Patient Satisfaction Clinical Trial
Official title:
BioHPP Hybrid Prosthesis Versus BioHPP Bar Implant Supported and Retained Overdenture Rehabilitating Edentulous Mandible
The biggest challenge of oral rehabilitation is the replacement of lost structures and the restoration of their function and esthetics, focusing on matching a healthy tooth. Traditional complete dentures, implant (retained, supported) overdentures, and complete implant-supported fixed prostheses are all alternatives to the rehabilitation of the mandibular arch. The aim of this study was to compare BioHPP used as a skeletal substructure for hybrid (implant fixed, detachable) prostheses versus BioHPP bar supporting and retaining by using radiographic tracing to the marginal bone height changes around the implants, patient satisfaction can be improved.
Fourteen completely edentulous male patients were selected from the out-patient clinic, Prosthodontic Department, Faculty of Dentistry, Ain Shams University, according to certain criteria, and they were randomly allocated into two equal groups: group I: the seven patients were rehabilitated by the BioHpp hybrid prosthesis supported on four inter-foraminal implants; group II: While in group II, seven patients were rehabilitated by the BioHpp bar supported and retained overdenture. The upper and lower complete dentures were constructed following conventional methods, and the surgical guide was constructed according to dual-scan CBCT. the four parallel inter-foraminal implants were inserted in the mandible for each patient through used the surgical guide ( flapless technique ) After three months from the first surgery, the final prosthesis was constructed. For Group I; BioHpp fixed hybrid prosthesis, for Group II; BioHpp bar implant-supported and retained complete overdentures were created using digital workflow CAD/CAM. The crestal bone height loss was evaluated after six, twelve, and eighteen months from implant loading by using digital preapical radiography. Also, the patient's subjective evaluations by using a questionnaire based on the visual analog scale including five points (low dissatisfied, dissatisfied, fair, satisfied, highly satisfied) were evaluated for speech, chewing, comfort aesthetic, oral hygiene, and general satisfaction. A comparison between groups I and II was performed by using the Chi-square test, which revealed in the results that group II was significantly lower than group I at all intervals in the mesial and distal surfaces of anterior and posterior implants. Also, the results of the patient satisfaction revealed that, after 6 months, there was an insignificant difference between them as P > 0.05 in all except oral hygiene, as satisfaction was significantly higher in group II than in group I. While, after 12 months, there was an insignificant difference between them all (P > 0.05). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04079543 -
NPO and Patient Satisfaction in the Cath Lab
|
N/A | |
Enrolling by invitation |
NCT05053958 -
Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.
|
N/A | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT04774562 -
The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery
|
N/A | |
Terminated |
NCT04604340 -
Radial Versus Femoral Arterial Access for Cerebral Angiography in Adolescents
|
N/A | |
Recruiting |
NCT04539210 -
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
|
N/A | |
Completed |
NCT02924974 -
Spinal Morphine in Robotic Assisted Radical Prostatectomy
|
Phase 4 | |
Completed |
NCT01052415 -
POL and Access Intervention to Reduce HIV Stigma Among Service Providers in China
|
N/A | |
Recruiting |
NCT06044103 -
Patient-controlled Sedation During Repair of Obstetric Perineal Lacerations
|
Phase 4 | |
Not yet recruiting |
NCT05670080 -
Does MI Have a Therapeutic Role in Arthroscopic Rotator Cuff Repair?
|
N/A | |
Completed |
NCT06114524 -
Effect of Binaural Beats on Level of Anxiety and Toleration in Patients Undergoing Upper Gastrointestinal Endoscopy Without Sedation
|
N/A | |
Completed |
NCT06141122 -
The Colonoscopy Booklet:Effect of a Recipe Resource on Quality of Colonoscopy Bowel Preparation and Patient Experience
|
N/A | |
Not yet recruiting |
NCT04534868 -
Patient Acceptance And Satisfaction of Teledermoscopy In General Practice In a Belgian Rural Area
|
N/A | |
Completed |
NCT04823390 -
Anesthetist Controlled Versus Patient-controlled Sedation: Risks and Benefits
|
Phase 1 | |
Recruiting |
NCT05884684 -
What is the Potential Impact of Reviewing Post-procedure Images With Patients Following Interventional Spine Procedures.
|
N/A | |
Recruiting |
NCT05613439 -
The Fast-track Centre for Hip and Knee Replacement Database
|
||
Recruiting |
NCT06451510 -
Knee Osteoarthritis in the Region of Norrbotten
|
||
Completed |
NCT04420000 -
Effects of Mindfulness Therapy in Patients With Acromegaly and Cushing
|
N/A | |
Withdrawn |
NCT04625842 -
Focus Group Interview Study on Patient Experiences and Satisfaction
|
N/A | |
Recruiting |
NCT04842240 -
Comparison of Patient Reported Outcome Measures Using the BREAST-Q Questionnaire in Patients Undergoing Pre Versus Sub-pectoral Implant Based Immediate Breast Reconstruction.
|