Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05113979
Other study ID # CIIPCL-018
Secondary ID
Status Completed
Phase
First received
Last updated
Start date March 9, 2020
Est. completion date September 9, 2022

Study information

Verified date April 2024
Source OnPoint Vision Inc
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

To determine if the intraocular pseudophakic contact lens (IOPCL), referred to as the AccuraSee, corrects residual refractive errors after cataract surgery using a plus powered lens in subjects with ocular pathology previously implanted with a Bausch and Lomb LI61AO or LI61SE monofocal posterior chamber intraocular lens (PCIOL) and to confirm its positional stability and adherence relative to the PCIOL.


Description:

This will be a 12-month study in which a maximum of 10 pseudophakic patients from three clinical sites will be enrolled. All enrolled subjects will receive an AccuraSee IOPCL with +3.0D add to correct residual refractive errors identified after cataract surgery. The primary objective of this study is to determine the stability of the AccuraSee IOPCL to successfully adhere to a pseudophakic intraocular lens (PCIOL) without rotation or slippage. The secondary objective of this study is to determine if the AccuraSee IOPCL can successfully correct refractive errors in subjects previously implanted with a Bausch and Lomb LI61AO and LI61SE monofocal intraocular lens.


Recruitment information / eligibility

Status Completed
Enrollment 10
Est. completion date September 9, 2022
Est. primary completion date September 9, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 22 Years and older
Eligibility Inclusion Criteria: - Subjects who have already had cataract surgery with a Bausch and Lomb monofocal intraocular lens model LI61AO (with lens power from 18.0 diopters (D) to 23.0 D) or model LI61SE monofocal intraocular lens (with a lens power between from18.0 D and 23.0 D), clearly evidenced by photographic documentation with one of the following: (1) patient medical record, (2) clinic chart with labeling attached, (3) surgical record with labeling attached, or (4) patient identification card with make, model, power, and serial number. - Able to comprehend and sign a statement of informed consent. - Willing and able to complete all required postoperative visits. - Subjects who's baseline manifest refraction spherical equivalent (MRSE) is between -0.5D and +3.0D - Best corrected visual acuity 20/80 or worse. - Subjects with =1.0D 5D of refractive corneal cylinder - Subjects willing to abstain from pursuing any other surgical vision-correcting procedures for the duration of the study. - Subject must be at least 22 years or older. Exclusion Criteria: - Subjects who have already had cataract surgery with a Toric or multifocal Intraocular Lens. - Subjects who have already had cataract surgery with a Bausch and Lomb monofocal intraocular lens model LI61AO (with a lens power below 18.0 D and greater than 23.0 D) or model LI61SE (with a lens power below 18.0 D and greater than 22.5 D). - Subjects who were treated with an IOL off-label. - Subjects who have MRSE of less than 1.0 Diopter (+1.0 to -1.0 D) and more than +3.0D - Subjects who have more than 1.5D of refractive corneal cylinder - Subjects whose continuous curvilinear capsulorhexis was less than 5mm or more than 6.0 mm in size at the time of IOL surgery. - Subjects who had cataract surgery less than 6 months from the planned date of the IOPCL surgery. - Subjects with anterior capsule fibrosis and phimosis that in the opinion of the investigator may confound the outcome or increase the risk to the subject. - Acute, chronic or uncontrolled systemic or ocular disease that in the opinion of the investigator would increase the operative risk or confound the outcome(s) of the study. - Any corneal abnormality, other than regular corneal astigmatism that in the opinion of the investigator would confound the outcome(s) of the study. - Clinically severe corneal dystrophy (e.g., epithelial, stromal, or endothelial dystrophy). - Microphthalmos. - Previous retinal detachment. - Recurrent severe anterior or posterior segment inflammation of unknown etiology. - Iris neovascularization. - Uncontrolled glaucoma. - Aniridia. - Optic nerve atrophy. - Damaged or incomplete zonules. - Known history of pseudoexfoliation. - Medications that, in the opinion of the investigator, may confound the outcome or increase the risk to the subject (tamsulosin hydrochloride (Flomax)) or other medications with similar side effects (floppy iris syndrome).

Study Design


Related Conditions & MeSH terms


Intervention

Device:
AccuraSee IOPCL with +3.0D add
The IOPCL (intraocular pseudophakic contact lens) consists of a 4.5mm diameter optic. All subjects will receive a +3.0 power regardless of diopter power based on IOL Master. This IOPCL will be coupled to a Bausch and Lomb Model LI61SE or LI61AO intraocular lens to correct residual refractive errors after cataract surgery.

Locations

Country Name City State
United States Chu Vision Institute Bloomington Minnesota

Sponsors (1)

Lead Sponsor Collaborator
OnPoint Vision Inc

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Other Change in UCDVA From Baseline Change in Uncorrected Distance Visual Acuity (UCDVA) from Baseline measured in lines (5 letters) on ETDRS (Early Treatment Diabetic Retinopathy Study) Baseline and 330-420 days
Primary Subjects With Stable Manifest Refraction Spherical Equivalent (MRSE) Proportion of subjects (= 50%) able to achieve MRSE stability within ±0.5D within two consecutive postoperative visits at 1 month or later visits. Assessed all postoperative consecutive visit pairings beginning with 1 month visit (1 month to 4 months; 4 months to 1 year); reported for "Postoperative period between 1 month and 1 year"
Primary Subjects With Successful Delivery of AccuraSee IOPCL Successful delivery of the AccuraSee IOPCL is defined as: 1) No capsular tear; 2) Visualized centration between the PCIOL and the IOPCL; 3) No visible damage to either the PCIOL or the IOPCL; and 4) Uniform leaflet coverage of all IOPCL haptic tabs 7-14 days visit
Primary Long Term Adherence and Positional Stability: Number of Participants With Greater or Less Than +/- 10 Microns Change in Gap Between the Pseudophakic Intraocular Lens and AccuraSee Intraocular Pseudophakic Contact Lens Safety Endpoint: Minimal change in uniformity of the gap between the pseudophakic intraocular lens (PCIOL) and AccuraSee intraocular pseudophakic contact lens (IOPCL), between 30-60 days and 120-180 days, as determined by ultrasound biomicroscopy (UBM) measurements. Minimal change is defined as +/- 10 microns. Assessed at 30-60 days visit and 120-180 days visit, 120-180 days visit reported
See also
  Status Clinical Trial Phase
Completed NCT04532099 - Clinical Comparison of Two Daily Wear Frequent Replacement Silicone Hydrogel Soft Contact Lenses N/A
Completed NCT05039112 - Clinical Comparison of 2 Daily Disposable Toric Soft Contact Lenses N/A
Completed NCT03670303 - Trial of an Educational Intervention to Promote Spectacle Use Among Secondary School Children in Islamabad, Pakistan N/A
Completed NCT02255474 - Bifocal Lenses In Nearsighted Kids N/A
Not yet recruiting NCT03222661 - Direct Comparison of SVOne Obtained Refraction to Subjective Manifest Refraction N/A
Completed NCT04055519 - Clinical Performance Assessment of a Daily Wear Monthly Replacement Soft Silicone Hydrogel Contact Lens N/A
Recruiting NCT05049070 - Study to Evaluate the Reliability, Validity and Safety of Subjective Mobile Refraction N/A
Completed NCT04527978 - Clinical Comparison of 2 Daily Disposable Contact Lenses - Pilot Study 1 N/A
Completed NCT01430247 - Vision Screening for the Detection of Amblyopia N/A
Recruiting NCT06077682 - Cycloplegic Refraction in Pediatric Patients With Esotropia Phase 4
Not yet recruiting NCT04077086 - Correcting Myopia Among Secondary School Children to Increase Academic High School Attendance Rates in Rural Communities N/A
Completed NCT04528017 - Clinical Comparison of 2 Daily Disposable Contact Lenses - Pilot Study 2 N/A
Withdrawn NCT04352868 - Customizing Myopia Control With Multifocal Toric Contact Lens N/A
Recruiting NCT04338880 - Academic Performance and Refractive Error
Recruiting NCT04545073 - Outcomes of a Trifocal IOL in Post-refractive Patients
Enrolling by invitation NCT05992675 - Air Optix® Night and Day® Aqua Continuous Wear
Enrolling by invitation NCT05976750 - Air Optix® Night and Day® Aqua Daily Wear
Recruiting NCT04693247 - Handheld Device Compared With a Standard Eye Care Diagnostic Device in Measuring Ophthalmic Refraction N/A
Recruiting NCT06065631 - Seeing to Learn in Sierra Leone N/A
Not yet recruiting NCT05550740 - Repeated Low-Level Red-Light Therapy for Shortening Axial Length N/A