Renal Failure Clinical Trial
Official title:
Myoglobin Reduction by High Cut-off (HCO) Continuous Veno- Venous Hemodialysis (CVVHD) in Patients With Rhabdomyolysis and an Increased Risk for Acute Kidney Injury
A high cut-off dialyzer (septeX) is tested for the removal of myoglobin which is not efficiently removed by standard high flux dialysis membranes. Hypothesis: The high cut-off dialyzer (septeX) can remove 2-fold more efficiently myoglobin from the circulation of Rhabdomyolysis patients as by conventional treatment with standard high flux dialyzer.
Excess myoglobin in the circulation is a causative pathogenetic factor of rhabdomyolysis
associated with acute kidney injury (AKI). The rapid elimination of myoglobin by standard
dialysis membranes is limited to its molecular weight of 17.8kDa, although some removal can
be achieved when a convective therapy is applied.
Significant clearance for myoglobin has been reported for high flux membranes from < 8
mL/min (5) up to 22 mL/h (CVVH) (10) and for high cut-off (HCO) membranes a mean clearance
rate of 36.2 mL/min in HD mode (7) and 39.2 mL/h in CVVH mode (5). The use of high cut-off
(HCO) continuous veno- venous hemodialysis (CVVHD) may constitute a novel therapeutic
strategy for effectively reduction of myoglobin in the patient's serum to ameliorate the
course of AKI.
Previously, a case study of the removal of myoglobin by HCO-CVVH in one single patient with
severe rhabdomyolysis was published.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02763410 -
Impact of the Composition of Packed Red Blood Cell Supernatant on Renal Dysfunction and Posttransfusion Immunomodulation
|
||
Active, not recruiting |
NCT03183245 -
Comparison of the Human Acellular Vessel (HAV) With Fistulas as Conduits for Hemodialysis
|
Phase 3 | |
Completed |
NCT04084301 -
Impact of Cardiopulmonary Bypass Flow on Renal Oxygenation, Blood Flow and Tubular Injury
|
N/A | |
Completed |
NCT03292029 -
Pilot Medical Evaluation of the T50 Test
|
N/A | |
Suspended |
NCT04589065 -
SCD for CRS in Congestive Heart Failure (CHF) (No Left Ventricular Assist Device)
|
N/A | |
Completed |
NCT03806998 -
Effects of a Ketoacid Supplementation in Patients With Stage III to IV Renal Failure
|
Phase 3 | |
Active, not recruiting |
NCT03672110 -
Slow and Low Start of a Tacrolimus Once Daily Immunosuppressive Regimen
|
Phase 3 | |
Completed |
NCT02325726 -
RRI Compared With NephroCheckTM to Predict Acute Renal Failure After Cardiac Surgery.
|
N/A | |
Completed |
NCT02116270 -
Accelerated Immunosenescence and Chronic Kidney Disease
|
N/A | |
Completed |
NCT01859273 -
Adherence Enhancement for Renal Transplant Patients
|
N/A | |
Completed |
NCT01388270 -
Effect of a Pre Heparin Coated Dialysis Filter on Coagulation During Hemodialysis
|
Phase 4 | |
Completed |
NCT00966615 -
The Effect of Neutral Peritoneal Dialysis (PD) Solution With Minimal Glucose-Degradation-Product (GDP) on Fluid Status and Body Composition
|
Phase 4 | |
Completed |
NCT01187953 -
Double-Blind,Double-Dummy,Efficacy/Safety,LCP-Tacroâ„¢ Vs Prograf®,Prevention Rejection,De Novo Adult Kidney Tx
|
Phase 3 | |
Completed |
NCT01476995 -
Prognostic Indicators as Provided by the EPIC ClearView
|
N/A | |
Completed |
NCT01008631 -
The Pharmacologic Profile of Sodium Thiosulfate in Renal Failure and Healthy Volunteers
|
N/A | |
Completed |
NCT00765661 -
Pharmacokinetics of LCP-Tacro(TM) Once Daily And Prograf® Twice A Day in Adult De Novo Kidney Transplant Patients
|
Phase 2 | |
Completed |
NCT00737672 -
GORE VIABAHN Endoprosthesis Versus Percutaneous Transluminal Angioplasty (PTA) to Revise AV Grafts in Hemodialysis
|
Phase 3 | |
Completed |
NCT00808691 -
Microcirculation and Oxidative Stress in Critical Ill Patients in Surgical Intensive Care Unit
|
N/A | |
Recruiting |
NCT00470769 -
The Efficacy of Color-Doppler Ultrasonography to Assess the Renal Blood Flow With the Estimation of GFR
|
N/A | |
Terminated |
NCT00338455 -
Natrecor (Nesiritide) in Transplant-Eligible Management of Congestive Heart Failure-TMAC
|
Phase 2 |