Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03608995
Other study ID # CHU-394
Secondary ID 2018-A00619-46
Status Recruiting
Phase N/A
First received
Last updated
Start date August 21, 2018
Est. completion date May 30, 2020

Study information

Verified date August 2018
Source University Hospital, Clermont-Ferrand
Contact Lise Laclautre
Phone 04 73 75 49 63
Email drci@chu-clermontferrand.fr
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The primary purpose of the protocol is to compare the diagnostic accuracy in terms of positive and negative predictive values of Premaquick © (combined detection of IL-6 / IGFBP-1 total / IGFBP-1 native) and Quikcheck fFN ™ (fibronectin detection) tests for prediction of spontaneous delivery within 7 days in women with threatened preterm labor. The study hypothesis is that combined detection of IL-6 / IGFBP-1 total / IGFBP-1 native dice the admission will improve the prediction of delivery compared to the detection of fetal fibronectin alone in women with threatened preterm labor.


Description:

The threat of premature labour is the main cause of hospitalization during pregnancy (38% of hospitalizations). To date, the assessment of severity relies mainly on ultrasound measurement of the cervix. The length of the cervix is significantly correlated with the risk of spontaneous premature delivery. A threshold of 25mm is relevant to rule out a delivery within 7 days but the identification of new markers including biological would be interesting to guide the clinician in assessing the risk of preterm birth. Among the biomarkers measured in vaginal secretions, the detection of fetal fibronectin seems to be the most relevant because of a high negative predictive value (NPV) up to 100% to rule out a delivery within 7 days. However, the use of this test is discussed because of its low positive predictive value (PPV) to predict delivery within 7 days (from 11% to 48%). The use of Premaquick © test (Biosynex, Strasbourg, France), which allow the simultaneous quantification of IL-6, total IGFBP-1 and native IGFBP-1 could be more efficient compared to the detection of fibronectin by improving the VPP. The results already obtained on a cohort of 97 patients (Eleje et al., 2016) show a similar NPV and a higher PPV of the Premaquick© test compared to the Quikcheck fFN ™ test (PPV up to 95% when the 3 markers are positive). Investigator wish to conduct a comparative study between these two tests on a larger cohort of patients (n = 220). Results of the tests will be masked for the clinician and the patient in order to assess and compare their ability to predict delivery within 7 days without modify the current medical management.


Recruitment information / eligibility

Status Recruiting
Enrollment 220
Est. completion date May 30, 2020
Est. primary completion date December 30, 2019
Accepts healthy volunteers No
Gender Female
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Major pregnant women admitted to Clermont-Ferrand CHU maternity for threatened preterm delivery with intact membranes between 24 and 34 (+6 days) week of amenorrhea, with length of cervix < 30mm (ultrasound measurement).

- Ability to give informed consent.

- French social security scheme.

Exclusion Criteria:

- - Dilation of the cervix = 4 cm

- Triple pregnancy or more

- Fetal membranes rupture

- Known uterine malformation

- Hydramnios

- Fetal malformation

- Placenta previa

- Abundant metrorrhagia

- Patient who had already participated in the study during the same pregnancy

- Patient under guardianship or curatorship

Study Design


Intervention

Diagnostic Test:
Premaquick (Diagnostic test)
PREMAQUICK® is a rapid multiparametric test which aim to detect the presence of IGFBP-1 (Insulin-like Growth Factor-Binding Protein 1), fragmented IGFBP-1 and IL-6 (Interleukin 6) in vaginal secretions. By combining biomarkers of myometrial activation, cervical maturity and inflammation / infection, PREMAQUICK® integrates the main pathogenic mechanisms responsible for premature delivery, which makes it possible to predict or, on the contrary, rule out the risk of childbirth within 7 to 14 days. This test is intended for in vitro diagnostic use. Vaginal secretions are collected under speculum with a swab (10 seconds of impregnation of the swab). The swab is immersed in a tube containing an extraction buffer for 10 seconds. The tube is mixed and then 3 drops are deposited in each wells of the test device for 10 minutes. Visual reading should be done between 10 and 15 minutes.
Quikcheck fFN ™
- The Hologic QuikCheck fFN test is intended to be used for the qualitative detection of fetal fibronectin in cervicovaginal secretions. The presence of fetal fibronectin in cervicovaginal secretions between 22 weeks, 0 days and 34 weeks, 6 days of gestation is associated with elevated risk of preterm delivery. Quick Check fFN test® is a 10 min, one-step, visual test consists of a sterile polyester-tipped applicator, fetal fibronectin test strip, and sample extraction buffer. The QuikCheck fFN is a solid-phase immunogold assay which aim to detect fetal fibronectin. A positive specimen will result in two visible lines and a negative specimen will result in one visible line (control).

Locations

Country Name City State
France CHU Clermont-Ferrand Clermont-Ferrand

Sponsors (2)

Lead Sponsor Collaborator
University Hospital, Clermont-Ferrand Mr. Thierry PAPER – Biosynex Company

Country where clinical trial is conducted

France, 

References & Publications (4)

Compan C, Rossi A, Piquier-Perret G, Delabaere A, Vendittelli F, Lemery D, Gallot D. [Prediction of spontaneous preterm birth in symptomatic patients: A review]. J Gynecol Obstet Biol Reprod (Paris). 2015 Oct;44(8):740-51. doi: 10.1016/j.jgyn.2015.06.008. Epub 2015 Jun 29. Review. French. — View Citation

Deplagne C, Maurice-Tison S, Coatleven F, Vandenbossche F, Horovitz J. [Sequential use of cervical length measurement before fetal fibronectin detection to predict spontaneous preterm delivery in women with preterm labor]. J Gynecol Obstet Biol Reprod (Paris). 2010 Nov;39(7):575-83. doi: 10.1016/j.jgyn.2010.08.001. Epub 2010 Sep 29. French. — View Citation

Eleje GU, Ezugwu EC, Eke AC, Eleje LI, Ikechebelu JI, Ezebialu IU, Obiora CC, Nwosu BO, Ezeama CO, Udigwe GO, Okafor CI, Ezugwu FO. Accuracy of a combined insulin-like growth factor-binding protein-1/interleukin-6 test (Premaquick) in predicting delivery in women with threatened preterm labor. J Perinat Med. 2017 Nov 27;45(8):915-924. doi: 10.1515/jpm-2016-0339. — View Citation

Sentilhes L, Sénat MV, Ancel PY, Azria E, Benoist G, Blanc J, Brabant G, Bretelle F, Brun S, Doret M, Ducroux-Schouwey C, Evrard A, Kayem G, Maisonneuve E, Marcellin L, Marret S, Mottet N, Paysant S, Riethmuller D, Rozenberg P, Schmitz T, Torchin H, Langer B. [Prevention of spontaneous preterm birth (excluding preterm premature rupture of membranes): Guidelines for clinical practice - Text of the Guidelines (short text)]. J Gynecol Obstet Biol Reprod (Paris). 2016 Dec;45(10):1446-1456. doi: 10.1016/j.jgyn.2016.09.011. Epub 2016 Nov 9. Review. French. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Diagnostic value of Premaquick and Quikcheck fFN ™ tests to predict delivery within 7 days (yes / no). The results (positive / negative) of the Premaquick and Quikcheck fFN ™ tests and the delay between the test and delivery time (in days) will allow to determine the PPV and NPV of the tests to predict delivery within 7 days. Results of the tests are given by the biochemistry department after a minimum of 15 days after the tests have been performed. The date of delivery is obtained by analyzing the patient file.
Secondary Number of positive markers of the Premaquick test Number of positive / negative markers (0, 1, 2 or 3) up to 17 weeks
Secondary Number of negative markers of the Premaquick test Number of positive / negative markers (0, 1, 2 or 3) up to 17 weeks
See also
  Status Clinical Trial Phase
Active, not recruiting NCT06168149 - The Relationship of Fetal Lung Elastography Values With the Development of Respiratory Distress in Cases of Preterm Labor
Completed NCT02538718 - Efficacy and Safety of MgSO4 as Tocolytics Compared to Ritodrine in Preterm Labor N/A
Not yet recruiting NCT05864066 - Cyclin-dependent Kinase Inhibitor 2A (Placental Senescence Marker) on Labor-related Signals
Terminated NCT03715530 - Use of Placental Alpha Microglobulin-1(PAMG-1) to Diagnose Premature Rupture of Membranes in Pregnant Women N/A
Recruiting NCT03638037 - Correlation Between Maternal Vitamin D Level And Preterm Birth
Recruiting NCT03992534 - The FLIP-1 Study: Vaginal Lactobacillus Supplementation in Women at High Risk of Preterm Birth Phase 1
Withdrawn NCT03122704 - Group B Streptococcus (GBS) Infection and in Preterm Labor Women Conceived Through IVF N/A
Completed NCT02536352 - Effect of Supplementation of Fluoride on Maternal Periodontal Health, Preterm Delivery, and Perinatal Well-Being Early Phase 1
Recruiting NCT01518816 - Role of Serum Total Antioxidant Level in Preterm Labor N/A
Recruiting NCT04590677 - Prediction of the Onset of Term and Preterm Labour
Completed NCT03112018 - Strengthening Facility-based Intrapartum/Immediate Newborn Care to Reduce Mortality of Preterm Infants in Migori County, Kenya and Busoga Region, Uganda N/A
Active, not recruiting NCT04301518 - Prematurity Risk Assessment Combined With Clinical Interventions for Improving Neonatal outcoMEs N/A
Completed NCT03785795 - Multichannel EMG Diagnosing True Preterm Labor
Withdrawn NCT02351310 - Effectiveness of ACS in Extreme Preemies Phase 3
Not yet recruiting NCT01985594 - Utrogestan Versus Nifedipine as Tocolysis for Preterm Labor: a Randomised Controlled Trial Phase 2
Not yet recruiting NCT04532086 - Uterocervical Angle and Preterm Labour
Completed NCT04605172 - Lockdown Impact on Spontaneous Premature Birth in a Level III NICU
Recruiting NCT04417595 - Investigating N-3 Fatty Acids to Prevent Neonatal Tobacco-related outcomeS Phase 2
Completed NCT03923023 - Impact of the PREEMI Package on Neonatal Mortality
Recruiting NCT06157203 - Labor Status Monitor for Diagnosing True vs False Labor in Preterm Patients