Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT01882465
Other study ID # CR-5360
Secondary ID
Status Terminated
Phase N/A
First received
Last updated
Start date August 2013
Est. completion date August 2013

Study information

Verified date November 2016
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Limbal ring contact lenses enhance the look of the eye by adding pigmentation in a ring pattern to the contact lens. The purpose of this investigation is to determine if corneal staining increase is dependent upon the lens pigment location.


Recruitment information / eligibility

Status Terminated
Enrollment 35
Est. completion date August 2013
Est. primary completion date August 2013
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 35 Years
Eligibility Inclusion Criteria:

1. The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form.

2. Fluency in English and ability to read and understand written English.

3. The subject must be able and willing to adhere to the instructions set forth in this clinical protocol.

4. The subject must be between 18 and 35 years of age.

5. The subject must be an adapted (minimum of 4 week history of daily wear prior to the baseline study visit) soft contact lens wearer in both eyes.

6. The subject must be East or Southeast Asia descent, e.g. ethnic Chinese, Japanese, Korean, Malay, Vietnamese, Indonesian, Filipino, etc. by self-report.

7. The subject must come in with a current (no more than 12 month old) spectacle or contact lens prescription as indicated. (NB: Emmetropic subjects who wear contact lenses for enhancement purposes only will also require a current contact lens prescription).

8. The subject's vertex corrected spherical equivalent distance refraction must be in the range of PLANO to -6.00 Diopter (D) in each eye.

9. The subject must have best corrected visual acuity on +0.24 logMAR (equivalent to 20/30 (-2)) or better in each eye.

10. The subject must own a wearable pair of spectacles (as indicated by current prescription) and wear them to all visits including the screening visit as required for vision correction. They must be willing to wear their spectacles during the 24 hour washout period leading up to each treatment visit (NB: Emmetropic subjects who do not own spectacles must agree to no lens wear on all visit days including the screening visit).

11. The subject must have normal eye (i.e., no ocular medications or infections of any type).

Exclusion Criteria:

1. Are currently pregnant or lactating, determined by self-report (subjects who become pregnant during the study will be discontinued).

2. Have any ocular or systemic allergies or diseases that may interfere with contact lens wear.

3. Have any systemic disease, autoimmune disease, or use of medication, which may interfere with contact lens wear. This may include, but may not be limited to diabetes, hyperthyroidism, recurrent herpes simplex/zoster, Sjogren's syndromes, xerophthalmia, acne rosacea, Stevens-Johnson syndromes.

4. Use any topical medication such as eye drops or ointment.

5. Have entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, or aphakia.

6. Had any previous, or have planned, ocular or intraocular surgery (e.g., cataract surgery, radial keratotomy, photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK).

7. Have any grade 3.0 or greater slit lamp findings (e.g., edema, corneal neovascularization, corneal staining, tarsal abnormalities, conjunctival injection) on the Efron classification scale or any other ocular abnormality that may contraindicate contact lens wear.

8. Have any known hypersensitivity or allergic reaction to contact lenses (as assessed by ocular history).

9. Have any ocular infection.

10. Have any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear.

11. Have participated in any contact lens or lens care product clinical trial within 14 days prior to study enrollment.

12. Have any infectious disease (e.g., hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g. HIV), by self-report.

13. Currently wear their contact lenes on an extended wear basis.

14. Is an employee of the investigational clinic (e.g., Investigator, Coordinator, Technician).

15. Currently wears toric or multifocal contact lenses. If the subject wears soft contact lenses for monovision, they must be willing to wear distance only correction in both eyes for the study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
etafilcon A
Lenses to be worn in a daily wear modality, and disposed of at the end of each follow-up visit.
2-HEMA, EGDMA Non-ionic
Lenses to be worn in a daily wear modality, and disposed of at the end of each follow-up visit.
hefilcon A
Lenses to be worn in a daily wear modality, and disposed of at the end of each follow-up visit.

Locations

Country Name City State
Hong Kong Hong Kong Polytechnic University Hong Hom Kowloon

Sponsors (1)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc.

Country where clinical trial is conducted

Hong Kong, 

Outcome

Type Measure Description Time frame Safety issue
Primary Corneal Staining Corneal staining was evaluated in 5 corneal regions (Central, Inferior, Nasal, Temporal and Superior) using Sodium Fluorescein strips. The corneal Staining was graded using the scale Grade 0: No Staining, Grade 1: Trace(Minimal superficial staining or stippling), Grade 2: Mild (Regional or diffuse punctate staining), Grade 3:Moderate(Significant dense coalesced staining, corneal abrasion or foreign body tracks.), Grade 4 Severe(Severe abrasions greater than 2 mm in diameter, ulcerations, epithelial loss, or full thickness abrasion.). The total was calculated by using the sum across all regions by time point. The range for the total grade for each time point would be 0-20. The total average grade for each lens and time point was evaluated as an average change from baseline level of corneal staining. 20 minutes and 7 hours post lens fitting
See also
  Status Clinical Trial Phase
Recruiting NCT04075591 - Wavefront-guided LASIK for Monovision Treatment of Myopic Subjects With Presbyopia N/A
Completed NCT03169153 - Clinical Comparison of Silicone Hydrogel Monthly Lenses N/A
Completed NCT02517567 - DAILIES TOTAL1® - Comparative Assessment of Tear Film Evaporation N/A
Recruiting NCT02844556 - International Multicenter Study on SMILE Surgery N/A
Completed NCT02235831 - DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance N/A
Completed NCT02214797 - Dispensing Study to Assess Visual Performance of Prototype Contact Lenses N/A
Completed NCT01941498 - WaveLight® Refractive Myopic Study N/A
Completed NCT01917162 - Multi-Center Clinical Evaluation of Two Daily Disposable Contact Lenses (Study 2) N/A
Completed NCT01629706 - Determination of Cell Population in Solution-Induced Corneal Staining (SICS) and Symptomatic Versus Asymptomatic Lens Wearers N/A
Completed NCT01440322 - AIR OPTIX® COLORS Registration Trial N/A
Completed NCT01233089 - Fitting Children With Contact Lenses N/A
Completed NCT01211535 - Subjective Comfort With Multipurpose Care Solutions in Soft Contact Lens Wearers N/A
Completed NCT01163760 - Clinical Evaluation of Two Daily Disposable Contact Lenses N/A
Completed NCT02484586 - Dispensing Study to Assess the Visual Performance of Optimised Prototype Contact Lenses N/A
Completed NCT02252133 - DAILIES TOTAL1® Lens Centration in a Japanese Population N/A
Completed NCT02103309 - Comparative Evaluation of Contact Lens Centering of DAILIES® AquaComfort Plus® Versus 1-DAY ACUVUE® MOIST® in Japan N/A
Completed NCT01941485 - WaveLight® Refractive Flap Accuracy Study N/A
Completed NCT01951573 - Evaluation of a New Daily Disposable Multifocal Contact Lens Design N/A
Recruiting NCT01718184 - Piggyback Sulcoflex Toric IOL for Correcting Refractive Error Following Corneal Transplantation N/A
Completed NCT01997216 - Multifocal Lens Design Evaluation N/A