Clinical Trials Logo

Clinical Trial Summary

Previous studies have documented that orthopedic injuries and musculoskeletal pain are a likely result of wearing heavy leaded aprons. This single-center, randomized 1-3 month clinical study compares conventional lead aprons and ancillary shields to the Rampart IC, M1128 radiation protection system in order to improve radiation safety with minimal orthopedic strain by using the RAMPART device. There will be three study arms, each arm requiring 21 procedures for a total of 63 total procedures, Each procedure will be randomized, instead of individual subjects. Each enrolled subject may be involved in more than one procedure/case. Randomization stratification will be 1:1:1 to either Rampart shield only, lead apron and ancillary shield, or lead apron and Rampart Shield. Real-time dosimeters will be used in each procedure to measure radiation attenuation.


Clinical Trial Description

Previous studies have documented that orthopedic injuries and musculoskeletal pain are a likely result of wearing heavy leaded aprons that are designed to shield interventionalists and laboratory staff from radiation. A large, multicenter study found that interventional laboratory employees reported a 67% increase in the prevalence of musculoskeletal pain. Two Society of Cardiovascular Angiography and Intervention (SCAI) surveys were performed a decade apart in 2004 and 2014 which both showed similar results on the orthopedic complications on the operators who wear leaded apron protection. The surveys revealed a 60% incidence of orthopedic issues and operators who have been operating greater than 20 years in the Cath Lab compared to a 2.3% incidence of chronic spine problems in the general population. Interestingly, of the operators who had been in practice less than 5 years, 26% already had orthopedic complaints. The study also revealed that over a third of those surveyed had already had to take spine related periods of absence from the catheterization lab. Though in recent years focus on individual radiation attenuation technologies that support both attenuation and orthopedic safety have evolved, the emphasis has been on the operator. A solution has not existed to address radiation attenuation and orthopedic safety for the entire scrubbed interventional team with one system. To address the challenge of radiation protection in this environment without the burden of wearing a heavy lead apron, Rampart IC, M1128 was created. Rampart IC, M1128 is a fully adjustable and portable system that provides radiation protection for operators and their team without having to wear a lead apron. This study will have three randomization arms, each arm requiring 21 procedures for a total of 63 total procedures. Randomization stratification will be based on procedure, not individual subject. Each enrolled subject may be involved in more than one procedure/case. Computer software will be utilized to randomize procedures in a 1:1:1 ratio to either lead apron with ancillary shield, Rampart IC, M1128, or lead apron with the Rampart IC, M1128. Real-time dosimeters will be placed on interventional staff's left temple, shoulder, and hip in order to measure radiation attenuation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05347290
Study type Interventional
Source Northwell Health
Contact
Status Completed
Phase N/A
Start date March 9, 2022
Completion date December 9, 2022

See also
  Status Clinical Trial Phase
Completed NCT03649451 - Reference Dose Levels During Fluoroscopically Guided Procedures in Operating Rooms
Completed NCT03305978 - Pulmonary Nodule Detection: Comparison of an Ultra Low Dose vs Standard Scan. N/A
Recruiting NCT04139096 - Genetic Susceptibility to Radiation Induced Thyroid Cancer
Completed NCT01430975 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning at Two Clinical Sites N/A
Completed NCT01424774 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning N/A
Completed NCT00378053 - A Prospective Study of Radiation Exposure to Surgeons N/A
Recruiting NCT05561439 - Individual Dosimetric Monitoring of Workers During Interventional Radiology and Cardiology Procedures for Cardiologists and Radiologists in France
Completed NCT04078165 - Suspended Personal Protection System Versus Conventional Protection (Aka Zero-Gravity vs Shield and Apron) N/A
Recruiting NCT04694391 - Genomic Study of Relapse Esophageal Cancer After Radiotherapy
Not yet recruiting NCT04403815 - Radiation Exposure During Coronary Procedures According to Vascular Access
Recruiting NCT04285944 - Operator Radiation Protection During Cardiac Catheterization Using Mavig X-ray Protective Drapes®. N/A
Completed NCT04363190 - Genomic Instability in Vascular Surgeons
Completed NCT04404257 - Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation N/A
Recruiting NCT04678258 - Zero Fluoroscopy Voltage Guided vs. Linear CTI Ablation N/A
Recruiting NCT03386500 - Safety Study of BMX-001 (Radio-protector) in Patients With Newly Diagnosed Anal Cancer Phase 1/Phase 2
Recruiting NCT05833516 - Hyper Adduction of Right Radial Artery/Arm vs Left Drag Over Technique
Recruiting NCT03946280 - Utility of 3D Navigation to Reduce Ionizing Radiation in Common Flutter Ablation. Study of Personnel and Patient Dosimetry N/A
Completed NCT03985488 - Radiation Exposure Assessment in Fluoroscopy
Completed NCT03605030 - Reducing Radiation Exposure to Operators During Invasive Cardiac Procedures N/A
Recruiting NCT02689908 - Individualized Radiation Dose Control N/A