Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT03025568
Other study ID # 1989
Secondary ID
Status Not yet recruiting
Phase N/A
First received January 12, 2017
Last updated January 17, 2017
Start date March 2017
Est. completion date October 2017

Study information

Verified date January 2017
Source Cairo University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Evaluation of the retention of upper removable partial denture constructed from two different flexible thermoplastic materials.(BRE-FLEX and PEEK).


Description:

The assessor is responsible for all clinical procedure that will be conducted in this study during all the visits:

Panoramic radiograph and periapical radiographs will be made on the prospected abutment teeth to evaluate the crown-root ratio, the apical condition of the abutment and their alveolar bone support.

The preliminary impression will be performed with irreversible hydro-colloid impression material (alginate), The impressions will be poured with type IV dental stone to obtain diagnostic casts. Maxillary Face-bow will be recorded. The diagnostic casts will be mounted on semi adjustable articulator in centric occluding relation to evaluate the interarch distance and occlusal plane.

Special trays will be constructed and Mouth preparation will be performed by preparing guiding planes and rests seats will be prepared opposing to the edentulous area.

Final impression will be taken by elastomeric impression material. The impression will be poured into type IV dental stone in order to obtain master cast. The master cast will be surveyed. The proposed design will be as follows: metal framework base saddle for edentulous areas on both sides connected with palatal strap. Aker's clasp on all abutments with buccal retention. The denture base will be tried in with acrylic teeth in patient's mouth. After that, the denture base of the partial denture will be processed incorporation with the metal framework into the two different materials to be evaluated. The first group will receive the partial denture in which the metal framework incorporated with the denture base fabricated from PEEK material. The second group will receive the partial denture in which the metal framework incorporated with the denture base material fabricated from BRE-FLEX


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 17
Est. completion date October 2017
Est. primary completion date August 2017
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 45 Years to 55 Years
Eligibility Inclusion Criteria:

- All patients must have Kennedy class III modification I upper partially edentulous ridges.

- The remaining teeth have good periodontal condition, with no signs of attrition or gingival recession.

- Male or female patient with age range (45-55) and in good medical condition

- All patients have skeletal Angle's class I maxillo-mandibular relationship and have sufficient interarch distance.

- Free from any systemic or neuromuscular disorder that might affect chewing efficiency of masticatory muscles.

- Free from any tempro-mandibular joint disorder.

- The patients have good oral hygiene and low caries index.

Exclusion Criteria:

- Patients having abnormal habits as bruxism or clenching

- Patients having hormonal disorders as diabetes, thyroid or parathyroid hormonal diseases were not included.

- Teeth with compromised bone support.

- Patient with xerostomia or excessive salivation.

- Patient with abnormal tongue behavior and/or size.

Study Design


Related Conditions & MeSH terms


Intervention

Other:
PEEK
PEEK (poly-ether-ether-ketone) has been successfully used over the last years in the medical ?eld, and orthopedics, speci?cally. which presents high biocompatibility, good mechanical properties, high temperature resistance, and chemical stability due to a 4 GPa modulus of elasticity, it is as elastic as bone and can reduce stresses transferred to the abutment teeth. Additional advantages of this polymer material are elimination of allergic reactions and metallic taste, high polishing qualities, low plaque af?nity, and good wear resistance, it has only recently been used in dentistry.
Bre.flex
In the recent time thermoplastic materials (breflex) become quite popular in clinical practice such as nylon and acetal resins. since the 1950, polyamide resin (nylons) provide improved esthetics and reduction of rotational forces on the abutment teeth due to their low elastic modulus.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Cairo University

Outcome

Type Measure Description Time frame Safety issue
Primary Evaluation of Retention of removable partial denture constructed from PEEK and Bre-flex The first week, at the time of insertion measuring Retention immediately after partial denture insertion,The third week measuring Retention of the partial denture, The fourth week measuring Retention of the partial denture.
retention is measured by digital force gauge device.
One month
See also
  Status Clinical Trial Phase
Recruiting NCT05557136 - Effectiveness of PEEK Fixed Retainer N/A
Completed NCT04968041 - KNA Proof-of-Concept N/A
Recruiting NCT02436811 - Oral Health Literacy and Oral Education N/A
Completed NCT03070444 - Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment N/A
Not yet recruiting NCT03127033 - Comparison Between Acrylic and Soft Liner Telescopic Overdentures Regarding Patient Satisfaction N/A
Not yet recruiting NCT05670899 - Retention of CAD Metallic and Poly Ether Ether Ketone (PEEK) Frameworks N/A
Completed NCT03224481 - Evaluation of Tailored Electronic Reminders on Compliance With Removable Orthodontic Retention N/A
Completed NCT05014308 - Effect of Piezoelectric Alveolar Decortication on Post-Orthodontic Lower Incisors Stability: A Randomized Clinical Trial N/A
Completed NCT05749991 - Efficacy and Retention of Sealants Placement Using Two Isolation Systems N/A
Completed NCT02618330 - The Clinical Evaluation of Two Different Film Thicknesses of Clear Overlay Retainer. N/A
Completed NCT02214875 - Lafiyan Jikin Mata "Excellent Health for Mothers" N/A
Completed NCT02716558 - A Clinical Trial to Assess the Retention and Caries Preventive Effects of Moisture Tolerant Resin Sealant and ART Sealants Phase 3
Completed NCT01951092 - mHealth Intervention Supporting HIV Treatment Adherence and Retention N/A