Presbyopia Clinical Trial
NCT number | NCT02450747 |
Other study ID # | CR-5692 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | April 2015 |
Est. completion date | September 2015 |
Verified date | November 2016 |
Source | Johnson & Johnson Vision Care, Inc. |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
This is a four week study to evaluate the performance of a multifocal contact lens in habitual wearers of silicone hydrogel multifocal contact lenses.
Status | Completed |
Enrollment | 44 |
Est. completion date | September 2015 |
Est. primary completion date | September 2015 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 40 Years to 70 Years |
Eligibility |
Inclusion Criteria: 1. Healthy adult males or females age 40 to 70 and has full legal capacity to volunteer. 2. The subject is a current spherical silicone hydrogel multifocal (SiHy) contact lens wearer (defined as a minimum of 2 days per week for at least 6 hours of Daily Wear contact lenses, for a minimum of one month prior to the study) and willing to wear the study lenses on a daily basis (defined as a minimum of 6 hours of wear per day) for the duration of the study. 3. The subject must own a pair of wearable spectacles to wear when they cannot wear the study lenses. 4. The subject's optimal vertexed spherical equivalent distance correction must be between +3.50 and -5.50 Diopters (D) (inclusive) in both eyes. 5. Subjective refraction cylinder power must be less than or equal to 0.75 D in both eyes. 6. Requires a reading addition of +0.75 D to +2.50 D in each eye. 7. The subject must have distance and near visual acuity best correctable to logMAR 0.1 (20/25) or better at both distance and near with subjective refraction for each eye. 8. The subject must read and sign the Informed Consent form. 9. The subject must appear able and willing to adhere the instructions set forth in this clinical protocol. Exclusion Criteria: 1. Has a systemic condition that in the opinion of the investigator may affect a study outcome variable; 2. Participant in unrelated research clinical trial within 30 days prior to enrollment; 3. Known to have any infectious disease (e.g.hepatitis, tuberculosis) or a contagious immunosuppressive disease. 4. Women who are pregnant or lactating or planning a pregnancy at the time of enrollment; 5. Ocular or systemic allergies or disease which might interfere with contact lens wear; 6. Have any systemic disease, autoimmune disease, or use of medication, which may interfere with contact lens wear. This may include, but not be limited to, hyperthyroidism, recurrent herpes simplex/zoster, Sjogren's syndromes, xerophthalmia, acne rosacea, Stevens-Johnson syndromes. 7. Systemic disease or use of medication which might interfere with contact lens wear; 8. Any corneal distortion; 9. Has any known active* ocular disease and/or infection; 10. Is using any systemic or topical medications that in the opinion of the investigator may affect a study outcome variable; and only uses rewetting drops on an occasional basis( greater than 2 times per week). 11. Is a habitual monovision contact lens wearer wearing contact lenses on extended wear basis or for the past 6 months; 12. Diagnosed with Diabetes; 13. Is aphakic; or Has entropion, ectropion, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions. 14. Has undergone refractive error surgery; 15. Has amblyopia or strabismus; 16. Has anisometropia >2 D between both eyes; 17. Has a known sensitivity to the diagnostic pharmaceuticals to be used in the study; 18. Any grade 3.0 or greater slit lamp findings (e.g., edema, corneal neovascularization, corneal staining, tarsal abnormalities, conjunctival injection) on the Efron classification scale, any previous history or signs of a contact lens-related corneal inflammatory event (e.g., past peripheral ulcer or round peripheral scar), or any other ocular abnormality that may contraindicate contact lens wear; 19. Employee of investigational clinic (e.g., Investigator, Coordinator, Technician) |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Johnson & Johnson Vision Care, Inc. |
Canada,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | The Total Grade of Conjunctival Hyperemia | Hyperemia (Redness) was assessed using two different parts of the eye, the Bulbar and the Limbal. Hypemeria was measured using the Efron Scale in 0.5 step units. Grade 0= No Findings, Grade 1= Slight, Grade 2= Mild , Grade 3= Moderate and Grade 4 = severe. Hypermia was assessed in four regions of the eye (Inferior, Nasal, Temporal and Superior). The total grade of Conjunctival Hypermia across all regions and grades is reported. The total grade can range from 0 to 8. Where a higher grade implies worsening conjunctival hypermia | Baseline to 4-Week Follow-up | |
Primary | Upper Lid Margin Staining Score | Upper Lid Margin Staining was assessed using Fluorescein Staining and was measured on the Graded Scale is Grade 0: No Staining is present, Grade 1= 1% to 25% Stains, Grade 2= 26% to 50% Stains, Grade 3= 51% to 75% Stains, Grade 4 76% to 100% Stains. The percentage of eyes with upper lid margin staining for each Grade is reported. | Baseline to 4-Week Follow-up | |
Primary | Average Corneal Staining Area Grade | Corneal staining Area Grade was assessed in throughout five (5) regions in the eye (Central, Nasal, Temporal, Inferior, Superior). Corneal Staining was Graded using the Efron scale from 0 to 4 in 0.1 unit steps and converted to a percentage of region that was stained. The average percent of region that was stained was calculated and reported. | Baseline to 4- Week Follow-up |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05326607 -
Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia
|
N/A | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Completed |
NCT05495971 -
Extended Depth of Focus Contact Lenses for Presbyopia
|
N/A | |
Completed |
NCT05464732 -
Vivity IOL: Emmetropia Compared to Monovision.
|
N/A | |
Recruiting |
NCT06045299 -
Evaluation of the Efficacy and Safety of LNZ101 and LNZ100 for the Presbyopia
|
Phase 3 | |
Active, not recruiting |
NCT04151550 -
Safety & Efficacy of the Laser Scleral Microporation Procedure (Philippines)
|
N/A | |
Not yet recruiting |
NCT05506553 -
Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision
|
N/A | |
Completed |
NCT02554396 -
Evaluation of the Efficacy and Safety of PRX-100 in the Treatment of Early to Moderate Presbyopia
|
Phase 2 | |
Completed |
NCT02235831 -
DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance
|
N/A | |
Completed |
NCT02214797 -
Dispensing Study to Assess Visual Performance of Prototype Contact Lenses
|
N/A | |
Enrolling by invitation |
NCT01443585 -
Clinical Evaluation of a Progressive Addition Lens (PAL)
|
N/A | |
Completed |
NCT01591499 -
Clinical Evaluation of Biofinity Multifocal Compared With Air Optix Aqua Multifocal and With PureVision Multifocal
|
N/A | |
Completed |
NCT04983589 -
A Study to Assess Safety and Efficacy in Participants Age 40 to 55 With Presbyopia (Old Eye) Who Receive AGN-190584 in Both Eyes Twice Daily
|
Phase 3 | |
Completed |
NCT02740010 -
The Visual Performances of a Progressive Multifocal Intraocular Lens With Extended Depth of Focus
|
||
Recruiting |
NCT05796453 -
Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix
|
N/A | |
Completed |
NCT02516306 -
A Study to Evaluate the Safety and Efficacy of EV06 Ophthalmic Solution in Improving Vision in Subjects With Presbyopia
|
Phase 1/Phase 2 | |
Completed |
NCT05359380 -
The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
|
||
Not yet recruiting |
NCT04522427 -
Study of Presbyopia-correcting Intraocular Lenses in Eyes With Previous Corneal Refractive Surgery
|
N/A | |
Completed |
NCT03688425 -
Comparison of Clinical Outcomes POD L GF vs POD F GF in Asian Eyes
|
N/A | |
Recruiting |
NCT06053463 -
Evaluation of Soft Multifocal Lenses in Presbyopic Previous Contact Lens Wearers
|
N/A |