Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT06053502
Other study ID # KPTVSPFJUAugust2023
Secondary ID
Status Completed
Phase
First received
Last updated
Start date January 2, 2023
Est. completion date August 26, 2023

Study information

Verified date September 2023
Source University of South Bohemia
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The purpose of this study was to compare breathing pattern and involvement of individual breathing compartments (IBC) with and without filtering facepiece respirator (FFR) during rest and exercise.


Description:

The study involved 21 students majoring in physical education and sports. All subjects were physically active, engaging in approximately 260 minutes of physical activity per week, and they possessed a high level of fitness. Inclusion criteria required participants to be free from injury, capable of providing written consent, and within the age range of 19 to 26 years. Exclusion criteria included individuals who smoked or had chronic pulmonary or cardiac diseases. This research received approval from the Ethics Committee at the Faculty of Education, University of South Bohemia, Reference Number: 002/2018. All procedures conducted within the study adhered to the ethical standards outlined by the Institutional Research Committee and the principles of the Helsinki Declaration. Protocol: Participants were instructed to visit the laboratory on two occasions to complete two separate tests during each session, specifically the Opto-electronic plethysmography (OEP) test during resting in a standing position and the OEP test during a Graded Exercise Test (GXT). The time interval between the testing days was three days. Participants were randomly assigned to two groups using randomizer.org. The first group performed three tests while wearing a Face-Fit Respirator (FFR), while the second group performed the tests without the mask. During the second visit, participants switched to the opposite condition. The N95 respirator was employed in this study as the gold standard for protection against aerosol transmission, particularly during the COVID-19 pandemic. A new mask was used for each test. In the Standing Test (STD), participants were instructed to maintain a stationary standing position and engage in spontaneous, quiet breathing without speaking or altering their posture while OEP data was collected. The first two minutes were designated as an adaptation period, followed by data collection for an additional three minutes. In the context of the Graded Exercise Test (GXT), OEP data was collected during the final minute of each three-minute stage. Opto-Electronic Plethysmography: The analysis of breathing patterns and volumes of chest wall compartments was conducted using opto-electronic plethysmography (BTS Bioengineering, Milan, Italy). This device comprises eight cameras, with five positioned anteriorly and three posteriorly relative to the participant. Additionally, 89 reflective markers were affixed to the participant's chest, abdomen, and back to track movements of the trunk. This technique has previously demonstrated validity in both resting and maximal exercise conditions. The contributions of each breathing compartment (VRCp - pulmonary rib cage, VRCa - abdominal rib cage, VAb - abdomen) were determined by calculating the difference between end-inspiratory and end-expiratory volumes. The specific methodology for calculating chest wall kinematics using OEP has been detailed in prior research. Graded Exercise Tests: To complete this study, participants were required to undergo two maximal graded exercise tests (GXT) on separate days, one with the use of a Face-Fit Respirator (FFR) and one without. After three minutes of warm-up walking (2.7 km/h, 10% incline), participants performed the Bruce Protocol until exhaustion. The Bruce Protocol was conducted on a treadmill (Lode Valiant 2 Sport, Lode B.V., Groningen, Netherlands). All tests were conducted at the same time of day to mitigate the influence of circadian rhythms. Immediately following the completion of the test, participants provided ratings on the Modified Borg Dyspnea Scale, which ranges from 0 to 10, to assess breathlessness.


Recruitment information / eligibility

Status Completed
Enrollment 21
Est. completion date August 26, 2023
Est. primary completion date March 25, 2023
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 19 Years to 26 Years
Eligibility Inclusion Criteria: - physically active (~260 min/week) possessing high fitness level, - free from injury, - able to give full written consent, - meet age criteria 19-26 years. Exclusion Criteria: - smokers, - chronic pulmonary disease, - cardiac disease.

Study Design


Intervention

Other:
filtering facepiece respirator
Graded exercise test with filtering facepiece respirator

Locations

Country Name City State
Czechia University of South Bohemia Ceské Budejovice

Sponsors (1)

Lead Sponsor Collaborator
University of South Bohemia

Country where clinical trial is conducted

Czechia, 

References & Publications (6)

Aliabadi M, Aghamiri ZS, Farhadian M, Shafiee Motlagh M, Hamidi Nahrani M. The Influence of Face Masks on Verbal Communication in Persian in the Presence of Background Noise in Healthcare Staff. Acoust Aust. 2022 Jan 26;50(1):1-11. doi: 10.1007/s40857-021-00260-3. Online ahead of print. — View Citation

Aliverti A, Rodger K, Dellaca RL, Stevenson N, Lo Mauro A, Pedotti A, Calverley PM. Effect of salbutamol on lung function and chest wall volumes at rest and during exercise in COPD. Thorax. 2005 Nov;60(11):916-24. doi: 10.1136/thx.2004.037937. Epub 2005 Jun 30. — View Citation

Au SCL. The model of N95 face mask used and hypercapnia proof upon choroidal thickness measurement. Photodiagnosis Photodyn Ther. 2021 Sep;35:102399. doi: 10.1016/j.pdpdt.2021.102399. Epub 2021 Jun 11. No abstract available. — View Citation

Redlinger RE Jr, Kelly RE, Nuss D, Goretsky M, Kuhn MA, Sullivan K, Wootton AE, Ebel A, Obermeyer RJ. Regional chest wall motion dysfunction in patients with pectus excavatum demonstrated via optoelectronic plethysmography. J Pediatr Surg. 2011 Jun;46(6):1172-6. doi: 10.1016/j.jpedsurg.2011.03.047. — View Citation

Vogiatzis I, Aliverti A, Golemati S, Georgiadou O, Lomauro A, Kosmas E, Kastanakis E, Roussos C. Respiratory kinematics by optoelectronic plethysmography during exercise in men and women. Eur J Appl Physiol. 2005 Mar;93(5-6):581-7. doi: 10.1007/s00421-004-1249-4. Epub 2004 Dec 1. — View Citation

Wilson RC, Jones PW. A comparison of the visual analogue scale and modified Borg scale for the measurement of dyspnoea during exercise. Clin Sci (Lond). 1989 Mar;76(3):277-82. doi: 10.1042/cs0760277. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Inspiratory time Inspiratory time in every phase of the GXT will be presented as a mean and standard deviation, along with the mean difference and a 95% confidence interval of the difference. Inspiratory time will be measured using opto-electronic plethysmography, with units in [s], and the outcomes will be compared using a repeated-measures ANOVA with intra-subject comparisons. up to 12 weeks
Primary Expiratory time Expiratory time in every phase of the GXT will be presented as a mean and standard deviation, along with the mean difference and a 95% confidence interval of the difference. Expiratory time will be measured using opto-electronic plethysmography, with units in [s], and the outcomes will be compared using a repeated-measures ANOVA with intra-subject comparisons. up to 12 weeks
Primary Chest wall compartments The individual contribution of chest wall compartments in every phase of the GXT will be presented as a mean and standard deviation, along with the mean difference and a 95% confidence interval for the difference. Chest wall compartments will be measured using opto-electronic plethysmography, with units in [%VT - Tidal volume], and the outcomes will be compared using a repeated-measures ANOVA with intra-subject comparisons. up to 12 weeks
Primary Breathing frequency Breathing frequency in each phase of the GXT will be presented as a mean and standard deviation, along with the mean difference and a 95% confidence interval for the difference. Breathing frequency will be measured using opto-electronic plethysmography, with units in [bpm], and the outcomes will be compared using a repeated-measures ANOVA with intra-subject comparisons. up to 12 weeks
See also
  Status Clinical Trial Phase
Completed NCT03946137 - Chest Therapy and Postural Education in Children With Cerebral Palsy N/A
Completed NCT06089226 - Parameters Related to Physical Activity Level in SCI
Completed NCT03931902 - The Comparison of Laryngeal Mask Airway and Endotracheal Tube in General Anesthesia for Premature Neonates N/A
Completed NCT03105739 - Timing of Withdrawal of the Laryngeal Mask Airway (LMA) in Children N/A
Recruiting NCT04100512 - Oscillating Positive Expiratory Pressure (OPEP) Therapy in Trauma Patients With Multiple Rib Fractures N/A
Enrolling by invitation NCT06360666 - Clinical Outcomes in Adult Patients Undergoing Laparoscopic Surgery Under Neuraxial Anesthesia
Recruiting NCT06149494 - RCT of Vapendavir in Patients With COPD and Human Rhinovirus/Enterovirus Upper Respiratory Infection Phase 2
Completed NCT03056885 - Inflammatory Local Response During OLV: Protective vs Conventional Ventilation Strategy N/A
Recruiting NCT05136781 - DEXAMETHASONE for Non-urgent Thoracic Surgery
Terminated NCT03665259 - Lower Inspiratory Oxygen Fraction for Preoxygenation N/A
Not yet recruiting NCT03255356 - Ventilation in Cardiac Surgery N/A
Terminated NCT03571646 - LIFEGUARD Study - Continuous Respiratory Monitoring on the General Ward N/A
Not yet recruiting NCT05363098 - The Cerebral-Respiratory Interaction During Spontaneous Breathing Ventilation in Neurosurgical Patients (CeRes-SB)
Recruiting NCT03969147 - Investigation of a Novel Oropharyngeal Airway: The ManMaxAirway N/A
Recruiting NCT06412081 - Lung Ultrasound for Physiotherapy in Hospitalized Patients With Respiratory Complications
Completed NCT03218215 - Monitoring Mechanical Assisted Cough N/A
Completed NCT03102619 - Wireless Assessment of Respiratory and Circulatory Distress; A Pilot Study N/A
Recruiting NCT05804175 - Advanced Prediction of Respiratory Depression Episode With the Linshom Continuous Predictive Respiratory Sensor
Recruiting NCT06301126 - Virtual Reality on Pulmonary Function After Upper Abdominal Surgeries N/A
Not yet recruiting NCT06443515 - Respiratory Trends During Blood Transfusions in Newborns. N/A