Risk of Heat Stress Clinical Trial
Official title:
Impact of Pre-cooling in Adolescent Athletes While Playing Tennis in Hot Conditions
Verified date | December 2019 |
Source | University of Thessaly |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Many tennis tournaments are played outdoors in hot and humid conditions, which poses a significant challenge particularly for children athletes. The purpose of this investigation is to examine if a precooling method can reduce thermal strain and consequently improve the performance of adolescent tennis athletes while exercising in hot conditions.
Status | Completed |
Enrollment | 8 |
Est. completion date | September 30, 2018 |
Est. primary completion date | September 30, 2018 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 14 Years to 17 Years |
Eligibility |
Inclusion Criteria: - Healthy adolescent athletes Exclusion Criteria: - Diagnosed chronic medical condition; - Symptoms of acute illness; - Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status. |
Country | Name | City | State |
---|---|---|---|
Greece | FAME Lab, Department of Exercise Science, University of Thessaly | Tríkala | Thessaly |
Lead Sponsor | Collaborator |
---|---|
Petros Dinas |
Greece,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Heart rate | Heart rate data were continuously monitored using a Polar Team system (Polar® Team 2, Polar Electro Oy, Kempele, Finland | Up to 4 hours, during a one complete tennis match | |
Primary | Core temperature | Visceral temperature was continuously recorded throughout the match using telemetric pills (BodyCap, Caen, France) | Up to 4 hours, during a one complete tennis match | |
Primary | Skin temperature | Skin temperature was continuously recorded throughout the match using iBUTTON sensors (type DS1921 H, Maxim/Dallas Semiconductor Corp., USA) | Up to 4 hours, during a one complete tennis match | |
Primary | Change from baseline thermal comfort at after each set | Thermal comfort was assessed via the thermal comfort scale (1 = comfortable; 5 = extremely uncomfortable). | Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match | |
Primary | Change from baseline thermal sensation at after each set | Thermal sensation was assessed via the thermal sensation scale (-3 = cold; +3 = hot) | Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match | |
Primary | Change from baseline rating of perceived exertion at after each set | We used the Borg 20th Scale (6 = no exertion at all; 20 = maximal exertion) | Change from baseline up to 1 hour after each set and up to 4 hours at the end of the match | |
Primary | Change from baseline urine specific gravity (hydration status) at the end of each match | Urine samples was obtained to evaluate the urine specific gravity. Urine specific gravity (single assessmentno units) was assessed using a refractometer (PAL-10S, ATAGO CO., LTD., Fukaya, Saitama Prefecture, Japan). Urine color was assessed using a urine color scale | Change from baseline up to 4 hours at the end of the tennis match | |
Primary | Match - play characteristics (i.e., performance) | They were recorded by analyzing the video footage from the match. The quantitative performance indices assessed were: games and points won in each set and normalized to the number of games and points recorded in each set, respectively. Unforced errors, first and second serve accuracy, aces, shots per rally and direction changes in each point calculated. Point's duration, between point-duration as well the effective point time calculated. The effective point time starting with the ball toss of the serve and ending when the ball passed the player or bounced twice on court. In case of double fault, starting time recorded from the beginning of the second serve. | Up to 4 hours, during a one complete tennis match | |
Primary | Air temperature | It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's | Up to 4 hours, during a one complete tennis match | |
Primary | Relative humidity | It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines | Up to 4 hours, during a one complete tennis match | |
Primary | Wind speed | It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines | Up to 4 hours, during a one complete tennis match | |
Primary | Solar radiation | It was measured continuously using a portable weather station (Kestrel 5500FW Fire Weather Meter Pro, USA) placed 1 meter above the ground according to the manufacturer's guidelines. Solar radiation is measured directly by the device of portable weather station. | Up to 4 hours, during a one complete tennis match |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04241900 -
Effect of Aging and Aerobic Fitness Level on Heat Dissipation
|
N/A | |
Completed |
NCT04160728 -
Occupational Heat Stress on Workers' Productivity
|
N/A |