Injury Using Allogenic Adipose-derived Mesenchymal Stem Cells (Rotator Cuff Tear)
|
Phase 2 | |
Completed |
NCT01383239 -
Impact of Postoperative Management on Outcomes and Healing of Rotator Cuff Repairs
|
N/A | |
Completed |
NCT01459536 -
Assessment of Muscle Function and Size in Older Adults With Rotator Cuff Tear
|
N/A | |
Completed |
NCT02850211 -
A Selective COX-2 Inhibitor Provides Pain Control But Hinders Healing Following Arthroscopic Rotator Cuff Repair
|
Phase 4 | |
Completed |
NCT01170312 -
Arthroscopic Surgery and Platelet Rich Plasma In Rotator Cuff Tear Evaluation
|
N/A | |
Terminated |
NCT00936559 -
Study Evaluating Safety Of BMP-655/ACS As An Adjuvant Therapy For Rotator Cuff Repair
|
Phase 1 | |
Completed |
NCT01204606 -
Arthroscopic Rotator Cuff Repair With Multimodal Analgesia(MMA)
|
N/A | |
Completed |
NCT00852657 -
Comparison of Tendon Repair and Physiotherapy in the Treatment of Small and Medium-sized Tears of the Rotator Cuff
|
N/A | |
Active, not recruiting |
NCT00182299 -
An RCT to Compare the Outcomes of Patients With Large Rotator Cuff Repair That Undergo Repair With or Without SIS
|
Phase 4 | |
Recruiting |
NCT06120998 -
Quality of Life After Arthroscopic Rotator Cuff Repair
|
||
Completed |
NCT05897866 -
Sayed Issa's Hybrid Shoulder Arthroscopic-Open Surgical Management (HSSM)
|
N/A | |
Completed |
NCT02644564 -
Early Clinical Examination and Ultrasonography Screening of Acute Soft Tissue Shoulder Injuries
|
N/A | |
Withdrawn |
NCT03739749 -
Arthroscopic Superior Capsular Reconstruction - Study of Different Types of Grafts
|
N/A |