Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to determine if the AcuFocus Corneal Inlay ACI 7000PDT will provide an effective method of for the correction of presbyopia in patients who have normal distance vision but need correction such as glasses or contact lenses to see clearly at near.


Clinical Trial Description

The design and mechanism of action of the AcuFocus™ Corneal Inlay (ACI 7000PDT) is based on the well-established concept of small-aperture optics. In cameras, depth of focus is controlled by reducing the aperture through which light enters; the smaller the aperture, the greater the depth of focus. This concept also applies to the human eye. In the eye of an emmetropic presbyope, the natural lens cannot fully accommodate to focus the light rays from a near object onto a single point on the retina. Thus, a point object is imaged as a blur circle on the retina, and images of extended objects are degraded as well. If an opaque disc with a small aperture in the center is placed in front of the eye, the peripheral rays will be obscured while the central rays pass unaffected. Since peripheral rays enter the eye at a larger angle, they create a larger blur circle at the retinal image plane. Eliminating these peripheral rays reduces the size of the blur circle, improving image resolution.

When the inlay is implanted in one eye, the increased depth of focus provides near and intermediate visual acuity while having a minimal effect on distance acuity. Under binocular conditions, the effect of having an inlay eye with a range of vision from distance to near combined with the uncorrected vision in the fellow presbyopic eye, which will essentially have good distance acuity with reduced near acuity, is similar to the contact lens modality known as "modified monovision."

The ACI is expected to provide presbyopic patients with improvement in near and intermediate vision. ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01352442
Study type Interventional
Source AcuFocus, Inc.
Contact
Status Completed
Phase N/A
Start date May 2011
Completion date March 2014

See also
  Status Clinical Trial Phase
Completed NCT05326607 - Pilot Clinical Investigation of Adaptative Eyeglasses for the Correction of Presbyopia N/A
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Completed NCT05495971 - Extended Depth of Focus Contact Lenses for Presbyopia N/A
Completed NCT05464732 - Vivity IOL: Emmetropia Compared to Monovision. N/A
Recruiting NCT06045299 - Evaluation of the Efficacy and Safety of LNZ101 and LNZ100 for the Presbyopia Phase 3
Active, not recruiting NCT04151550 - Safety & Efficacy of the Laser Scleral Microporation Procedure (Philippines) N/A
Not yet recruiting NCT05506553 - Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision N/A
Completed NCT02554396 - Evaluation of the Efficacy and Safety of PRX-100 in the Treatment of Early to Moderate Presbyopia Phase 2
Completed NCT02214797 - Dispensing Study to Assess Visual Performance of Prototype Contact Lenses N/A
Completed NCT02235831 - DAILIES® AquaComfort Plus® Multifocal (MF) - Comparative Assessment of Visual Performance N/A
Enrolling by invitation NCT01443585 - Clinical Evaluation of a Progressive Addition Lens (PAL) N/A
Completed NCT01591499 - Clinical Evaluation of Biofinity Multifocal Compared With Air Optix Aqua Multifocal and With PureVision Multifocal N/A
Completed NCT04983589 - A Study to Assess Safety and Efficacy in Participants Age 40 to 55 With Presbyopia (Old Eye) Who Receive AGN-190584 in Both Eyes Twice Daily Phase 3
Completed NCT02740010 - The Visual Performances of a Progressive Multifocal Intraocular Lens With Extended Depth of Focus
Recruiting NCT05796453 - Post Market Clinical Follow-up (PMCF) Study of Clareon Vivity & Clareon PanOptix N/A
Completed NCT02516306 - A Study to Evaluate the Safety and Efficacy of EV06 Ophthalmic Solution in Improving Vision in Subjects With Presbyopia Phase 1/Phase 2
Completed NCT05359380 - The Impact of Light Conditions on the Efficacy of Multifocal Intraocular Lens Implantation in Activities of Daily Living
Not yet recruiting NCT04522427 - Study of Presbyopia-correcting Intraocular Lenses in Eyes With Previous Corneal Refractive Surgery N/A
Completed NCT03688425 - Comparison of Clinical Outcomes POD L GF vs POD F GF in Asian Eyes N/A
Recruiting NCT06053463 - Evaluation of Soft Multifocal Lenses in Presbyopic Previous Contact Lens Wearers N/A