Prospective Clinical Study Using Radiostereometric Analysis (RSA) and DEXA to Evaluate Fixation and Wear of the Restoration ADM Acetabular System
The dual mobility design concept for acetabular liners, as is used in the Restoration ADM Acetabular System, has been applied in various implants since its introduction by Gilles Bousquet in France in 1976. Dual mobility cups have shown good clinical results and have been particularly lauded for low incidence of dislocations. However, the wear performance of this design concept has not been proven to date. As wear particles are a possible contributing factor in aseptic loosening, the assessment of wear and fixation is an important step in proving this implant design. The proposed study will combine RSA and peri-prosthetic bone mineral density as well as outcome questionnaires to provide a complete in vivo evaluation of prosthesis fixation, polyethylene wear, and objective and subjective outcomes for the Restoration ADM Acetabular System.
Question 1: a) Do the implant components of the Restoration ADM Acetabular System achieve adequate fixation to the underlying bone? Null Hypothesis: There is no significant increase in micromotion of the implant components after 1 year indicating adequate long-term fixation at the implant - bone interface. Alternative Hypothesis: There is a significant increase in micromotion of of the implant components after 1 year indicating inadequate fixation at the implant - bone interface. b) What are the migration patterns (translations and rotations) of the Restoration ADM Acetabular System components during the first three years postoperatively? c) For what proportion of implants does migration continue to increase during the three year follow-up? d) Are inducible displacements, measured during weight-bearing follow-up exams, consistent over time and do they indicate that adequate fixation has been achieved? e) Are there significant differences in migration patterns (translations and rotations) between the Restoration ADM Acetabular System components and other implants previously studied with RSA and reported in the literature? Question 2: a) How much does the femoral head wear into the polyethylene liner?b)How much backside wear occurs on the polyethylene liner? c)How does the total wear compare to that with other implants previously reported in the literature? Question 3: Does the polyethylene liner demonstrate mobile bearing properties? Question 4: a) Are there changes over time in bone mineral density of peri-prosthetic bone with the Restoration ADM Acetabular System components? b) Where do changes in bone mineral density occur? Question 5: Does total hip arthroplasty using the Restoration ADM Acetabular System result in significant improvement in health status and functional outcome? ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04657926 -
A Trial of APPA in the Treatment of Knee Osteoarthritis
|
Phase 2 | |
Completed |
NCT02536833 -
A Study Evaluating the Safety, Tolerability, and Efficacy of SM04690 Injected in the Target Knee Joint of Moderately to Severely Symptomatic Osteoarthritis Subjects
|
Phase 2 | |
Completed |
NCT03014037 -
Comparing Mesenchymal Stem Cell Counts in Unilateral vs. Bilateral Posterior Superior Iliac Spine Bone Marrow Aspiration
|
N/A | |
Recruiting |
NCT05937542 -
A Qualitative Investigation of CLEAT Participants
|
||
Completed |
NCT03644615 -
A Mindfulness Program (MBSR) in the Management of Symptomatic Hip and Knee Osteoarthritis
|
N/A | |
Recruiting |
NCT06061367 -
Muscles Strength and Gait Parameteres After TKA
|
||
Withdrawn |
NCT04976972 -
A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation
|
N/A | |
Completed |
NCT05496205 -
A SAD Study to Evaluate the Safety, Tolerability and PK/PD of iN1011-N17 in Healthy Volunteers
|
Phase 1 | |
Completed |
NCT03850665 -
Comparison of Functional Outcome in Patients After Hip Arthroplasty Depending on Surgical Approach
|
N/A | |
Completed |
NCT02826902 -
Effect of Anesthesia on Quality of Recovery in Patients Undergoing Correctional Tibial Osteotomy - A Randomized Controlled Trial
|
N/A | |
Completed |
NCT04402502 -
Dynamic 4DCT to Examine Wrist Carpal Mechanics
|
N/A | |
Completed |
NCT02923700 -
Leukocyte-rich PRP vs Leukocyte-poor PRP for the Treatment of Knee Cartilage Degeneration: a Randomized Controlled Trial
|
Phase 4 | |
Completed |
NCT04564053 -
Study of Safety, Tolerability and Pharmacokinetics of LNA043 in Japanese Osteoarthritis Participants
|
Phase 1 | |
Completed |
NCT05070871 -
A Clinical Trial Investigating the Effect of Salmon Bone Meal on Osteoarthritis Among Men and Women
|
N/A | |
Not yet recruiting |
NCT05036174 -
Diphenhydramine Ointment for Knee Osteoarthritis
|
N/A | |
Recruiting |
NCT02666443 -
Low Dose Dexamethasone in Supraclavicular Blocks
|
N/A | |
Recruiting |
NCT02912429 -
Onlay vs. Inlay Patellofemoral Arthroplasty
|
N/A | |
Active, not recruiting |
NCT02723929 -
Effects of tDCS and tUS on Pain Perception in OA of the Knee
|
||
Terminated |
NCT02820766 -
Journey II BCS CMS Total Knee System Compared to Other PS Total Knee Systems in PT Setting
|
N/A | |
Withdrawn |
NCT02921594 -
Kinematic Comparison of Vanguard XP and Vanguard CR Total Knee Arthroplasties
|
N/A |