Clinical Trials Logo

Clinical Trial Summary

In patients under general anesthesia, the prevention of intraoperative hypotension to maintain blood pressure (BP) close to the initial blood pressure, i.e. before anesthesia, is essential to reduce the risk of death and improve surgical outcomes. Vasoactive agents are commonly used to correct this hypotension (Phenylephrine Ephedrine Noradrenaline). These three vasoconstrictors have specific effects on the afterload of the heart and can impair its function. The analysis of the left ventricular pressure-volume curve (PV Loop) allows continuous information on the post-charge state of the left ventricle and the changes induced by the vasoconstrictors to be observed. However, the investigators currently have no way of monitoring these effects. In clinical practice if these loops are obtained non-invasively they can be used in the evaluation of cardiac function of at-risk patients in perioperative and also in intensive care to allow therapeutic adaptation.


Clinical Trial Description

Investigators have conducted several studies on the differential effects of different vasopressors used in general anesthesia to correct sympatholysis-induced hypotension occurring under anesthetic drugs and after eliminating hypovolemia or overdose in anesthetics. In a pilot study investigators described a method for analyzing Velocity-Pressure interactions to monitor ventricular afterload in the operating room with the construction of Velocity-Pressure aortic loops (VP Loop). These loops were constructed from an aortic velocity signal measured by esophageal Doppler and aortic blood pressure signal from a femoral catheter. The Global Afterload Angle (GALA) measured on the loop were then higher in patients at cardiovascular risk (RCV+) at 68 ± 6° compared to 41 ± 15° in patients (RCV-) (p<0.001). In addition, GALA variations were associated with variations in the three components of ventricular afterload: compliance, resistance and waves reflection. Finally, under the effect of vasopressors, there was a modification in the shape of the VP Loop and the value of GALA, showing GALA as a reliable marker potential for ventricular afterload in patients under general anesthesia. In order to develop a totally non-invasive method that would produce a pressure velocity curve, the investigators propose to combine an estimation of aortic pressure by a tonometry method and an estimation of ventricular volumes by three-dimensional echocardiography. The main objective of this study is then to compare VP Loop parameters obtained non-invasively to VP loop obtained invasively according to patient cardiovascular risk factors. Cardiac afterload can be schematically defined by the combination of three components: peripheral vascular resistance (PVR), total arterial compliance (Ctot) and aortic wave reflections (WR). WR could be assessed by pulse wave pressure analysis with the augmentation index (Aix) or after pulse wave pressure separation into a forward and backward wave with the wave reflection index (WRi) or the wave reflection area (WRa). Invasive Aortic pressure measurements: As required by the standard of care of the interventional neuroradiology procedure, the neuroradiologist also cannulated the femoral artery. At the end of the procedure, during catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe. Descending aortic velocity is measured with a transesophageal Doppler CardioQ-ODM+ monitor (Deltex Medical, Chichester, UK) in order to construct the VP Loop in descending thoracic aorta. Non-invasive Non-invasive Aortic velocity recording VP Loop in aorta is measured in the flushing chamber of the left ventricle from the apical five chamber view by trans-thoracic echocardiography (TTE) (Philips, EPIQ 7). Estimation of ventricular diastolic pressure by measuring mitral and aortic flow gradients by echocardiography (EPIQ G7 Philips© or similar) Determination of left ventricular volumes during the cardiac cycle by echocardiography (3D EPIQ G7 Philips© or similar). Non-invasive central pressure measurement by an arterial tonometer reconstructing the central aortic curve (ShygmoCor, AtCor©) The SphygmoCor radial tonometer (AtCor Medical, Pty Ltd, Sydney, Australia) is the most widely used tonometer in clinical research for non-invasive central pressure measurement and pulse wave analysis. The central blood pressure is then estimated using a validated radial-aortic transfer function. The tonometer requires prior calibration by mean (MAP) and diastolic (PAD) blood pressure measured with the conventional brachial cuff as validated in the literature. VP Loop construction Digitalization of pressure and velocity signals are performed with the IntelliVue MP60 monitor (Philips, Eindhoven, The Netherlands) at a sampling frequency of 125 Hz and saved using ixTrend software (IXELLENCE, Wildau, Germany) on a computer. Briefly, the velocity coordinates is plotted on the x axis and the pressure coordinates on the y axis. The investigators characterize the VP Loop by 4 points (A, B, C, D), allowing us to identify 3 angles: Alpha, Beta and GALA. The goal of this study is to compare these parameters of cardiac after load obtained non-invasively with the same parameters invasively obtained. Experimental design: This is a single-center, interventional, category II prospective study (minimal risks and constraints) Population concerned: Patients will be included if their perioperative risk required a continuous monitoring of mean arterial pressure (MAP) and cardiac output (CO). The study involves major patients under general anesthesia in interventional neuroradiology. Research Proceedings For all patients, data from trans-esophageal Doppler, trans-thoracic echocardiography (TTE) and hemodynamic data are collected at the end of the procedure. During catheter withdrawal, pressure waveforms are recorded in the descending thoracic aorta just in front of the esophageal Doppler probe. All data from monitoring are connected to the main monitor. Individual benefit: There is no benefit for the patient Collective benefit: Targeting mean arterial pressure (MAP) with boluses of selective peripheral vasopressors (without positive inotropic or chronotropic effects) could have deleterious effects on cardiac output. Thus, it seems important to use a combined analysis of MAP and CO with low invasive methods to estimate the Afterload-related cardiac performance (ACP) in surgical patients considered with "high cardiovascular risk". Risks and minimal constraints added by the research: No added risk. Patients are included if their perioperative risk required a continuous monitoring of MAP and CO. The standard of care for the interventional neuroradiology procedure needs a catheterization of the femoral artery using the Seldinger technique and insertion of a catheter. All the other ones measures are obtained non-invasively. Patients are assigned to one of two groups according to their risk of increased arterial stiffness as reported in cardiological publications. The criteria investigators used are as follows: age > 50 years old as a major criterion 20 and cardio-vascular risk factors (history of congestive heart failure, history of cardiovascular event, current smoking, diabetes mellitus, dyslipidemia, and arterial hypertension) as minor criteria. Patients were classified into the high risk group (Hi-risk) if they had at least one major criterion or two minor criteria or into the low risk group (Lo-risk) if they presented with no or one minor criterion. During their interventional neuroradiology procedure, all patients' routine monitoring will consist of electrocardiogram, pulsated oxygen saturation, endtidal carbon dioxide (CO2), respiratory rate, tidal volume and monitoring of neuromuscular function. For all patients whatever the comorbidities, anesthesia induction will be performed using a target-controlled infusion (Orchestra® Base Primea Fresenius Kabi France). According to our standard of care, intra-operative episodes of hypotension (mean arterial pressure (MAP) < 65 mmHg or < 80% baseline) are treated by Norepinephrine bolus of 10 µg. For all patients, data from trans-esophageal Doppler, trans-thoracic echocardiography (TTE) and hemodynamic data are collected at the end of the procedure. Number of selected subjects Selection of patients up to 55 analyzable patients Number of centers: 1 Research center Agenda inclusion period: 12 months duration of participation (treatment + follow-up): duration of the interventional neuroradiology procedure: 1 day Total duration: 12 months Number of planned inclusions by center and month: 2-3 Number of subjects required: 55 Statistics: Continuous data are expressed in median [interquartile] and qualitative data in n (%). The risk α has been set at 5%. The categorical variables will be compared by Mann-Whitney test and the continuous variables by Wilcoxon test. The concordance between the two methods will be evaluated by the intra-class correlation coefficient as well as by the Bland-Altman representation (with determination of bias and approval limits) for the various parameters of interest. Selection of patients until 55 analyzable patients is obtained (signal quality obtained and possible analysis). The estimate of the number of subjects to be included is based on the main evaluation criterion, the intra-class correlation coefficient. Thus, to highlight, an intra-class correlation coefficient of 0.9 with a confidence interval of 0.1, for an alpha risk of 5%, it is necessary to include 56 patients. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03921164
Study type Observational
Source Assistance Publique - Hôpitaux de Paris
Contact Joaquim MATEO, MD
Phone +33 1 49 95 83 74
Email joaquim.mateo@aphp.fr
Status Recruiting
Phase
Start date January 27, 2021
Completion date July 2023

See also
  Status Clinical Trial Phase
Recruiting NCT06442904 - Can a Digital Education Program in Radiographic Imaging Technique for Dental Professionals Improve Image Quality? N/A
Recruiting NCT04407325 - Tuberculosis Screening in Paraguayan Prisons N/A
Recruiting NCT04274881 - Surface Landmarks and C-length as Predictors of Depth of Right IJV Catheter Insertion: A TEE-Guided Study
Completed NCT04481711 - Total Knee Arthroplasty and Clinical Findings N/A
Completed NCT03756935 - Early Detection of Intra Operative Hypotension (IOH) During the Induction of General Anaesthesia
Enrolling by invitation NCT04894201 - Deep Learning to Summarize Findings in Dental Panoramic Radiographs
Not yet recruiting NCT06369883 - How Often and What Type of Deformity is Detected in All Spine Radiographs?
Completed NCT05076188 - PARamedical Abnormalties Detection of Traumatic Bone Lesion of the extremitIeS
Recruiting NCT03230994 - Cooperative Adenomyosis Network
Completed NCT02925936 - Choice of Tube Extremity in Emission of Lowest Radiation Dose in Pediatric Patients N/A
Completed NCT05176886 - Correct Tip Position of Central Venous Catheters
Completed NCT03853226 - Rational for the Use of Velocity-Pressure Loop in the Operating Room
Completed NCT03876379 - Brain Power Spectral Density Under Propofol
Enrolling by invitation NCT04403178 - Prevention of Hip Displacement in Children With Cerebral Palsy in Denmark
Enrolling by invitation NCT04398342 - Characteristics of Children With Cerebral Palsy Who Develops Hip Displacement in Denmark
Completed NCT03769142 - Cerebral Perfusion During Induction of General Anesthesia