Pancreatic Fistula Clinical Trial
Official title:
Randomized Controlled Trial for Comparison of the Effects of Preventing Postoperative Pancreatic Fistula by With Versus Without TissuePatchTM Cover the Wound Surface of Pancreatic Capsule
Postoperative pancreatic fistula is one of the most serious complications after gastric cancer surgery and can lead to surgery-related death. Postoperative pancreatic fistula for gastric cancer often occurs in accidental injury of pancreas during peripancreatic lymph node dissection, blunt separation of pancreatic capsule injury, laparoscopic instrument clamp and long-term compression of pancreas, etc. TissePatchTM is a synthetic, self-adhesive, absorbable surgical sealant and barrier used to seal and reinforce wounds and prevent leakage of air, blood, and fluid during neurosurgery, spine, chest, and soft tissue surgery. Therefore, we proposed whether the use of TissuePatchTM can reduce the occurrence of pancreatic fistula after gastric cancer surgery, and the clinical trial of the effectiveness of TissuePatchTM on the prevention of pancreatic fistula after radical gastrectomy of gastric cancer can provide new clinical data for the prevention of pancreatic fistula after gastric cancer surgery, and help reduce a series of adverse reactions caused by pancreatic fistula in patients.
Gastric cancer is the fifth most common tumor and the fourth most deadly cancer disease in the world. Surgical resection is the recommended method to cure gastric cancer. In recent years, with the continuous promotion of D2 radical gastrectomy and the rapid development of new technologies such as laparoscopic and robotic surgical systems, although the incidence of complications such as abdominal bleeding, anastomotic leakage and abdominal infection has decreased, but the incidence of Postoperative pancreatic fistula is increasing. Postoperative pancreatic fistula involves the delivery of any measurable volume of fluid through surgically placed drainage tubes, and amylase activity is 3 times higher than the upper limit of normal plasma value. According to the severity of postoperative pancreatic fistula, there are three grades: A, B and C. Grade A pancreatic fistula is mainly biochemical leak (BL), not pancreatic fistula in the real sense. Grade B pancreatic fistula requires a definite change in postoperative treatment strategy, which affects the postoperative process. Continuous drainage of drainage tube in situ for > 3 weeks, or percutaneous or subultrasonic drainage is required; Grade C pancreatic fistula refers to the situation of secondary surgery, single or multiple organ failure (especially respiratory, cardiac and renal insufficiency) and even death caused by postoperative pancreatic fistula. The risk factors of pancreatic fistula after radical gastrectomy for gastric cancer mainly include: 1. Surgical methods and instrument-related factors, such as the scope of surgical resection and lymph node dissection; 2. Pancreatic factors, soft pancreas showed less fibrous tissue, inflammatory cells infiltrating pancreatic tissue and pancreatic edema, and pancreatic fistula was more likely to occur during surgery; 3. Basic information of the patient: obesity is an important risk factor for pancreatic fistula. Currently, laparoscopic surgery has been widely carried out in gastric cancer, but due to the characteristics of laparoscopic surgery and the difference in operator experience, the incidence of postoperative pancreatic fistula is higher than that of open surgery. Postoperative pancreatic fistula is one of the most serious complications after gastric cancer surgery and can lead to surgery-related death. Postoperative pancreatic fistula for gastric cancer often occurs in accidental injury of pancreas during peripancreatic lymph node dissection, blunt separation of pancreatic capsule injury, laparoscopic instrument clamp and long-term compression of pancreas, etc. Due to the digestion of pancreatic fluid, severe pancreatic fistula is often followed by abdominal infection, postoperative bleeding, anastomotic fistula and other serious complications, even life-threatening. Therefore, the prevention and early detection of pancreatic fistula after radical gastrectomy of gastric cancer is very important. At present, there are few studies on the prevention of pancreatic fistula after gastric cancer surgery at home and abroad. The main preventive surgeries require surgeons to perform fine operations and also require individual drainage methods. These methods can reduce the occurrence of pancreatic fistula after gastric cancer surgery to a certain extent, but have weak preventive effect on the large scope of lymph node dissection. TissuePatchTM is a synthetic, self-adhesive, absorbable surgical sealant and barrier used to seal and reinforce wounds and prevent air, blood, and fluid leakage during neurosurgery, spine, chest, and soft tissue surgery. It is a pre-formed patch with built-in adhesive strength. It also incorporates TissuebondTM, a bio-bonding polymer that forms strong covalent bonds to protein-rich tissue surfaces. Adhesion is achieved when the prefabricated membrane is applied to the tissue bed with moderate pressure of 60 seconds, which allows contact adhesion and eliminates potential tissue space. Studies have shown that the use of TissuePatchTM in major neck surgery can effectively prevent the occurrence of chylous leakage and promote the recovery of patients. Therefore, we proposed whether the use of TissuePatchTM can reduce the occurrence of pancreatic fistula after gastric cancer surgery, and the clinical trial of the effectiveness of TissuePatchTM on the prevention of pancreatic fistula after radical gastrectomy of gastric cancer can provide new clinical data for the prevention of pancreatic fistula after gastric cancer surgery, and help reduce a series of adverse reactions caused by pancreatic fistula in patients. Therefore, based on our experience and foundation in the treatment of gastric cancer in gastrointestinal surgery, the real world observation and research on the experimental treatment plan for the prevention of pancreatic fistula in gastric cancer patients after surgery will be carried out, and the integration of domestic superior resources will surely further promote the development of the prevention of pancreatic fistula after radical gastrectomy for gastric cancer. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01696903 -
Evaluation of a Novel Pancreaticojejunostomy Technique for Pancreaticoduodenectomy
|
N/A | |
Completed |
NCT01301222 -
Role of Octreotide in Preventing Pancreatic Fistula After Pancreaticoduodenectomy (PD) in Patients With Soft Pancreas
|
Phase 4 | |
Recruiting |
NCT05155878 -
Prognostic Factors in Periampullary Tumors and Cysts
|
||
Terminated |
NCT03757455 -
ERAS Protocol in Pancreaticoduodenectomy and Total Pancreatectomy
|
N/A | |
Recruiting |
NCT05212350 -
Total pancrEaTectomy vs High-Risk Pancreatic anastomosiS
|
N/A | |
Completed |
NCT04609137 -
Early Drain Removal Versus Standard Drain Management After Distal Pancreatectomy (Early-Dist)
|
N/A | |
Recruiting |
NCT04798560 -
Identifing Risk Factors for Pancreaticojejunostomy Leakage Following Pancreaticoduodenectomy
|
||
Completed |
NCT03627559 -
Early Detection of Anastomotic Leakage by Microdialysis Catheters
|
||
Completed |
NCT01550406 -
Use of Polyethylene Glycolic Acid or Tachocomb to Prevent Pancreatic Fistula Following Distal Pancreatectomy
|
Phase 4 | |
Recruiting |
NCT04783831 -
Biodegradable Pancreatic Stents for the Prevention of Postoperative Pancreatic Fistula After Cephalic Pancreaticoduodenectomy
|
||
Not yet recruiting |
NCT05387538 -
One-layer Versus Two-layer Duct-to-mucosa Pancreaticojejunostomy After Pancreaticoduodenectomy .
|
N/A | |
Active, not recruiting |
NCT02775227 -
HYPAR Trial - Hydrocortisone vs. Pasireotide in Reducing Pancreatic Surgery Complications
|
Phase 4 | |
Completed |
NCT02790333 -
Different Stapler Cartridge For Pancreatic Stump Texture To Prevent Pancreatic Fistula
|
N/A | |
Not yet recruiting |
NCT05657366 -
Peritoneal Lavage on the Incidence of Pancreatic Fistula and Related Complications After Pancreatoduodenectomy
|
N/A | |
Completed |
NCT03419676 -
Use of Hemopatch as a Sealant at the Pancreaticojejunostomy After Pancreatoduodenectomy
|
Phase 3 | |
Recruiting |
NCT05297136 -
Preoperative Endoscopic Pancreatic Stent for Distal Pancreatectomy
|
N/A | |
Completed |
NCT00931554 -
Randomized Trial of Early Versus Standard Drainage Removal After Pancreatic Resections
|
N/A | |
Completed |
NCT00679952 -
Closed Suction Drainage and Natural Drainage of the Pancreatic Duct in Pancreaticojejunostomy
|
Phase 3 | |
Recruiting |
NCT04380506 -
Validations of New cut-of for the Stratification of Postoperative Complications,Drains Management
|
N/A | |
Recruiting |
NCT06283160 -
Metabolomic and Immune Profiling in the Development of Pancreatic Fistulas After Cephalic Duodenopancreatectomy
|