Clinical Trial Summary

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. In the recently published guideline of the Federal Office for Radiation Protection in Germany diagnostic reference levels (DRLs) for dose area products (DAP) are not defined for PTBD procedures due to insufficient data. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture.


Description:

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. Usually, radiation exposure in radiological interventions is measured by the dose area product (DAP). Diagnostic reference levels (DRLs) are based on the third quartiles (Q3) of the pooled dose area product (DAP) for the known interventional procedures. They have been introduced in the 1980s by the International Commission on Radiological Protection's (ICRP's) to reduce patients radiation exposure. In the recently published guideline of the Federal Office for Radiation Protection in Germany in 2016 DRLs are not defined for PTBD procedures due to insufficient data. Procedure complexity due to different techniques, patient anatomy, lesion characteristics and disease severity makes it difficult to define DRLs in this fluoroscopy-guided intervention. The ICRP recently published some recommendations on DRLs in medical imaging including radiological interventions. As DRLs are often missing in this field, it was suggested to analyze national data sets comprising dosimetric data from a large number of facilities. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased or decreased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture. A questionnaire was sent to 200 gastroenterological and radiological departments in university and non-university hospitals to analyze the last 10 - 30 consecutively performed PTBD procedures.


Recruitment information / eligibility

Status Completed
Enrollment 600
Est. completion date October 15, 2018
Est. primary completion date August 15, 2018
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- 10 up to 30 consecutively performed PTBDs are documented in the study center

- body weight of the examined patients is about 60 - 80 kilogramms

- returned questionaire is complete in regard to DAP, fluoroscopy time, number of still images, characters of the intervention, characterization of the fluoroscopy device (manufacturer, date of first registration)

Exclusion Criteria:

- the study center performs less than 10 PTBDs/year

- returned questionaire is incomplete

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
Percutaneous biliary drainage
The initial puncture of the bile duct with an access needle is performed by ultrasound guidance or by fluoroscopic guidance. After injection of the radiopaque contrast media into the bile duct system the rest of the examination is performed by fluoroscopic guidance. All different PTBD procedures are analyzed: insertion, exchange or removal of a plastic catheter, metal stent implantation, PTBD with cholangioscopy, PTBD with ballon dilatation, PTBD with lithotrypsy or diagnostic percutaneous transhepatic cholangiography.

Locations

Country Name City State
Germany Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes Klinik für Innere Medizin II - Gastroenterologie und Endokrinologie Bad Homburg

Sponsors (2)

Lead Sponsor Collaborator
Theresienkrankenhaus und St. Hedwig-Klinik GmbH The Federal Office for Radiation Protection, Germany

Country where clinical trial is conducted

Germany, 

References & Publications (3)

Kloeckner R, Bersch A, dos Santos DP, Schneider J, Düber C, Pitton MB. Radiation exposure in nonvascular fluoroscopy-guided interventional procedures. Cardiovasc Intervent Radiol. 2012 Jun;35(3):613-20. doi: 10.1007/s00270-011-0206-y. Epub 2011 Jul 27. — View Citation

Ruiz-Cruces R, Vano E, Carrera-Magariño F, Moreno-Rodriguez F, Soler-Cantos MM, Canis-Lopez M, Hernández-Armas J, Diaz-Romero FJ, Rosales-Espizua F, Fernandez-Soto JM, Sanchez-Casanueva R, Martin-Palanca A, Perez-Martinez M, Gil-Agudo A, Zarca-Diaz MA, Parra-Osorio V, Muñoz Ruiz-Canela JJ, Moreno-Sanchez T, Lopez-Medina A, Moreno-Saiz C, Galan-Montenegro P, Gallego-Beuter JJ, Gonzalez-de-Garay M, Zapata-Jimenez JC, Pastor-Vega JM, Cañete S. Diagnostic reference levels and complexity indices in interventional radiology: a national programme. Eur Radiol. 2016 Dec;26(12):4268-4276. Epub 2016 Jul 6. — View Citation

Stratakis J, Damilakis J, Hatzidakis A, Perisinakis K, Gourtsoyiannis N. Radiation dose and risk from fluoroscopically guided percutaneous transhepatic biliary procedures. J Vasc Interv Radiol. 2006 Jan;17(1):77-84. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Radiation Exposure Radiation Exposure for the patient is measured by the dose area product (cGy x cm2 resp.µGy x·m2) From the beginning of the radiological examination until the end the examination (15 - 180 minutes)
Secondary Fluoroscopy time Accumulated fluoroscopy time for the complete examination (minutes) From the beginning of the radiological examination until the end the examination (15 - 180 minutes)
Secondary Number of images Number of still images which are produced during the whole examination (n) From the beginning of the radiological examination until the end the examination (15 -180 minutes)
See also
  Status Clinical Trial Phase
Completed NCT03649451 - Reference Dose Levels During Fluoroscopically Guided Procedures in Operating Rooms
Completed NCT03305978 - Pulmonary Nodule Detection: Comparison of an Ultra Low Dose vs Standard Scan. N/A
Recruiting NCT04139096 - Genetic Susceptibility to Radiation Induced Thyroid Cancer
Completed NCT01430975 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning at Two Clinical Sites N/A
Completed NCT01424774 - Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning N/A
Completed NCT00378053 - A Prospective Study of Radiation Exposure to Surgeons N/A
Recruiting NCT05561439 - Individual Dosimetric Monitoring of Workers During Interventional Radiology and Cardiology Procedures for Cardiologists and Radiologists in France
Completed NCT04078165 - Suspended Personal Protection System Versus Conventional Protection (Aka Zero-Gravity vs Shield and Apron) N/A
Recruiting NCT04694391 - Genomic Study of Relapse Esophageal Cancer After Radiotherapy
Not yet recruiting NCT04403815 - Radiation Exposure During Coronary Procedures According to Vascular Access
Recruiting NCT04285944 - Operator Radiation Protection During Cardiac Catheterization Using Mavig X-ray Protective Drapes®. N/A
Completed NCT04363190 - Genomic Instability in Vascular Surgeons
Completed NCT04404257 - Reduce Radiation Exposure in Fluoroscopic Interventions Evaluation N/A
Recruiting NCT04678258 - Zero Fluoroscopy Voltage Guided vs. Linear CTI Ablation N/A
Recruiting NCT03386500 - Safety Study of BMX-001 (Radio-protector) in Patients With Newly Diagnosed Anal Cancer Phase 1/Phase 2
Recruiting NCT05833516 - Hyper Adduction of Right Radial Artery/Arm vs Left Drag Over Technique
Recruiting NCT03946280 - Utility of 3D Navigation to Reduce Ionizing Radiation in Common Flutter Ablation. Study of Personnel and Patient Dosimetry N/A
Completed NCT03985488 - Radiation Exposure Assessment in Fluoroscopy
Completed NCT03605030 - Reducing Radiation Exposure to Operators During Invasive Cardiac Procedures N/A
Recruiting NCT02689908 - Individualized Radiation Dose Control N/A