Radiation Exposure Clinical Trial
Official title:
Utility of 3D Navigation to Reduce Ionizing Radiation in Common Flutter Ablation. Study of Personnel and Patient Dosimetry
Common Flutter ablation technique use low X-ray based three-dimension (3D) navigation for catheter tracking, have become a popular implementation to treat patient's underlying arrhythmia. Compared with fluoroscopy, the gold standard X-ray based method, this recent technique provides the required anatomical information and reduce risk associated with ionizing radiation exposure. Besides Practical Guidelines "as low as reasonably achievable (ALARA) to minimize and normalize radiation exposure had been published so far. The risk of developing acute radiation associated injuries still remains high. In the present study we will compare two groups of patients undergoing into cavotricuspid isthmus (CTI) ablation using either the 3D navigation ("Ensite NavX system") (n = 25) or conventional fluoroscopy (n = 25). Further developing the 3D navigation technique will help to increase safety during the treatment, for both patients and the personnel and increase the success rate during the electrophysiological (EP) interventional procedures.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03649451 -
Reference Dose Levels During Fluoroscopically Guided Procedures in Operating Rooms
|
||
Completed |
NCT03305978 -
Pulmonary Nodule Detection: Comparison of an Ultra Low Dose vs Standard Scan.
|
N/A | |
Recruiting |
NCT04139096 -
Genetic Susceptibility to Radiation Induced Thyroid Cancer
|
||
Completed |
NCT01430975 -
Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning at Two Clinical Sites
|
N/A | |
Completed |
NCT01424774 -
Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning
|
N/A | |
Completed |
NCT00378053 -
A Prospective Study of Radiation Exposure to Surgeons
|
N/A | |
Recruiting |
NCT05561439 -
Individual Dosimetric Monitoring of Workers During Interventional Radiology and Cardiology Procedures for Cardiologists and Radiologists in France
|
||
Completed |
NCT04078165 -
Suspended Personal Protection System Versus Conventional Protection (Aka Zero-Gravity vs Shield and Apron)
|
N/A | |
Recruiting |
NCT04694391 -
Genomic Study of Relapse Esophageal Cancer After Radiotherapy
|
||
Not yet recruiting |
NCT04403815 -
Radiation Exposure During Coronary Procedures According to Vascular Access
|
||
Recruiting |
NCT04285944 -
Operator Radiation Protection During Cardiac Catheterization Using Mavig X-ray Protective Drapes®.
|
N/A | |
Completed |
NCT04363190 -
Genomic Instability in Vascular Surgeons
|
||
Completed |
NCT04404257 -
Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation
|
N/A | |
Recruiting |
NCT04678258 -
Zero Fluoroscopy Voltage Guided vs. Linear CTI Ablation
|
N/A | |
Recruiting |
NCT03386500 -
Safety Study of BMX-001 (Radio-protector) in Patients With Newly Diagnosed Anal Cancer
|
Phase 1/Phase 2 | |
Recruiting |
NCT05833516 -
Hyper Adduction of Right Radial Artery/Arm vs Left Drag Over Technique
|
||
Completed |
NCT03985488 -
Radiation Exposure Assessment in Fluoroscopy
|
||
Completed |
NCT03605030 -
Reducing Radiation Exposure to Operators During Invasive Cardiac Procedures
|
N/A | |
Recruiting |
NCT02689908 -
Individualized Radiation Dose Control
|
N/A | |
Completed |
NCT05347290 -
Comparison Of Effective Radiation Shielding Between Rampart IC, M1128 Shield vs Conventional Apron And Shields In Clinical Interventional Procedures
|
N/A |