Radial Artery Clinical Trial
Official title:
Reference Diameter and Characteristics of Distal Radial Artery by Ultrasonographic Assessement in Korean Patients
Radial access is recommended as the standard approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI) based on the evidence in which RA reduced mortality and bleeding events compared with femoral access. Recently, the use of distal radial artery (DRA) is rapidly increasing in accordance with the publication of several studies that have shown easy hemostasis, reduced bleeding complications and low arterial occlusion rate via distal radial approach. However, the diameter of DRA is relatively smaller than radial artery (RA) which can limit the widespread use of this access route. Regarding the size discrepancy, there is a lack of evidence to guide which patients are acceptable or not for CAG and PCI. Therefore, the main purpose of this study was to provide the reference diameter of DRA using ultrasonography in Korean patients. The clinical predictors for small DRA also were evaluated.
Radial access is recommended as the standard approach for coronary angiography (CAG) and
percutaneous coronary intervention (PCI) based on the evidence in which RA reduced mortality
and bleeding events compared with femoral access. Recently, the use of distal radial artery
(DRA) is rapidly increasing in accordance with the publication of several studies that have
shown easy hemostasis, reduced bleeding complications and low arterial occlusion rate via
distal radial approach. However, the diameter of DRA is relatively smaller than radial artery
(RA) which can limit the widespread use of this access route. Regarding the size discrepancy,
there is a lack of evidence to guide which patients are acceptable or not for CAG and PCI.
Therefore, the main purpose of this study was to provide the reference diameter of DRA using
ultrasonography in Korean patients. The clinical predictors for small DRA also were
evaluated.
Assessment of arterial diameter by ultasonography Patients were lying on the bed with
relaxation in an quiet room. The outer diameters of both DRA and RA were assessed by a
perpendicular angle using a linear ultrasound probe (3-4-10.8 MHz) and the average values
were recorded. The diameter of RA was measured from 2-3 cm above wrist crease. Anatomical
landmark for the measurement of DRA was the bony surface area just distal space from extensor
pollicis longus tendon in which the DRA was best palpable then runs down between the first
metacarpal and second metacarpal bone (just out of anatomical snuffbox area)
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT04257747 -
Qualitative and Quantitative Evaluation of Vascular Flows of Radial, Ulnar and Interdigital Arterial Trees Under Normal and Pathological Conditions by 3 Tesla MRI
|
N/A | |
Completed |
NCT03626129 -
Oximetry Guided Versus Traditional Rapid Deflation Technique for Achieving Hemostasis After Radial Procedures
|
N/A | |
Completed |
NCT05982366 -
Feasibility and Safety of the Routine Distal Transradial Approach
|
N/A | |
Completed |
NCT05771935 -
Ultrasound Guided Ulnar Versus Radial Artery in Pediatrics Undergoing Major Non Cardiac Surgery
|
N/A | |
Recruiting |
NCT04802252 -
A Diagnostic Study of Abnormal Acoustic Waves in Modern Pulse in Benign Prostatic Hyperplasia
|
||
Completed |
NCT04001764 -
Comparison of the Efficacy of Radial Artery Catheterization in Three Different Regions in Intensive Care Patients
|
N/A | |
Recruiting |
NCT04717661 -
A Diagnostic Test Study of Characteristic Sound Waves in Radial Artery of Early Pregnant Women
|
||
Completed |
NCT04761237 -
The Value of Central Venous-arterial Carbon Dioxide Difference
|
N/A | |
Completed |
NCT01789801 -
A Randomized Study Evaluating the Role of Ultra-sound Guidance When Drawing Radial Arterial Blood Samples
|
N/A | |
Recruiting |
NCT03405428 -
Ultrasonography For Radial Artery Diameter Measurement And Its Correlation With Allen Test
|
N/A | |
Completed |
NCT03620383 -
Radial Artery Vasodilation Heat Study
|
Phase 1/Phase 2 | |
Completed |
NCT01189188 -
Ultrasound Guidance for Radial Arterial Blood Sampling
|
N/A | |
Recruiting |
NCT04859712 -
A Diagnostic Test of Abnormal Sound Waves in Modern Pulsology of Lumbar Disc Herniation
|
||
Recruiting |
NCT04857736 -
A Diagnostic Test Study of Characteristic Sound Waves in Radial Artery During Menstruation in Healthy Female College Students
|
||
Recruiting |
NCT04861883 -
A Diagnostic Test Study of Characteristic Sound Waves in the Middle and Third Trimester of Pregnancy Women
|
||
Not yet recruiting |
NCT05511675 -
The Effect of Cold Application on the Hemostasis, Extremity Pain And Terumo Band Usage After Transradial Angiography
|
N/A |