Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT04739085
Other study ID # ES1/Th4/21-1-2021
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date November 20, 2020
Est. completion date May 20, 2021

Study information

Verified date January 2021
Source Democritus University of Thrace
Contact Georgios Labiris, MD, PhD
Phone 00302551030405
Email labiris@usa.net
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

The primary objective of this study is to compare the level of agreement between clinical defocus curves and the web Democritus Digital Acuity Reading Test (wDDART), which is a web-based digital near and intermediate vision reading test.


Description:

The 'defocus curve' assessment technique aims to simulate different distances from near to far over which the patient's visual acuity (VA) is evaluated. Defocus curves are created by first measuring best-corrected distance and near VA of the examinee. Then, a series of positive- and negative-powered trial lenses are added to the best-corrected distance visual acuity (BCDVA) of the patient's eye. Viewing through the addition of a minus lens creates divergent light rays with the same refractive effect as bringing the eye chart closer to the viewer. For instance, a -2.50 D lens represents the distance of 40 cm. The "defocus curve" assessment technique is a method used widely for the assessment of the functional vision range following multifocal intraocular lens (IOL) implantation. Since this method is a simulation of the near vision, it would be ideal if near vision could be evaluated objectively with a near vision chart. However, the conventional printed near vision charts are not available for a variety of reading distances. In addition, the measurement of near VA at different distances with a printed reading chart intended for one predefined distance (e.g. printed chart for 40 cm) and the transformation of the reading score at 40 cm to an equivalent score for the examined distances is impractical in clinical setting. For this reason, a digital reading test that allows the text calibration for all reading distances could be a practical method for the rapid and ease evaluation of the near VA, especially in patients implanted with multifocal IOLs. The web-based digital near and intermediate vision reading test wDDART offers the ability to estimate VA at different distances with automated measurement of the patient-screen distance. Therefore, the present study aims to investigate the level of agreement between clinical defocus curves and the web-based digital near and intermediate vision reading test wDDART.


Recruitment information / eligibility

Status Recruiting
Enrollment 100
Est. completion date May 20, 2021
Est. primary completion date March 20, 2021
Accepts healthy volunteers No
Gender All
Age group 40 Years to 80 Years
Eligibility Inclusion Criteria: - Previous cataract lens extraction, age> 40 years, monocular best corrected distance visual acuity > 7/10 Exclusion Criteria: - Glaucoma, corneal diseases, macular diseases, postoperative opacification of the posterior capsule, former mental diseases

Study Design


Related Conditions & MeSH terms


Intervention

Diagnostic Test:
Defocus curves - Monocular distance visual acuity with trial lenses added to the best correction for distance
The monocular distance visual acuity of each participant' eye is evaluated using trial lenses of -3.00 sph, -2.50 sph, -1.75 sph, and -1.25 sph (added to the best correction for distance), which correspond to distances 30 cm, 40 cm, 60 cm and 80 cm, respectively.
wDDART - Monocular near visual acuity using the best correction for distance
The same participants undergo visual acuity test via the web-based digital near vision reading test wDDART at 30 cm, 40 cm, 60 cm and 80 cm, having their best correction for distance.

Locations

Country Name City State
Greece Department of Ophthalmology, University Hospital of Alexandroupolis Alexandroupolis Evros

Sponsors (1)

Lead Sponsor Collaborator
Democritus University of Thrace

Country where clinical trial is conducted

Greece, 

References & Publications (1)

Labiris G, Panagiotopoulou EK, Chatzimichael E, Tzinava M, Mataftsi A, Delibasis K. Introduction of a digital near-vision reading test for normal and low vision adults: development and validation. Eye Vis (Lond). 2020 Oct 22;7:51. doi: 10.1186/s40662-020-00216-0. eCollection 2020. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Distance-corrected near visual acuity (DCNVA) at 30 cm via defocus curves The monocular distance visual acuity of each participant's eye is evaluated using a trial lens of -3.00 sph (added to the best correction for distance), which corresponds to the distance of 30 cm through study completion, 6 months
Primary Distance-corrected near visual acuity (DCNVA) at 40 cm via defocus curves The monocular distance visual acuity of each participant's eye is evaluated using a trial lens of -2.50 sph (added to the best correction for distance), which corresponds to the distance of 40 cm through study completion, 6 months
Primary Distance-corrected intermediate visual acuity (DCIVA) at 60 cm via defocus curves The monocular distance visual acuity of each participant's eye is evaluated using a trial lens of -1.75 sph (added to the best correction for distance), which corresponds to the distance of 60 cm through study completion, 6 months
Primary Distance-corrected intermediate visual acuity (DCIVA) at 80 cm via defocus curves The monocular distance visual acuity of each participant's eye is evaluated using a trial lens of -1.25 sph (added to the best correction for distance), which corresponds to the distance of 80 cm through study completion, 6 months
Primary Distance-corrected near visual acuity (DCNVA) at 30 cm via wDDART The monocular near (30 cm) visual acuity of each participant's eye is evaluated using the best correction for distance through study completion, 6 months
Primary Distance-corrected near visual acuity (DCNVA) at 40 cm via wDDART The monocular near (40 cm) visual acuity of each participant's eye is evaluated using the best correction for distance through study completion, 6 months
Primary Distance-corrected intermediate visual acuity (DCIVA) at 60 cm via wDDART The monocular intermediate (60 cm) visual acuity of each participant's eye is evaluated using the best correction for distance through study completion, 6 months
Primary Distance-corrected intermediate visual acuity (DCIVA) at 80 cm via wDDART The monocular intermediate (80 cm) visual acuity of each participant's eye is evaluated using the best correction for distance through study completion, 6 months
See also
  Status Clinical Trial Phase
Completed NCT05326607 - Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia N/A
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Completed NCT05495971 - Extended Depth of Focus Contact Lenses for Presbyopia N/A
Completed NCT05464732 - Vivity IOL: Emmetropia Compared to Monovision. N/A
Recruiting NCT06045299 - Evaluation of the Efficacy and Safety of LNZ101 and LNZ100 for the Presbyopia Phase 3
Active, not recruiting NCT04151550 - Safety & Efficacy of the Laser Scleral Microporation Procedure (Philippines) N/A
Not yet recruiting NCT05506553 - Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision N/A
Completed NCT02554396 - Evaluation of the Efficacy and Safety of PRX-100 in the Treatment of Early to Moderate Presbyopia Phase 2
Completed NCT02235831 - DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance N/A
Completed NCT02214797 - Dispensing Study to Assess Visual Performance of Prototype Contact Lenses N/A
Enrolling by invitation NCT01443585 - Clinical Evaluation of a Progressive Addition Lens (PAL) N/A
Completed NCT01591499 - Clinical Evaluation of Biofinity Multifocal Compared With Air Optix Aqua Multifocal and With PureVision Multifocal N/A
Completed NCT04983589 - A Study to Assess Safety and Efficacy in Participants Age 40 to 55 With Presbyopia (Old Eye) Who Receive AGN-190584 in Both Eyes Twice Daily Phase 3
Completed NCT02740010 - The Visual Performances of a Progressive Multifocal Intraocular Lens With Extended Depth of Focus
Recruiting NCT05796453 - Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix N/A
Completed NCT02516306 - A Study to Evaluate the Safety and Efficacy of EV06 Ophthalmic Solution in Improving Vision in Subjects With Presbyopia Phase 1/Phase 2
Completed NCT05359380 - The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
Not yet recruiting NCT04522427 - Study of Presbyopia-correcting Intraocular Lenses in Eyes With Previous Corneal Refractive Surgery N/A
Completed NCT03688425 - Comparison of Clinical Outcomes POD L GF vs POD F GF in Asian Eyes N/A
Recruiting NCT06053463 - Evaluation of Soft Multifocal Lenses in Presbyopic Previous Contact Lens Wearers N/A